HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. L3I 137 Lot Zone of Contribution: In Out X Acreage 4i, 2/3 S F
Commercial: Residential: X
Street: 3 9 C f2-r - Co A1/4
Village: 2t -4tac, Floor Plan: ✓ #Bedrooms:
Owner: C&oi F kG„v P€-2`' Installer: CII l
Address: 238 Sr. Phone: S-e,9 39 8 Z 1 l
Phone: f/,,t-yr.,-9 c g-i k A
rug 22 e5 1`1"v'7
Builder: Engineer: v C2
Address: Phone: $c'e 3 (,Z `f r`/ I
Phone:
N/A YES NO
1.Required#of copies received
2.Date of soils exam and percolation test not older than 2 years ✓
3. 4-5 ft of naturally occurring pervious material, above water table
4. Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5. Water line 10 ft from septic components Var.:
6. Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.: E-k'sr
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: V
9. Leaching minimum 100 ft from wetlands Var.:
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: V
11.Tank/leaching minimum 10 ft from property line Var.:
12. System meets all other setback requirements Var.:
13. Uses adjustment for maximum high groundwater Var.: /
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.:
15. System not in top or subsoil(A,B horizons)or 5' removal
- 16.Proposed contours are suitable ✓
17. System meets slope requirements-min. 1/8", %"preferred V
18. System meets breakout requirements PVC liner: Wall: V✓
19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel
21.No garbage disposal r/
22. System adequately sized for its intended use y/
23.Minimum 6"stone or compacted below tank and dbox ✓
24. Manhole covers within 6"of grade,pump chamber cover to grade V
25.Inspection port on plastic chambers/leach field v
26. Electrical permit for pump chamber/Separate meter for duplexes V
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size ✓
28. Septic tank/pump chamber to be factory waterproofed
29. Vent provided if leaching below 3 feet,under driveway/parking •
30. Buoyancy calculations for tank/pump chamber ✓
31. Engineer to inspect and certify soils: wall: commercial:
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature V
33. H-20 loading is subject to vehicular traffic, groundwater f
34. Title V Application and permit fee, installer signature
35.Foundation footing min. 2 feet above adjusted ground water for new house ✓
36.Deed Restriction required max. #bedrooms: max. flow: gpd ✓
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: .S.- 7 1-e--"-) A . tf1 +'S 6 03,03