Loading...
HomeMy WebLinkAboutEngineer Plan_ FINISH GRADE OVER D -BOX = 52.7'± FINISH GRADE OVER CHAMBERS= 52.4'- 51.4' 'C -OUT FL. EL = 54.311 SLOPE @ 2% MIN. OVER SYSTEM PROVIDE EXTENSION RISER REMOVABLE WATER -TIGHT COVER OVER 314" TO NET DOUBLE WASHED 1. UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION WITH COVER OVER INLET & H-20 RISER TO WITHIN 6" OF F.G. STONE TO CROWN OF PIPE 4" SCHEDULE 40 PVC MIN SLOPE 1°la INSPECTION PORT w/ ACCESS BOX WITH 2" OF 1/8" TO 152" DOUBLE WASHED METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL FINISH GRADE OUTLET TO WITHIN 6" OF F.G. COVER TO GRADE (SEE NOTE #21) CODE AND ANY APPLICABLE LOCAL RULES. L = 54 2'# F.G. OVER TANK EL. = 553.3' } r5" DIA. OUTLET(S) STONE OR GEOTEXTILE FILTER FABRIC -� 2. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH AND THE @ FND. E - DESIGN ENGINEER. TOP of SAS = 49.405 PLACE H-20 RISER 9"MIN. 9" MIN ON CHAMBERS 3. 4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL BE USED IN DISPOSAL SYSTEM UNLESS OTHERWISE NOTED, SCH. 40 PVC 4" PVC TEE 36" MAX. !48.409' 1" MAX. BREAKOUT EL = 48.905 w/PIPED INLETS TO - + WITHIN 6" OF F.G. 4. TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN 3° DROP MAX „ SEWER PIPE L-$ _ o 0 o a 6" 3 3 9 fPROPOSED4" PROVIDE WATERTIGHT ELEVATION = 48.90' FORA DISTANCE OF 15' AROUND THE PERIMETER OF THE SAS, UNLESS A 2 DROP MIN _ nl sioae@ir -- 0 004,0 40 MIL GEOMEMBRANE LINER IS PLACE AT LEAST FIVE FEET FROM S.A.S. AND THE TOP OF 13" 4" PVC IN FROM f JOINTS (TYP.) 0 0 0000 Q D o THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION. 14" SEPTIC TANK O 4' PVC OUT TO -� oo O O I-1 0 5, SLOPE ALL SOLID PIPE AT 1,0% MINIMUM CONTRACTOR TO PROVIDE LEACHING FACILITY 1.00' o0 o o L rJ SPECIFIED DROP BETWEEN o 0 6. THIS SYSTEM IS NOT DESlGNEDFOR A GARBAGE DISPOSAL. INLET AND OUTLET CONTRACTOR CONTRACTOR SHALL 48 8O� MIN 6 48 635 _T- 00 0 0 t 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0� 7, LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO BACK SHALL VERIFY SIZE 48" VERIFY CONDITION OF \ OUTLET TEE 1,00' 000 000 4 0 0 00 00 000 0 00 00 moo 0 0000 00 00 0 0 0O oo 00 FILLING WHEN SYSTEM IS NEARLY COMPLETE AND READY FOR INSPECTION. SYSTEM IS AND CONDITION SIZE EXISTING TEES GAS BAFFLE 6" CRUSHED STONE + oo - NOT TO BE BACK FILLED WITHOUT FIRST OBTAINING APPROVAL FROM BOARD OF HEALTH EXISTING SEPTIC AND REPLACE AS OVER MECHANICALLY 3 25' 3.25' 1 5' 1.y AND DESIGN ENGINEER. TANK NECESSARY COMPACTED BASE 1 6.0' 1018. ELEVATIONS BASED ON APPROXIMATE M.S.L. DATUM. SEE BENCHMARK ELEVATION AS OUTLET DISTRIBUTION BOX 42.5 6.0' SHOWN ON PLAN. TO BE INSTALLED ON A LEVEL STABLE GROUND WATER ELEV.