HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH _� ��` /,
- SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. X Lot XI Zone of Contribution: In Out Acreage a-). 'kt-
'9-'1
l Commercial: Residential:
Street: ,F 7 3
Village: W
Floor Plan: ✓ #Bedrooms:
Owner: It Ke./S' Installer: "t61/1
Address: Phone:
Phone:
Builder: Engineer: v ��� J/
Address: Phone: "j--' - %r7,%-;;7-; -G i --29.)-2-,
Phone: - l) w c.)6 c,ic.62/
- 4 /C.____
N/A YES NO
1. Required#of copies received k_,-----
2.
/2. Date of soils exam and percolation test not older than 2 years
k...---
3.4-5 ft of naturally occurring pervious material, above water table "1/4._.---
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5. Water line 10 ft from septic components Var.: �---.
6. Benchmark indicated and shown-NGVD if near wetlands ;
7. Septic tank minimum 10 ft from foundation, deck Var.: t
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: t..------
9.
/9. Leaching minimum 100 ft from wetlands Var.: ....._---
10.
i10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ../
11. Tank/leaching minimum 10 ft from property line Var.:
12. System meets all other setback requirements Var.: t/
13. Uses adjustment for maximum high groundwater Var.: (.....----
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: .._...---
15. System not in top or subsoil(A,B horizons)or 5' removal .1/4-----
16.Proposed contours are suitable t_-/-
17. System meets slope requirements-min. 1/8", '/<"preferred k.-------
18.
./18. System meets breakout requirements PVC liner: Wall: L-----
19.
l19. Specified tee sizes are proper, gas baffle on outlet tee L..- -
..20. Sewage is under 10,000 gpd for parcel i-----
21.
./21.No garbage disposal C..----
22. System adequately sized for its intended use
23. Minimum 6"stone or compacted below tank and dbox (-------
24.
--/24.Manhole covers within 6"of grade,pump chamber cover to grade 1/4------
25.
�25. Inspection port on plastic chambers/leach field ....---
26. Electrical permit for pump chamber/Separate meter for duplexes
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size ___.----
28.
28. Septic tank/pump chamber to be factory waterproofed
29. Vent provided if leaching below 3 feet, under driveway/parking
30. Buoyancy calculations for tank/pump chamber /"
31. Engineer to inspect and certify soils: wall: commercial: _.----
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature ------
33.
33. H-20 loading is subject to vehicular traffic,groundwater _/-
34.
34. Title V Application and permit fee, installer signature
C_____2;
35. Foundation footing min. 2 feet above adjusted ground water for new house _,----
36. Deed Restriction required max. #bedrooms: max. flow: gpd
37.Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: 6/03/03