Loading...
HomeMy WebLinkAboutNot Approved - Engineer Plan 2020UNCLE ROBERTS COVE N awl, STONE �b SALT MARSH BENCHMARK: 2EL.=2.8 NAVD 88 - -'� TOP OF STONE BOUND �/ ' ---- 4. /or �' - MPRSN. - alr, �-tSOT50M OF S�-OQ6 ELECTRIC BOX HEALTH CODE VARIANCE TOWN OF YARMOUTH HEALTH REGULATION 3.7 - DISTANCES AND LOCATION OF DISPOSAL FACILITIES: 1. TO ALLOW A VARIANCE OF 18 FT. FROM THE 150 FT. REQUIRED SETBACK BETWEEN A POTABLE WELL AT # 6 SMITHS POINT ROAD ( APPLICANT LOCUS) AND A SOIL ABSORPTION SYSTEM LOCATED ON AN APPURTENANT SEPTIC SYSTEM LOT 107 THAT SERVES # 6 SMITHS POINT ROAD (LOCUS); 132 FT. IS PROVIDED. 2. TO ALLOW A VARIANCE OF 4 FT. FROM THE 150 FT. REQUIREMENT BETWEEN THE POTABLE WELL AND A SOIL ABSORPTION SYSTEM LOCATION ON AN ADJACENT PROPERTY AT 53 UNCLE ROBERTS ROAD; 146 FT. PROVIDED LIMIT OF LAND SUBJECT TO COASTAL all, STORM FLOWAGE AND TOP OF COASTAL BANK EL = 13 NAVD88 10" i i i BANK Top of 1./iO - I, D r LAWN / I / POPLAR POP / 14 -C a 20" POPLA / EE PLANTING NOTES FOR o 50' FROM LIMIT OF J / / HATCHED ZONE g I \� \ COASTAL BANK N � , BOULDER MH A _ V EEK DIST' 1 / OAK /0�Q-- 6 - / 12" OAK \ _ _ s .. .. . .e2'f' . D I . WAY .\ � �� � L=149.59 + .. . ; ✓i Z / ` �' Q \ o \ / CRUSHED STONE PROP0��0���CRUSHED s•UR�FACE �G / 0 DRIP EDGE / OSE Zvi Nb d CB PC, �� MAT �LVEgyEMENT FIND UTILIt gB 100 YR i / FND / 1 FLOOD 3 �LA RF / S � 6 P P�MEN� OF P i TOP OF FOUNDATION 6' OF 3/4" TO __ 1-1/2- DIA. STONE �' BELOW TANK NOTE: ALL PIPE TO BE 4" DIA. PVC TIGHT JOINT WITH MINIMUM SLOPE OF 1/8" PER FT. PROPOSED SEPTIC TANK PRECAST REINFORCED CONCRETE CAPACITY: 1500 GALLONS SET TO EXIST. ELEV. 20 10 0 PLAN 20 1 inch = 20 ft MINIMUM D -BOX INSIDE DIMENSIONS 12•x12' EXISTING "D" BOX SERVING AS MANHOLE ACCESS 60 I S411 IV 'A \ikn. Y I�ILP e0 LOT 107 LP 2 EXIST. LEACH PITS PER AS-BUILTPLAN / MINIMUM D -BOX INSIDE DIMENSIONS IZA2' D -BOX INV. EL. AS EXISTING PLAN TIC SYSTEM PR NO SCALE PROVIDE ACCESS COVERS TO WITHIN 6. OF GRADE LEACH PITS (2 EXISTING) \�RFI� lq4 �s�9,o O / <0 J REP S I� \ /928 EX. SEWER MANHOLE DOOR SILL' \yy\HOLL =17.7 A LAWN EXISTING WELL TO FOUNDATION CB \� FIND \ .n �o \ yP5 0 I WELL 1 #53 \ I UNCLE ROBERTS ROAD \ I \\ I I �I I� / L=10.97' \ \ CB / FND / 6 / LLJI � o oT / O / CL_ d / J \ / Z / O 1 I / WELL / / I \ � I I RESTORATIVE PLANTING • GENERAL DESCRIPTION: • RESTORATION OF THE HATCHED AREA TO THE NORTH OF THE PROPOSED DRIVE