= < 39.00' FIRST TWO FEET OF OUTLET Z46.40' 9. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION BASE. PIPES FI ST LAID LEVEL ; THROUGH DIG -SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT LC -6 CHAMBERS 5 MIN CHAMBER END V{E r` 1 -888 -DIG -SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY DISCREPANCIES EXISTING 1,000 GALLON CONCRETE SEPTIC TANK CROSS SECTION VIEW P AL CHAMBER PROFILE p TO THE DESIGN ENGINEER. TO 10. SEPTIC TANK PROFILE H-20 C HA �, ,7- t -''k ALL JOINTS WHERE PIPE ENTERS AND EXITS CONC. STRUCTURES SHALL BE MADE WATERTIGHT. ' NOT TO SCALE _____ _a...h _ __.:.._ _. i 11. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING NOT TO SCALE NOT TO SCALE r_._. ___:---r_. -_ _._ .:. �_.._.___._. _. - -- ) REGULATIONS. OWNER/APPLICANT lSTOOBTAIN SUCH DETERMINATION FROM TEST PST STA APPROPRIATE AUTHORITY. NOTES: f *., • < PERC NO. N!A t I ,,. 12. ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS LOCATED '.* fi ' INSPECTOR: Phil Renea' d BOH UNDER MORE THAN 3 FEET OF COVER OR LOCATED UNDER PAVEMENT, DRIVES, OR 1.) MAGNETIC MARKING TAPE SHALL BE PLACED ALONG THE TOP EDGE OF t « , EACH SEPTIC SYSTEM COMPONENT. .4 TRAVELED WRVS IN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING. EVALUATOR: Michael Pim ntel EIT CSE 2. CONTRACTOR SHALL VERIFY SOIL CONDITIONS !N rHE LOCATION OF THE C.S.E. APPROVAL DATE: Ct. 27, 1999 13. DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST AND FINES. PROPOSED LEACHING FACILITY TO ENSURE CONSISTENCY WITH TEST PIT • `• .i} DATE: May 13,202' 14. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND UNSUITABLE DATA SHOWN ON THIS PLAN. REPORT TO ENGINEER AND LOCAL BOARD OF Q RQ P® � 8C 10 . �='�` �^` MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF LEACHING FACILITY = _ ,+, TEST PIT #: lower-- �• • . ' MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY, HEALTH IF SOILS ARE NOT _ _ . • . s., --..e ELEV WATER _ P 540` W108 • • r d• `y ELEV TOP - 54.00' FINES OTHER UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CM 15.255(3). 3.) PROPERTY IS NOT LOCATED WITHIN A MASS DEP APPROVED ZONE II. �f r..? - .-,. 1 •.,! r'f •y M;.,,.-' + ►'e - i`',' PERC RATE _ < 2 rit 00 �•• -_ �, • • 15. CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN 4J SWING TIES SHOWN ON THIS PLAN ARE PROVIDED ONLY AS A COURTESY ♦ J • • < 3�in./inch SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK. FOR THE INSTALLER INSTALLER SHALL VERIFY SWING TIE MEASUREMENTS y " .• •,. 