Loading...
HomeMy WebLinkAboutEngineer PlanLEGEND Vr ttL3 PROPOSED CONTOUR 9$ PROPOSED SPOT ,GRADE EXISTING CONTOUR x 99,82 EXISTING SPOT GRADE ---_yy-- EXISTING WATER SERVICE ® TEST PIT PROP. 40 MIL POLY` LINER SEi SET 5' OFF S 4 S, E!.: 99,6-96-9 04'4'42'1 5OW ' 85,50' OQ st do 7 i o 7r 7 STRIPOUT 1\ See Note 77 epi \\\(7 / 13 ✓4 4 / nit valid for REPAIR OF SEPTIC SYSTEIt) E1 �'� LY, due to ' a.d Local septic variancr'i. N rd of Health rc and approval is requi any future ads i /renovations/alteratiaua r- age facilitie., ..ad/ov'iructures/dwelling. o .h 7Dr9 �'A/ YYY Yarmouth Health Department ' Z No. 220 AIPPR®VED � Bev IF 1 5TY. WD. PRM," I , �� 3 371 T,tl.F, m 100,98' F" 701 1 BENCHMARK: C�/DI APN 48-104 ELEVATION = 10 .0' (ASSUMED DAT } 85.00' P 100 y� 70 -7 ..... IC9CT 71)d . k. 1 yb, 7. WI SLI.IVV GRAY ROAD 7HEALTHGDEPT. LIa EXISTING CESSPOOL TC be pumped &,,fined with sorld PROPOSED SEPTIC TANK/ PUMP CHAMBER UNIT SEWER CONNECTION INV.--9S.37E Ur RICHARD J. HOOD No. 35031 U PETER T. "✓\ McENTEE `�' CIVIL `^ _ No. 35109 / d-7 ESTATE OF WALTER J. THOMPSON C,70 MARK & DONNA TRIPP 401 PRENTICE STREET HOLLISTON, MA 01746 I RUCK ISLAND R6 MAP N.T F' GENERAL NOTES: 'I. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER, 2, ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE, ENVIRONMENTAL CODE, TITLE V AND ANY APPLICABLE LOCAL RULES AND RIf.GUI,ATIONS, ECEPT AS REQUESTED BELOW: — 310 CMR 15.405(1)(a)&(b), CONTENTS OF LOCAL UPGRADE APPROVAL: 1, A 3' vancnae, Septic Tank to crawl apace, for a 7' setback. 2, A 1' reduction to the required b sepataion between rnoxirnurn 5¢u:onai h4gn groundwater elevation and bottom of S.A.S., Por a 4' @epurotkon. 3. THE SEWAGE DISPOSAL SYSTEM '.,HALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. h. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. `i, ALL. ELEVATIONS BASE[) ON ASSUMED DATUM. b. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE. CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. THERE ARE NO PRIVATE WELLS LOCATED WITHIN 100' OF IHE S.A.S. 9, ALL. AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 10, IT SHALT. RE THE RESPONSIBILITY OF TIME CONTRACTOR TO VERIFY THE'. THE LOCA'T'ION OF ALL UNDERGROUND UTILITIES PRIOR TO BEGINNING CONSTRUCTION. 11, WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND F'OR 5 FT. ON ALL, SIDES OF THE SAS, AND REPLACE WITH CLEAN FILL AS SPECIFIED IN 310 CMR 255(3) 12, THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE. CONSIDERED A PROPERTY LINE SURVEY, PROPOSED SEPTIC SYSTEM UPGRADE PLAN 220 WINSLOW GRAY ROAD, SO. YARMOUTH, MA repared for: Mark & Donna Tripp, 401 Prentice St., Holliston, MA 01746 Engineering by: Surveying by: SCALE DRAWN JOB. N0. Engineering Warka HOOD 5URVE'Y GROUP 1"=20' P.T.M. 102-07 12 West Crossfield Road 18 Route 6A DATE CHECKED SHEET NO. Forestdole, MA 02644 Sandwich, MA 02563 (508) 477-5313 (508) 888-1090 1/20/07 _PJ.M. 1 01 3 ELEV. TOP PROVIDE 20" RISER WITH WATERTIGHT FAME AND COVER OVER INLET, FOUNDATION OUTLET & PUMP CHAMBER. FRAME AN COVER SHALL BE MADE OF A UURABLF. MATERIAL AND BE SECURED 0 PREVENT UNAUTHORIZED ACCESS (Existing) AS SPECIFIED IN 310 CMR 15.228(2) & 15.231(5). =100,96±� F.G.EL: 100.0± F.G.EL:100.0± 4 4 w Y DRAWL SPACE p' 4" SCH40 PVCIA S= 2Ye (MIN.) 1b„7 10^ INV. -98.10 PROVIDE COUPLING 1±FT. FROM HOUSE INV, -98.37± TEE'S ARE TO BE 4" SCH 40 PVC 8 1 111 11 \ --INV.=97.85± BOTTOM f� ' - 1 INV. -97,85 ZABEL FILTG _h (See Pump Detoil, NOTES; 1) CONTRACTOR SHALL VERT 2) SEPTIC TANK/PUMP CHAT MECHANICALLY COMPACTS 15.221(2). 3) INSTALL INLET & OUTLET 4) EFFLUENT FILTER AND PI MODEL FD C-4 R STARTER SMALL RIB LARGE RIB LIMA n MODEL FD C-4 E MIDDLE/END SMALL RIB LARGE d(.JklG.1A rRIB 1 14� 1kU w � I ,ULTCC CONTACTOR FIELD DRAIN C-4 CHAMBER STORAGE = 7.692 CF/rl 1Ll CONTACTOR FIELD DRAIN C -4H0 HEAVY OUTy UNIT} ARf MARKED NTH Ar COLLA CULTEC, Inc. PH: (203) 775-4416 P.O. Box 280 PH: (800)4-CULTEC 978 Federal Road FX: (203) 775-1462 WWW.CUItep.COm gA.'taC eat 3 of 3) F.G. EL; 101.0± INV.=99 ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION. R & D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A EIX INCH CRUSHED STONE BASE, AS SPECFIFIED IN 310 CMR. ES AS REQUIRED. OUTLET TEE SHALL. HAVE AN EFFLUENT FILTER SHALL BE SERVICED ANNUALLY. D -80X TEE SHALL NOT EXTEND BELOW FLOW LINE NOTE: TO PREVENT BREAKOUT, A 40 MIL POLY LINER SHALL BE PLACED 5' OUTSIDE THE S.A.S. AS SHOWN ON THE PLAN AND SET BETWEEN EL.99.6-96.9 FINISH GRADE=100.6±-\ MAINTAIN 27 MIN SLOPE OVER LEACHING AREA 0 S= I% (MIN.) INV.ELEV.=99.15 MAX. COVER OVER SA.S. - 36" INSPECTION PORT TO BE PLACED ON END UNIT CULTEC. NO. 410 FILTER FABRIC 12" MIN TOP OF CHAMBER ELEV.=99.57 INV.ELEV,=99.15 BOTTOM ELEV.=98.9 -- 4' MIN. ABOVE BOTTOM OF T.P. EXCAVATION OR G.W. MSHGW EL: 94.9 SEPTIC SYSTEM PROFILE N,LS. % SOIL. LOG INSPECTION PORT DATE: JANUARY 11, 2007 SOIL EVALUATOR: PETER McENTEE PE WITNESS: AMY VonHONE HEALTH AGENT Elev. TP Depth 100.0 0" EC ContactorO and Recharger® Sep0c and Stormwater Chamber's A LOAMY SAND 99.3 IOYR 4/1 81, 8 LOAMY SAND 10YR 5/8 27" ESTABLISH VEGETATIVE COVER BACKFILL WITH CLEAN SAND (NATIVE OR_PERC SAND) J BREAKOUT �rELEV.