SHALL BE TREATED AS DESCRIBED BELOW. • THE SPECIFIC PLANT SPACING FOR SHRUBS SHALL BE CONSISTENT WITH THE SCALED PLAN AND IN ACCORDANCE WITH NORMAL NURSERYMENS' PRACTICE TO ACHIEVE AN INITIAL SUITABLE DENSITY OWING TO THE PROSPECT OF PROPER GROWTH FOR PLANTS FILLING IN . SEVERAL GROUPINGS OF SUCH NATIVE, SHRUBS AS NORTHERN BAYBERRY (myrica pensylvanica), AND BEACH PLUM ( Prupis maritima) ARE PROPOSED. •SHRUB SIZE SHALL BE NO LESS THAN 3 GALLON LOCUS • WITH THE INVASIVE VINES AND GROUNPCOVER REMOVED, PLANTING HOLES SHALL BE PROPERLY PREPARED IN ACCORDANCE' WITH STANDARD LANDSCAPE PRACTICE. • PROVIDE WATER AT REGULAR INTERVA�S TO ALL PLANTINGS. DEEP WATERING IS RECOMMENDED FOR THE FIRST 4 WEEKS, AND APPROX.11) OF WATER PER WEEK DURING THE FIRST GROWING SEASON. • THE GROUND AREAS TO BE RESTORED SHALL BE SET WITH THE SHRUB GROUPINGS AS DECSRIBED ABOVE AND HEAVILY SEEDED ( RAKED IN) WITH A NATIVE FESCUE (any of the native Festuca) MIX IN ADDITION TO SWITCH GRASS (PLANTS OR SEED - Panicum vergatum), AND LTTLE BLUESTEM Schizachyrium scoparium. AREAS INTENDED FOR RESTORATIVE GRASS COVER SHALL BE LIVER -SEEDED IN COMBINATION WITH ROOTED GRASS PLANTINGS AT A MAXIMUM 0.. SPACING OF 12 INCHES. • GRASS PLANTING AND SEEDING SHALL E DONE AT THE RECOMMENDED TIME OF YEAR FOR THE VARIOUS SPECIES. FOLLOWUP INSPECTION IS REQUIRED TO ESTABLISH THE THICK GRASS COVER. SITE NOTES 1. ZONING CLASSIFICATION -R-8 CLUSTER SUBDIVISION SPECIAL PERMIT N0.2829, AUGUST 19.1991 2. PARCEL AREA 2.6 AC. 3. A PORTION OF LOCUS IS WITHIN FEMA FLOOD ZONE AE W1 BFE =13 AS SHOWN ON THE YARMOUTH FIRM PANEL 25001C 07821 4. ELEVATIONS REFER TO NAVD88 5. PLAN REF.: LAND COURT PLAN 4075-P LOT 106 6. ON-SITE SURVEY PERFORMED IN JULY 2017 LEWIS BAY KEY MAP NO SCALE NANTUCKET SOUND YARMOUTH, MA GENERAL WORK NOTES 1. ELEVATIONS REFER TO NAVD88. REFER TO THE BENCHMARK : A STONE BOUND ALONG THE NORTHEAST PROPERTY LINE. CONTACT CAPE COD ENGINEERING, INC. FOR ADDITIONAL ELEVATION INFORMATION. 2. THE SITE WORK IS SUBJECT TO MASS DEP WETLAND ACT AND YARMOUTH WETLAND BY-LAWS. REFER TO THE ORDER OF CONDITIONS ONCE ISSUED. REFERENCE IS MADE TO SPECIAL PERMIT # 2829 ISSUED FOR THE "SMITHS POINT CLUSTER SUBDIVISION, AUGUST 19, 1991"; FURTHER REFERENCE IS MADE TO ANY SPECIAL PERMIT ISSUE FOR THIS SPECIFIC RAZE AND REPLACE PROJECT ONCE ISSUED. 