16., PROPOSED PROJECT !S LOCATED WITHIN: IN THE FIELD PRIOR TO INSTALLING THE SYSTEM. CONTRACTOR SHALL " ° _ NOTIFY ENGINEER IF MEASUREMENTS APPEAR TO BE INCORRECT. //� • • •~ f TDEXTURAL CLASS:ASSESSOR'S MAP 134 LOT 138 O¢ PPV _ > w e e - *9 z ` RC36 I `� OWNER OF RECORD: LINDA MttLER &LINDA SINGLETON PE " �OG� /'` ¢ `• , *19 POMPANO ROAD 6 4`��' a a ADDRESS: YARMOUTH PORT, MA 02675 DWELLING 3 HC -2 No Mottling, Standing or Weeping Observed /� p� DESIGN DATA I LEGEND ` SAO permit valid for REPAIR OF SEPTIC SYSTEM w - 50x0' EXISTING SPOT GRADE r \i,, f NUMBER OF BEDROOMS (EXISTING) 3 ONLY, due to State and Local septic vuiaucea w_ 'O FL. EL.=54,3'± ( - -_ ._ 0 - - --- EXISTING CONTOUR Board of Health review and approvhl is required for \ NUMBER OF BEDROOMS (DESIGN) 3 5 XIS INC S 'b any future additionslrenovations/attentions to � � 110 GAUDAY/BEDROO M _ PROPOSED CONTOUR sewage facilities and/or structures/dwelling. DESIGN FLOW iQiADESIGN FLOW 330 GAUDAYCC Yamouth Health Department C1 50 PROPOSED POT GRA DE 200 / 660 GAUDAYAPPROVED DESIGN FLOW x r EXISTING UNDERGROUND UTILITIES �O P� E GALLON SEPTI TANK EXIST NG GAS LIN 56 - 4 / - - - _ 2G' � -- USE EXISTING 1,000 LLO C - � GAS ---- I E Due 0 Na 53x3' \ / / /'y` �ej - W - - EXISTING WATER LINE - . _ _ _ _ _ �i 3,, INSTALL (6) LC -6 LEACHING CHAMBERS w/ STONE b h : TEST PIT LOCATION PROPOSED H°20 DISTRIBUTION BOX i / SIDEWALL CAPACITY EXISTING 1,000 GALLON SEPTIC TANK d (2 19 �' / / (LENGTH + WIDTH) (2 SIDES) (2' HIGH) (0:74 GPD/S.F.) = GAUDAY 20" ,(PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE tO \ISTUMP (TPP) / / 3„ 3 v (42.5'+6.0')(2)(2')(0.74 GPD/S.F.) = 143.6 GAUDAY tee« s. {4) 3) i : - y I \ BOTTOM CAPACITY PROPOSED DISTRIBUTION BOX (H-20) j 42.5'/ / (LENGTH x WIDTH) (0J4 GPD/S. F.) = GAUDAY C3 PROPOSED LC -6 LEACHING CHAMBER (H-20) / --52--- (42.5'x6.0') (0.74 GPD/S.F.) = 188.7 GAUDAY 1f _ PROPOSEDf e� p8.00 REV. DATE BY APP'D. DESCRIPTION INSPECTION PORT / TP 1 �} 1 r ,int TOTALS: 13,. ,A5 t5 f / 50�"' 4� 5 - _ S' • TOTAL NUMBER OF CHAMBERS 6 PROPOSED SEPTIC SYSTEM UPGRADE SWING -TIES DESCRIPTION N �O$ooLOCUS HC -2 FEMA FLOOD ZONE X 4950' °' 17. DEED REFERENCE: BOOK 13889, PAGE 190 l CO . • A 61, THIS PLAN IS TO BE USED ONLY FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL k _;0, 0 C, 21. A 4" PERFORATED SCH. 40 PVC PIPE SHALL BE PLACED IN A VERTICAL POSITION TOA Y oNX DEPTH OF THE BOTTOM OF THE SAS AND EXTEND TO WITHIN 3" OF FINISH GRADE. A r 22. OWNER / APPLICANT I CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL •.. REQUIRED PERMITS AND APPROVALS FOR THIS PROJECT. B 36" I 'y'�ly'�`'r3,`- : „/ =n �• • `. . �v. rr3'1E1r?r-ry MAP 134 _ MAP 134 , • ,- LOT 138 Yp LOT 137r. ♦.