HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. /0D Lot ya Zone of Contribution: In Out V Acreage 7‘;' 2223
Commercial: Residential:
Street: Ca_ e r'S
Village: Floor Plan: #Bedrooms: 3
Owner: I D u / _�j clk t r, Installer: i ; rC
Address: Phone:
Phone: / L
Builder: Engineer: ) i iv 4 ..r (4J C7 r1k
Address: Phone:
Phone:
, N/A YES NO
1. Required#of copies received
2.Date of soils exam and percolation test not older than 2 years V-
3.
3.4-5 ft of naturally occurring pervious material,above water table t.
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ✓
5.Water line 10 ft from septic components Var.:
6.Benchmark indicated and shown-NGVD if near wetlands V
7. Septic tank minimum 10 ft from foundation, deck Var.:
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: kr-
9. Leaching minimum 100 ft from wetlands Var.: 7 ✓
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 1/
11.Tank/leaching minimum 10 ft from property line Var.:
12. System meets all other setback requirements Var.:
13.Uses adjustment for maximum high groundwater Var.: ✓
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.` k
15. System not in top or subsoil(A,B horizons)or 5' removal
16.Proposed contours are suitable ✓'
17. System meets slope requirements-min. 1/8", %"preferred i..-------�
18. System meets breakout requirements PVC liner: Wall: \ -
19. Specified tee sizes are proper, gas baffle on outlet tee �
20. Sewage is under 10,000 gpd for parcel _- ‘
.Y '
21.No garbage disposal
22. System adequately sized for its intended use
23.Minimum 6"stone or compacted below tank and dbox 1 *
24. Manhole covers within 6"of grade,pump chamber cover to grade
25. Inspection port on plastic chambers/leach field ✓:._
26. Electrical permit for pump chamber/Separate meter for duplexes
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size ,
28. Septic tank/pump chamber to be factory waterproofed V
29. Vent provided if leaching below 3 feet,under driveway/parking
30.Buoyancy calculations for tank/pump chamber
31. Engineer to inspect and certify soils: wall: commercial: \�
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature j
33.H-20 loading is subject to vehicular traffic, groundwater ‘ -:
34.Title V Application and permit fee,installer signature ` ~
/
35.Foundation footing min. 2 feet above adjusted ground water for new house 1/
36.Deed Restriction required max. #bedrooms: max. flow: gpd L7/
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by. 4L?.t�i b os o3
-I`�8-� 2