Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M.83/L Lot Zone of Contribution: In X Out Acreage Commercial: Residential: x Street: 20 LUE-lL F L - t fst-✓E Village: u..) -- ..7 Floor Plan: #Bedrooms: &1----- Owner77-tkm-& le- L(....1{ Installer: "-RD%�`t cn-'-&- Address: Phone: Se.,2 4-t-t P , 1/ Phone: Builder: Engineer:"3:),z4--41/4 Lt .4 L C V t C Z Address: Phone: 'S-1,S 34 '1 G s 0 Phone: N/A YES NO 1. Required#of copies received / 2. Date of soils exam and percolation test not older than 2 years tv 3. 4-5 ft of naturally occurring pervious material, above water table V. 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ✓ 5. Water line 10 ft from septic components Var.: 6. Benchmark indicated and shown-NGVD if near wetlands V 7. Septic tank minimum 10 ft from foundation, deck Var.: / 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9. Leaching minimum 100 ft from wetlands Var.: V 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ✓ 11.Tank/leaching minimum 10 ft from property line Var.: ✓ 12. System meets all other setback requirements Var.: / --- 13. Uses adjustment for maximum high groundwater Var.: ✓ 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: ✓ 15. System not in top or subsoil (A,B horizons) or 5' removal V 16. Proposed contours are suitable ,/ 17. System meets slope requirements-min. 1/8", '/"preferred ✓ 18. System meets breakout requirements PVC liner: Wall: ✓. 19. Specified tee sizes are proper, gas baffle on outlet tee ;/� 4&---- 20. Sewage is under 10,000 gpd for parcel V 21.No garbage disposal ✓ 22. System adequately sized for its intended use ✓. 23. Minimum 6"stone or compacted below tank and dbox I 24. Manhole covers within 6"of grade,pump chamber cover to grade J ‘-. 25. Inspection port on plastic chambers/leach field V 26. Electrical permit for pump chamber/Separate meter for duplexes ✓ 27. Pump system-2"line,weep hole,check valve,tee in dbox,pump size 7- 28. 28. Septic tank/pump chamber to be factory waterproofed ✓ 29. Vent provided if leaching below 3 feet,under driveway/parking V 30. Buoyancy calculations for tank/pump chamber V 31. Engineer to inspect and certify soils: wall: commercial: ✓ 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature V 33.H-20 loading is subject to vehicular traffic, groundwater I 4-- 34. Title V Application and permit fee, installer signature ✓ 35. Foundation footing min. 2 feet above adjusted ground water for new house ✓ 36. Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/Label groundwater in Assessor's Map V Plan reviewed by: l�f�f- 7 i I7 T�/S 6/03/03