� ` r t.. y L. C 11,340± S. F. µMQ ` i s,..a y PLAN MAP 134# ` EXISTING �_ T LOCUS LOT 139 3 -BEDROOM h i SCALE: 1" = 1000' 132" DWELLING 3 HC -2 No Mottling, Standing or Weeping Observed /� p� DESIGN DATA I LEGEND ` SAO permit valid for REPAIR OF SEPTIC SYSTEM w - 50x0' EXISTING SPOT GRADE r \i,, f NUMBER OF BEDROOMS (EXISTING) 3 ONLY, due to State and Local septic vuiaucea w_ 'O FL. EL.=54,3'± ( - -_ ._ 0 - - --- EXISTING CONTOUR Board of Health review and approvhl is required for \ NUMBER OF BEDROOMS (DESIGN) 3 5 XIS INC S 'b any future additionslrenovations/attentions to � � 110 GAUDAY/BEDROO M _ PROPOSED CONTOUR sewage facilities and/or structures/dwelling. DESIGN FLOW iQiADESIGN FLOW 330 GAUDAYCC Yamouth Health Department C1 50 PROPOSED POT GRA DE 200 / 660 GAUDAYAPPROVED DESIGN FLOW x r EXISTING UNDERGROUND UTILITIES �O P� E GALLON SEPTI TANK EXIST NG GAS LIN 56 - 4 / - - - _ 2G' � -- USE EXISTING 1,000 LLO C - � GAS ---- I E Due 0 Na 53x3' \ / / /'y` �ej - W - - EXISTING WATER LINE - . _ _ _ _ _ �i 3,, INSTALL (6) LC -6 LEACHING CHAMBERS w/ STONE b h : TEST PIT LOCATION PROPOSED H°20 DISTRIBUTION BOX i / SIDEWALL CAPACITY EXISTING 1,000 GALLON SEPTIC TANK d (2 19 �' / / (LENGTH + WIDTH) (2 SIDES) (2' HIGH) (0:74 GPD/S.F.) = GAUDAY 20" ,(PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE tO \ISTUMP (TPP) / / 3„ 3 v (42.5'+6.0')(2)(2')(0.74 GPD/S.F.) = 143.6 GAUDAY tee« s. {4) 3) i : - y I \ BOTTOM CAPACITY PROPOSED DISTRIBUTION BOX (H-20) j 42.5'/ / (LENGTH x WIDTH) (0J4 GPD/S. F.) = GAUDAY C3 PROPOSED LC -6 LEACHING CHAMBER (H-20) / --52--- (42.5'x6.0') (0.74 GPD/S.F.) = 188.7 GAUDAY 1f _ PROPOSEDf e� p8.00 REV. DATE BY APP'D. DESCRIPTION INSPECTION PORT / TP 1 �} 1 r ,int TOTALS: 13,. ,A5 t5 f / 50�"' 4� 5 - _ S' • TOTAL NUMBER OF CHAMBERS 6 PROPOSED SEPTIC SYSTEM UPGRADE SWING -TIES DESCRIPTION HC -1 HC -2 FEMA FLOOD ZONE X 4950' COMMUNiTYPANEL# 25001CO579J 17. DEED REFERENCE: BOOK 13889, PAGE 190 18, PLAN REFERENCE: PLAN BOOK 207, PAGE 57 4200' 19. ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION. 20. THIS PLAN IS TO BE USED ONLY FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL k _;0, NOT ASSUME ANY LIABILITY FOR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE 21. A 4" PERFORATED SCH. 40 PVC PIPE SHALL BE PLACED IN A VERTICAL POSITION TOA DEPTH OF THE BOTTOM OF THE SAS AND EXTEND TO WITHIN 3" OF FINISH GRADE. A REMOVABLE THREADED CAP SHALL BE PLACED ON THE TOP TO ALLOW FOR INSPECTIONS. 22. OWNER / APPLICANT I CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL REQUIRED PERMITS AND APPROVALS FOR THIS PROJECT. 