Loading...
HomeMy WebLinkAboutEngineer PlansY rmc"Zh.septa9e Plent 4a; . �` , ®.. '' LEGEND ® I �N✓ woon6o { Wohea -- 67 EXISTING CONTOUR --' rfw x 100.98 EXISTING SPOT GRADE �R �tlll-.--0e khk fte pa OVERHEAD WIRES ANeWkere -W- EXISTING WATER SERVICE Phew 2 R..OP9 gcapeP' '� h - G --- EXISTING GAS SERVICE MiJcape Cofli CaPC GreMte Connaq�an i TEST PIT-IzescGry ReaYo anon' `°""'"°" 'r Pi C011eQUC110f1 FX�}BtYCP6M6 •° - BENCHMARK 115 Wa T84n OtJ To nHousa /M �Haufie R0, South 5 � OLD TOWNHOUSE ROAD s p 94.32 EDGE OF PA YEMEN 1 CDN 9480 95.04 95.25 95.44 + 94.bo SIDEWALK PK SET9519 SIDEWALKPK sr 9sd7 SIDEWALK Al` ��� LOCUS MAP --------"__ _... __e_-___ - A --------- N_ 5 2Q --s-_T� 95,35 ` E__ _ � _ - :! /--'_ -___- 95.69 9564 - &A 99.04 Ya oat6Health Depairiment ENERAL NOTES: _.1-14 :{i1� '-�- C9 x 99.53 ;APPROVED i :10153 98,50 1 85x "'x �o.as 6 a 1z LL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL r 0ARD OF HEALTH AND THE DESIGN ENGINEER. i ;ftr M LOT 6 �^ 9715 SOS x 99.36 Na �"' Date 2. LL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS ' rr F THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE n �� 20,4477 S. F. 9e s3`', LOCAL RULES AND REGULATIONS. m x 10523 y m �1�k m 100,ee 'PAVED sP1KE . 9 9660 100.00 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE 101,65 °\ DRIVEWAY a DESIGN ENGINEER. c1 M O 1 x oo ba m 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING y t°tz1 \ 9946 DRIVEWAY & UTILITY FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN /�� ' EASEMENT ENGINEER BEFORE CONSTRUCTION CONTINUES.: Z �,,r 103.16 +t0zmx SPIKE -"^---_rod_` 1`,i 3] `- � too z9 100'1 >6. 5. ELEVATIONS ARE BASED ON AN ASSUMED DATUM. THE DESIGN. ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF 102.4 x 702.63 • THE CONTRACTOR OR OWNER TO NOTIFY THE. LOCAL BOARD OF LU HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. d- o `wf 1E'�/'S _ (,'" ?10iRE 1o1e3 PAl%ED . o t 9�p 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. THERE ARE NO ABUTTING WELLS WITHIN 100' OF THE PROPOSED S.A.S.. o n /HOUSE 115) 169 "rn N DRIVEWAY a N 17 2022 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS '- 10 7 T. O: F.=103.3 (VARIES) GARAGE • V O�1N rn AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE 0 m2 CELLAR FLOOR L.=100.21 , '. DIRECTED BY THE. APPROVING AUTHORITIES. •,,� ��� m t o0s• m HEALTH DEPT' 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY r BH ® DECK �eouE 1�z 10ns• zF THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING `Y 10240x 102 '^ SHED CONSTRUCTION. tO 101.96 11, WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS 10z.4o 0 O P no PL :' IN THE AREA BENEATH AND FOR. 5' ON ALL SIDES OF THE S.A.S. AND Q' 10ae4 --� 102,4 / :10009. REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). , ,raV _ 102,zs - r..j'7 .04 12. AREAS REQUIRING STRIPOUT -0F UNSUITABLE MATERIALS SHALL BE ,,' O °,I i 00 10 x _•-- �1 ,�� ��-� C� SH INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. 13. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED EXISTING .. $�, + 101.64 10 55 t� OF Mgfs SEPTIC SYSTEM COMPONENTS NOT. SHOWN ON THE PLAN. ROPOSED S.A.S. o+ 164.25' P yCy 14. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND 2-500 GALLON CHAMBERS �m o PETER T. r'✓� IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY, SURROUNDED W/4' STONE Stockade fence S 89'53'20" W McENTEE 15. HOUSE LOCATION IS TAKEN FROM FOUNDATION PLOT PLAN BY DOWN '�' CIVIL CAPE ENGINEERING, INC., YARMOUTH PORT, MA DATED 1220/2004, EXISTING LEACH PIT No. 35109 EXISTING .SEPTIC TANKBENCHMARK CONTRACTOR SHALL PUMP, � Q MAP ID: G77-197 'TOP OF TANK, EL.