Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lot 72- Zone of Contribution: In Out x Acreage q/ 3t . Commercial: Residential: ✓ Street: to I "a S-7- Village: TVillage: aOas7-}{. Floor Plan: ✓- #Bedrooms: 3 Owner: `1 7"2_ P 01-'74.1 c A Installer: 0-4, A- Address: Phone: Phone: Builder: Engineer: 6,1-4 . !. -A.-ca. Address: Phone: Phone: N/A YES NO 1. Required#of copies received �/ 2. Date of soils exam and percolation test not older than 2 years / 3.4-5 ft of naturally occurring pervious material,above water table / 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ✓ 5.Water line 10 ft from septic components Var.: 6c-C-Eri Nt, / 6.Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation,deck Var.: V 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: S 1 FvC,,t- 6.....- 9. 9.Leaching minimum 100 ft from wetlands Var.: ,e/ 10.Leachin ' 'mum 150 ft from drinking well/25 ft irrigation well Var.: V 11.T leachin . urn 10 ft from property line Var.: Z° MS T6+ It.. 12. System s all other setback requirements Var.: V 13.Uses adjustment for maximum high groundwater Var.: V 14. Leachin. s-t 4-5 ft above adj.water or bottom of test hole Var.: 15. Syst.iiii . op or subsoil(A,B horizons)or 5'removal I .. 16.Propos-a contours are suitable V 17. System meets slope requirements-min. 1/8", %"preferred V 18. System meets breakout requirements PVC liner: Wall: ✓ 19. Specified tee sizes areproper, gas baffle on outlet tee / 20. Sewage is under 10,000 gpd for parcel V 21.No garbage disposal V. 22. System adequately sized for its intended use ✓ 23.Minimum 6"stone or compacted below tank and dbox V 24.Manhole covers within 6"of grade,pump chamber cover to grade V 25. Inspection port on plastic chambers/leach field ,/ 26.Electrical permit for pump chamber/Separate meter for duplexes ✓ 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size ,./- 28. f28. Septic tank/pump chamber to be factory waterproofed / 29.Vent provided if leaching below 3 feet,under driveway/parking 30.Buoyancy calculations for tank/pump chamber V 31.Engineer to inspect and certify soils: wall: commercial: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature J` 33.H-20 loading is subject to vehicular traffic,groundwater ✓ 34.Title V Application and permit fee,installer signature ✓ 35.Foundation footing min.2 feet above adjusted ground water for new house ii 36.Deed Restriction required max. #bedrooms: max.flow: gpd J / 37. Check area lots for groundwater/Labelte�groundwater in Assessor's Map ✓ Plan reviewed by: cS rl 4017 /22-- 6 03 03