39.00' DWELLING 3 HC -2 No Mottling, Standing or Weeping Observed /� p� DESIGN DATA I LEGEND ` SAO permit valid for REPAIR OF SEPTIC SYSTEM w - 50x0' EXISTING SPOT GRADE r \i,, f NUMBER OF BEDROOMS (EXISTING) 3 ONLY, due to State and Local septic vuiaucea w_ 'O FL. EL.=54,3'± ( - -_ ._ 0 - - --- EXISTING CONTOUR Board of Health review and approvhl is required for \ NUMBER OF BEDROOMS (DESIGN) 3 5 XIS INC S 'b any future additionslrenovations/attentions to � � 110 GAUDAY/BEDROO M _ PROPOSED CONTOUR sewage facilities and/or structures/dwelling. DESIGN FLOW iQiADESIGN FLOW 330 GAUDAYCC Yamouth Health Department C1 50 PROPOSED POT GRA DE 200 / 660 GAUDAYAPPROVED DESIGN FLOW x r EXISTING UNDERGROUND UTILITIES �O P� E GALLON SEPTI TANK EXIST NG GAS LIN 56 - 4 / - - - _ 2G' � -- USE EXISTING 1,000 LLO C - � GAS ---- I E Due 0 Na 53x3' \ / / /'y` �ej - W - - EXISTING WATER LINE - . _ _ _ _ _ �i 3,, INSTALL (6) LC -6 LEACHING CHAMBERS w/ STONE b h : TEST PIT LOCATION PROPOSED H°20 DISTRIBUTION BOX i / SIDEWALL CAPACITY EXISTING 1,000 GALLON SEPTIC TANK d (2 19 �' / / (LENGTH + WIDTH) (2 SIDES) (2' HIGH) (0:74 GPD/S.F.) = GAUDAY 20" ,(PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE tO \ISTUMP (TPP) / / 3„ 3 v (42.5'+6.0')(2)(2')(0.74 GPD/S.F.) = 143.6 GAUDAY tee« s. {4) 3) i : - y I \ BOTTOM CAPACITY PROPOSED DISTRIBUTION BOX (H-20) j 42.5'/ / (LENGTH x WIDTH) (0J4 GPD/S. F.) = GAUDAY C3 PROPOSED LC -6 LEACHING CHAMBER (H-20) / --52--- (42.5'x6.0') (0.74 GPD/S.F.) = 188.7 GAUDAY 1f _ PROPOSEDf e� p8.00 REV. DATE BY APP'D. DESCRIPTION INSPECTION PORT / TP 1 �} 1 r ,int TOTALS: 13,. ,A5 t5 f / 50�"' 4� 5 - _ S' • TOTAL NUMBER OF CHAMBERS 6 PROPOSED SEPTIC SYSTEM UPGRADE SWING -TIES DESCRIPTION HC -1 HC -2 CORNER OF STONE (1) 15.0' 72.1' CORNER OF STONE (2) 46.1' 42.6' CORNER OF STONE (3) 48.4' 48.1' CORNER OF STONE (4) 21.0' 75.5' PROPOSED (6} LC 6 ! ' 56 - -. -_ __ _. TOTAL LEACHING AREA 449.1 SQ.Fr. _/ ,H °F "+4s PREPARED FOR: CHAMBERS (H-20) wl STONE-/ TOTAL LEACHING CAPACITY 332.3 GALJDAY¢"` sgcy 24" .: �''; _� JOHN �� ROBERT B. OUR CO., INC. MAP 134 o CH JR. JR. , LOT 135 U CI ti N0.! 8066 j LOCATED AT Benchmark i 48 _.. Nail Set in 7" Tree - Elev. = 50.00' Approx, MSL RESERVED FOR BOARD OF HEALTH USE SITE PLAN SCALE: 1" = 10' 19 POMPANO ROAD r YARMOUTH PORT, MA 02675 SCALE: 1 INCH = 10 FT. DATE: MAY 26 2021 0 10 20 40 80 FEET OF ycs PREPARED BY: oo cHu CH L. - JC ENGINEERING, INC. NO°41807 2854 CRANBERRY HIGHWAY EAST WAREHAM, MA 02538 508.273.0377 ' Drawn By: MCP Designed By MCP Checked By JLC JOB No. 5721