=100.00 ORNER BULKHEAD FILL WITH SAND & ABANDON. GI S1 INV.(OUT)=98.65± L.=102,76 LES` PROPOSED SEPTIC SYSTEM UPGRADE PLAN ,543'o -LC- 115 OLD TOWNHOUSE ROAD, SOUTH YARLOUTH, MA Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 02673 OWNER OF RECORD Engineering by: SCALEDRAWN JOB. NO. DESMARAIS, RICHARD E TRS1"=30' P.T.M. 206-22 Engineering Works, Inc. DESMARAIS, PATRICIA A TRS 115 OLD TOWNHOUSE ROAD 12 West Crossfield Road, Forestdole, MA 02644 DATE CHECKED SHEET NO. SOUTH YARMOUTH, MA 02664 (508) 477-5313 5/31/22 P.T.M. 1 Of. 2 EXISTING SEPTIC TANKPRI PROVIDE RISERS WITH COVERS OVER INLET & INS OUTLET MANHOLES SET TO 6" OG FINISH GRADE. SET T.O.F=103.3±(VARIES) F.G. EL=102.5± r- F.G. EL=102.4± L = 29' ® S=1% (MIN.) 4"SCH40 PVC , EXISTING 48" uQUID .LEVEL ADD GAS BAFFLE INV.=97.7 _. ,.. I INV.=98.65± TOP BRI NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS, PRIOR TO INSTALLATION. 2) SEPTIC TANK & D -BOX SHALL BESET LEVEL AND 4' OF TRUE TO GRADE ON A MECHANICALLY COMPACTED PI STABLE BASE OR OR. SIX IN AGGREGATE. BASE, AS 51 SPECIFIED IN 310 CMR 15.221(2): 3) INSTALL INLET & OUTLET TEES AS REQUIRED. BOTTOM 4) A GAS BAFFLE SHALL BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. DESIGN CRITERIA NUMBER OF BEDROOMS: BEDROOMS SOIL TEXTURAL CLASS: CLAD(LOADING RATE=0.74.GPD/SF) DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 330 GPD DESIGN FLOW: 330 GPD GARBAGE GRINDER: NO -not allowed with design LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF .74 GPD/SF EXISTING SEPTIC TANK: 1000 GALLON CAPACITY PROPOSED D -BOX: 1 INLET, 1 OUTLET (MINIMUM), H-20 RAT USE 2-500 GALLON LEACHING CHAMBERS IN SERIES SIDEWALL AREA: 2(12.8' + 250) X 2 = 151.2 S.F. BOTTOM AREA: 12.8' x 25.0' = 320.0 S.F. TOTAL AREA:.......... .......... .......:471.2 S.F. DESIGN FLOW PROVIDED: 0.74 GPD/SF(471.2 SF) =348.7 G & COVERRISER OF 115 TOWNHOUSE ROAD, SOUTH YARLOUTH, MA SAND 2.5Y 6/4 2.5 .OLD off\ ■ PVC SCALE N.T.S. DRAWN P.T.M. I JOB. NO. 206-22 NOTE:, TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL. 98.0 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. PROPOSED 5.6.5. INSTALL RISER & COVER SET TO 3" OF F.G. TO r F.G. EL.=101.7± (�{ MAINTAIN EFFECTIVE WIDTH = 12.8' OUTLETS INV.= 97.50 H-20 ^ — ^AN , nu , rA/ Ulkl!` run ELEV.= 98.6± ELEV.= 98.00 ELEV.= 97.50 OM ELEV.= 95.50- JRALLY OCCURRING DUS MATERIAL 4.) ABOVE G.W. TEST PIT, EL.=90.0 SYSTEM PROFILE H-20 RATED ONE CHAMBER AND i,S INSPECTION PORT LEACHING SYSTEM SECTION SOIL LOG S.A.S. --2" LAYER OF 1/8" TO 1/2" DOUBLE WASHED STONE (OR APPROVED FILTER FABRIC) —3/4" TO 1-1/2" DOUBLE WASHED STONE DATE: MAY 25, 2022 SOIL EVALUATOR: PETER McENTEE SE#1542 WITNESS:. JAY GARDINER HEALTH AGENT ELEV, TP DEPTH 101.5 LOAMY SAND 100.7 10YR 4/2 91, B LOAMY SAND 10YR 5/8 1 32" PROPOSED S.A.S. 2-500 GALLON CHAMBERS SURROUNDED W/4' STONE SEPTIC LAYOUT t=1 1= =Mwl 1=f 1-wf =I til =Wl1-111=1111 f111�1 ' S 1 -WI SI 1�1 =11=11111_ff MI1—f 111= 1_1I =1 f=1 1=1tf 500 GALLON CAPACITY, H-20 LOADING CHAMBERS N.T.S. 58" PROPOSED SEPTIC 4" KNOCKOUT 20" DIA. COVER 4" KNOCKOUT 04"KNOCKOUT 4" KNOCKOUT 115 TOWNHOUSE ROAD, 500 GALLON CAPACITY, H-20 LOADING CHAMBERS N.T.S. 58" PROPOSED SEPTIC SYSTEM UPGRADE PLAN 115 TOWNHOUSE ROAD, SOUTH YARLOUTH, MA SAND 2.5Y 6/4 2.5 .OLD Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 0267 Engineering by: Engineering Works, Inc. SCALE N.T.S. DRAWN P.T.M. I JOB. NO. 206-22 -- 900 ---- 0 GROUNDWATER ENCOUNTERED PERC RATE: < 2 MIN./INCH 12 West Crossfield .Road, Forestdale, MA 02644 DATE 5/31/22 CHECKED P.T:M. SHEET NO. 2 Of 2 (508) 477-5313