=98.9 EXISTING SUITABLE 48" (TYPICAL) 6" MATERIAL EFFECTIVE WIDTH -13.0' USE 3 ROWS OF 3-CUL7EC C-4 FIELD DRAIN UNITS 4 WITH 6" SEPARATION BETWEEN EACH ROW & NO STONE SOIL A650tRP-T ION $YST M (SECTION %t9. DESIGN CRITERIA NUMBER OF BEDROOMS: 3 BEDROOM SOIL TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE; t5 MIN/IN DAILY FLOW: 330 G,P.D. DESIGN FLOW: 330 G.P.D. GARBAGE GRINDER; NO PROPOSED SEPTIC TANK/PUMP CHAMBER: 1500 GALLON/ 500 GALLON. LEACHING AREA REQUIRED: (330) = 445.9 S.F. .74 BOTTOM AREA: (GENERAL USE APPROVAL FOR 6.7 SF/LF OF C-4 UNIT) MED, SAND 3 UNITS x 8.0'/UNIT 24.0 FT 2.5Y 6/4 3 ROWS x 24.0' x 6.7 SF/LF = 482.4 SF DESIGN FLOW PROVIDED: 0.74(482.4 S.F.) = 357.0 G.P.D. 94.9 (ADJUSTED G.W. 92.9 (STANDING G.W. 5,Z;q 85" 92.0 i ' 96" STANDING G.W. 0 85" PERC RATE G2 MIN/IN, (°C" HORIZON) (MIW 29 -DEC 2006 WATER. LEVEL=8.7) G.W. ADJUSTMENT=2.0 PROPOSED SEPTIC SYSTEM UPGRADE PLAN 220 WINSL.OW GRAY ROAD, SO. YARMOUTH, MA ming by: I Surveying by: SCALE DRAWN dwo. Nu. Is III Workir N00D SURVEY CROUP 1'=20' P.T.M. 102-07 DATE CHECKED SHEET N0. A CroaePield flood iaie, MA 02644 18 .Route 6A Sandwich; MA 02563 477-5313 (508) 888-1090 1/20/07 P,T.M. 12 of__3 INSTALL 1' PVC CONDUIT TO HOUSE FOR WIRING WITH WATERTIGHT JOINTS. WIRE HIGH WATER ALARM FLOAT TO GP 2000 HIGH WATER ALARM PANAL ON CIRCUIT SEPARATE FROM CIRCUIT TO THE PUMP. HOISTING CABLE 709 STAINi 1/8" DIAMETER. / 1,760 LB. PC INV.(IN)=97.85 ALARM ON EL: 95.85 PUMP ON EL: 95.19 BOTTOM OF PUMP OFF EL: 94,52 PUMP CHAMBER s ELEV.= 93.52 PROVIDE 2— WIDE ANGLE FLOATS: FLOAT N0.1: PUMP ON/OFF(BARNES 073618) FLOAT NO.2: ALARM ACTiVA ON (BARNES 073612) PUMP CHAMBER, PUMP & ACCESSORIES AVAILA THROUGH WIGGEN PRECAST CORP., BOURNE MA. PUMP At ACCESSORIES AVAILABLE THROUGH WILLIAMSON E PUMP DETAIL 3 - 20" Dia. Cavan O q O PLAN 6" Dia, 0 NOTES: 1. UNIT SHALL BE SEALED, WRAPPED & MADE WATE 2. ALL PIPING JOINTS SHALL BE MADE WATERTIGHT. 1500/500 GALLON CAPACITIES (H-10) SEPTIC TANK/PUMP CHAMB N.T.S. • PROVIDE WATERTIGHT CONCRETE RISER WITH SECURED COVER TO GRADE NEMA 4 JUNCTION BOX CORROSION RESISTANT & UQUID—TIGHT CABLE CONNECTORS SUPPORTED BY 1-1/4" PVC CONDUIT, JOINTS TO BE MADE WATERTIGHT �2"BALL VALVE w/ UNIONS SCH. 80 PVC GEORGE FISHER CO. MODEL NO. 560 2"SCH. 40 DISCHARGE TO D—BOX .2"SCH. 40 TEE w/ CLEAN—OUT CAP PROVIDE 1/4" WEEP HOLE IN DISCHARGE PIPE FOR SELF—DRAINING FORCE MAIN `2" BALL CHECK VALVE SCH. 80 PVC 100 P,S.I, FLOWMATIC MODEL No, 2085 � 2" SCH. 40 PVC DISCHARGE PIPE ` BARNES SEV412 PUMP .5 H,P. 115 V 2" DISCHARGE PASSING 2" SOLIDS A UNIT 564-6774 (781) 444-6800 Outlets &I S.A.S. LAYOUT — 21" 6-4" POLYSEAL OUTLETS 2" - 2" 1-4" POLYSEAL INLETS LIn �O Lni d a0 Top View Section D -BOX BUOYANCY CALCULATIONS Septic Tank[Pump Chamber Unit BOTTOM OF PUMP CHAMBER EL,= 93.52 ADJUSTED HIGH GROUNDWATER EL.