Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH • SEWAGE PLAN REVIEW CHECKLIST / 2 /41 Location: A.M. G Lot 73 Zone of Contribution: In y Out Acreage (6 9fi c1 Commer . _ Residential: Street: 20 4 3i et J i4 74;-/ Village: 5 (-(lf'i✓ Floor Plan: w. # Bedrooms: Owner: /c /4520e-i--ti- Installer: , �' ,e at Address: Phone: drnalginlIW '7 Phone: �� Builder: Engineer: /.�' 672-e /gt4W 77 Address: Phone: cV '36) -6 2...3 7 Phone: N/A YES NO 1. Required#of copies received k_------- 2. Date of soils exam and percolation test not older than 2 years i___------"-- 3. 4-5 ._/3. 4-5 ft of naturally occurring pervious material, above water table L---- 4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5. Water line 10 ft from septic components Var.: 6. Benchmark indicated and shown-NGVD if near wetlands k.------ 7. Septic tank minimum 10 ft from foundation, deck Var.: ✓- 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: ..-- 9. Leaching minimum 100 ft from wetlands Var.: 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ,____-- 11. Tank/leaching minimum 10 ft from property line Var.: L.------ 12. 112. System meets all other setback requirements Var.: c____-- 13. Uses adjustment for maximum high groundwater Var.: -- 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: 15. System not in top or subsoil(A,B horizons)or 5' removal 16. Proposed contours are suitable �----- 17. System meets slope requirements-min. 1/8", 'A"preferred i,. ..._- • 18. System meets breakout requirements PVC liner: Wall: L__-- 19. f19. Specified tee sizes are proper, gas baffle on outlet tee ( 20. Sewage is under 10,000 gpd for parcel k____--- 21.No garbage disposal .._-- - 22. System adequately sized for its intended use 23. Minimum 6"stone or compacted below tank and dbox '1/4.----- 24. 1/4.---'24. Manhole covers within 6"of grade, pump chamber cover to grade `----' 25. Inspection port on plastic chambers/leach field C___ - 26. Electrical permit for pump chamber/Separate meter for duplexes --'` - 27. Pump system-2" line,weep hole,check valve,tee in dbox, pump size 28. Septic tank/pump chamber to be factory waterproofed 29. Vent provided if leaching below 3 feet, under driveway/parking ----- 30. Buoyancy calculations for tank/pump chamber ./ 31. Engineer to inspect and certify soils: wall: commercial: ''-- 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature --- 33. H-20 loading is subject to vehicular traffic, groundwater --- 34. 34. Title V Application and permit fee, installer signature ---------" 35. Foundation footing min. 2 feet above adjusted ground water for new house ./ 36. Deed Restriction required max. #bedrooms: max. flow: -7J gpd 37. Check area lots for groundwater/Label groundwater in Assessor's CA.j--- Map Plan reviewed by: " 6/03ro3