3. PLAN REFERENCE: TOPOGRAPHIC SURVEY DATA PROVIDED BY SCHOFIELD BROTHERS OF CAPE COD, INC. SEPTIC SYSTEM AND WATER SUPPLY DETAILS ARE DERIVED BY CAPE COD ENGINEERING, INC. FROM IN -GROUND RESEARCH AND RECORD AS -BUILT INFORMATION. 4. THE SITE IS IMPACTED BY THE AE FLOOD ZONE TO THE ELEV. = 13 CONTOUR. 5. EXISTING OFF SITE WATER SERVICE IS ADRESSED BY EASEMENT DOCUMENTATION RECORDED AT THE MASS. LAND COURT. COPIES ARE AVAILABLE UPON REQUEST. 6. ALL SEPTIC SYSTEM CONSTRUCTION MATERIALS AND PROCEDURES SHALL CONFORM TO THE STATE SANITARY CODE, TITLE 5 AND TOWN OF YARMOUTH HEALTH DEPT. APPROVAL FOR THE DESIGN. 7. A REPLACEMENT 1,500 GAL. H-20 RATED SEPTIC TANK IS PROPOSED TO SERVE THE NEW DWELLING, UTILIZING THE EXISTING SYSTEM COMPONETS. 8. INSTALLER SHALL CONTACT ENGINEER AT TIME OF WORK COMPLETION PRIOR TO EARTH COVERING FOR SYSTEM CERTIFICATION IF REQUIRED. 9. CONTACT THE ENGINEER IF ANY QUESTIONS OR DOUBTS ARISE REGARDING CONDITIONS ENCOUNTERED DURING CONSTRUCTION. 10. NO KNOWN POTABLE WELLS EXIST WITHIN 150 FT. OF THE PROPOSED SEPTIC TANK OR EXISTING COMPONENTS OTHER THAN THOSE SHOWN. 11. SITE WORK SHALL INVOLVE ONLY NATURAL MATERIALS FOR SUBGRADE AND SUBBASE FOR WALKS AND THE DRIVEWAY. RECYCLED MATERIALS SUCH AS "T" BASE AND / OR "ABC' PRODUCTS ARE NOT PERMITTED. 12. REFER TO ARCHITECTS CONSTRUCTION DRAWINGS FOR EXACT BUILDING DIMENSIONS AND THE LANDSCAPE PLAN PREAPRED BY MARY LEBLANC LANDSCAPE DESIGN SHEET L-1. DESIGN DATA HYD. LOADING PROPOSED DWELLING - 2 BEDROOMS X 110 GPD/BR = 220.0 GPD SEPTIC TANK DESIGN 220 GPD X 200% = 440.0 GPD A 1,500 GAL. SEPTIC TANK - ST 1500 -4i-20 IS PROPOSED TO REPLACE j THE EXISTING TANK EXISTING SAS DESIGN - 5 BEDROOM 1978 CODE APPROVED SYSTEM CAPACITY PER EXISTING MUNICIPAL RECORDS *THE DESIGN IS NOT SUITABLE FOR USE WITH A GARBAGE DISPOSAL UNIT REVISED - FEB. 26, 2020 REVISED - DEC. 27, 2019 - WELL SETBACK VARIANCE I REVISED OCTOBER 3, 2019 - CHANGE PATIO TO DECK W/ LAYOUT EXPANSION REVISED NOV. 15, 2018 - MATCH LANDSCAPE PLAN DRIVEWAY REVISED OCTOBER 8, 2018 - STRIKE PERGOLA AND RELATED PATIO TOPOGRAPHIC SITE PLAN SHOWING PROPOSED REPLACEMENT DWELLING AT 6 SMTHS POINT ROAD, WEST YARMOUTH, MA n ASSESSORS' MAP 5, PARCEL 6 f SEPTEMBER 19, 2018 SCALE - AS NOTED I ZH OF MAS, Sa �ROBERT M cN� PREPARED BY o PERRY CIVIL CAPE COD ENGINEERING, INC. 0 fej.o No. 35880® �¢ ROBERT M. PERRY, P.E. ¢QI&TEa`'ea�` P.O. BOX 1517 S/ AL hyo EAST DENNIS, MA 02641 TEL: 508-385-1445 ''. ALBRIGHT.DWG i