=94.90 BUOYANCY FORCE PER FOOT OF DEPTH: 6.67' x 12.17' x 1,0' x 62.4 Ibs/cu.ft. = 5,065.3 lbs/ft MAXIMUM DISPLACEMENT = 94.90-93.52= 1.38' MAX. UPLIFT PRESSURE = 1.38' X 5,065.3 Ibs/ft = 6990.1 Ibs. WEIGHT OF EMPTY PUMP CHAMBER = 20,088 lbs. 20,088 lbs. > 6990 lbs. O.K. DOSING & STORAGE REQUIREMENTS DAILY FLOW: 330 GPD DOSING REQUIRED: CYCLES/DAY2 5 S 330GALLLONS/CYCLE DISTANCE REQUIRED BETWEEN PUMP ON AND PUMP OFF FLOATS: 82.5 GAL/CYCLE - 125 GAL/FT = 0,66 FT/CYCLE (8"') STORAGE REQUIRED ABOVE WORKING LEVEL: 330 GALLONS STORAGE PROVIDED: INV.(IN) EL:97.85 - PUMP ON EL:95.19 = 2,66' STORAGE PROVIDED = 2.66' X 125 GAL/FT = 332,5 GALLONS PROPOSED SEPTIC SYSTEM UPGRADE PLAN 220 WINSLOW GRAY ROAD, SO. YARMOUTH, MA Prepared for: Mark & Donna Tripp, 401 Prentice St., Holliston, MA 01746 Engineering n ISCALE DRAWN JOB. NO ee►IngiYwAs HOOD SMVEY CROUP No. P20 P,T.M. I STY. it Crossfield Roatl tale, MA 02844 WD. FRM. pATE T.O.F. = 100.96' SHEET' N0. 477-5313 888-1090 .. ..., . ._... ��._,. _ ..........F i S.A.S. LAYOUT — 21" 6-4" POLYSEAL OUTLETS 2" - 2" 1-4" POLYSEAL INLETS LIn �O Lni d a0 Top View Section D -BOX BUOYANCY CALCULATIONS Septic Tank[Pump Chamber Unit BOTTOM OF PUMP CHAMBER EL,= 93.52 ADJUSTED HIGH GROUNDWATER EL.=94.90 BUOYANCY FORCE PER FOOT OF DEPTH: 6.67' x 12.17' x 1,0' x 62.4 Ibs/cu.ft. = 5,065.3 lbs/ft MAXIMUM DISPLACEMENT = 94.90-93.52= 1.38' MAX. UPLIFT PRESSURE = 1.38' X 5,065.3 Ibs/ft = 6990.1 Ibs. WEIGHT OF EMPTY PUMP CHAMBER = 20,088 lbs. 20,088 lbs. > 6990 lbs. O.K. DOSING & STORAGE REQUIREMENTS DAILY FLOW: 330 GPD DOSING REQUIRED: CYCLES/DAY2 5 S 330GALLLONS/CYCLE DISTANCE REQUIRED BETWEEN PUMP ON AND PUMP OFF FLOATS: 82.5 GAL/CYCLE - 125 GAL/FT = 0,66 FT/CYCLE (8"') STORAGE REQUIRED ABOVE WORKING LEVEL: 330 GALLONS STORAGE PROVIDED: INV.(IN) EL:97.85 - PUMP ON EL:95.19 = 2,66' STORAGE PROVIDED = 2.66' X 125 GAL/FT = 332,5 GALLONS PROPOSED SEPTIC SYSTEM UPGRADE PLAN 220 WINSLOW GRAY ROAD, SO. YARMOUTH, MA Prepared for: Mark & Donna Tripp, 401 Prentice St., Holliston, MA 01746 Engineering n ISCALE DRAWN JOB. NO ee►IngiYwAs HOOD SMVEY CROUP N.T.S. P,T.M. 102-07 it Crossfield Roatl tale, MA 02844 18 Route 8A Sandwich, MA 02583 1(508) pATE CHECKED SHEET' N0. 477-5313 888-1090 1/20/07 P.T.M. 3 Of 3