Loading...
HomeMy WebLinkAboutPlans_McDonald,Georgia_REVCCOVER SHEET SCOPE OF WORK GENERAL NOTES REV NAME DATE COMMENTS B J. MENDOZA 6/10/2022 MODULE CHANGE C J. MENDOZA 6/28/22 LAYOUT CHANGE A AC AFCI AZIM COMP DC (E) ESS EXT INT MAG MSP (N) NTS OC PRE-FAB PSF PV RSD TL TYP V W AMPERE ALTERNATING CURRENT ARC FAULT CIRCUIT INTERRUPTER AZIMUTH COMPOSITION DIRECT CURRENT EXISTING ENERGY STORAGE SYSTEM EXTERIOR INTERIOR MAGNETIC MAIN SERVICE PANEL NEW NOT TO SCALE ON CENTER PRE-FABRICATED POUNDS PER SQUARE FOOT PHOTOVOLTAIC RAPID SHUTDOWN DEVICE TRANSFORMERLESS TYPICAL VOLTS WATTS PAGE REV: C 6/28/2022 695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331 PHONE 0 FAX 0 GEORGIA MCDONALD 16 MAYFLOWER LN, YARMOUTH, MA, 02664 PROJECT NUMBER: 223R-016MCDO SHEET DESIGNER: ALLYANNA DIAM CUSTOMER RESIDENCE: TEL. (508) 863-0206 APN: YARM-000060-000068 #180120 (415) 580-6920 ex3 TABLE OF CONTENTS PAGE #DESCRIPTION PV-1.0 COVER SHEET PV-2.0 SITE PLAN PV-3.0 LAYOUT PV-4.0 ELECTRICAL PV-5.0 SIGNAGE PV-1.0 LEGEND AND ABBREVIATIONS SCALE: NTS MAIN PANEL INVERTER(S) AC DISCONNECT(S) DC DISCONNECT(S) PV LOAD CENTER SUB-PANEL CB ATTIC VENT FLUSH ATTIC VENT PVC PIPE VENT SATELLITE DISH T-VENT CHIMNEY FIRE SETBACKS SUNRUN METER METAL PIPE VENT DEDICATED PV METER SERVICE ENTRANCE IQ COMBINER BOX HARDSCAPE PROPERTY LINEINTERIOR EQUIPMENT SHOWN AS DASHED PL SOLAR MODULES SNR MOUNT & SKIRT SNR MOUNT MP SP SM PM INV AC DC LC SE VICINITY MAP • SYSTEM SIZE: 5100W DC, 3840W AC • MODULES: (15) JA SOLAR: JAM60S10-340/MR • INVERTERS: (1) DELTA ELECTRONICS: M4-TL-US • RACKING: ULTRA RAIL SPEEDSEAL FOOT, SEE DRAWING SNR-DC-00438 • SERVICE ENTRANCE CONDUCTORS TO BE REPLACED. • ALL WORK SHALL COMPLY WITH MA 9th Ed. CMR 780 (2015 IRC/IBC/IEBC), MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II MODULES, ARE CLASS A FIRE RATED. • RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • 10.46 AMPS MODULE SHORT CIRCUIT CURRENT. • 16.34 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a) & 690.8 (b)]. • PV INSTALLATION COMPLIES WITH THE NEC 2017 ARTICLE 690.12(B)(2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION #SSTAMPCS #ESTAMPCS • RAPID SHUTDOWN: (15) APSMART RSD-S-PLC ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE • SERVICE ENTRANCE CONDUCTORS TO BE REPLACED. C PL PL PLPLPLPLPLPL PL PL PLPLPLPLPAGE REV: C 6/28/2022 695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331 PHONE 0 FAX 0 GEORGIA MCDONALD 16 MAYFLOWER LN, YARMOUTH, MA, 02664 PROJECT NUMBER: 223R-016MCDO SHEET DESIGNER: ALLYANNA DIAM CUSTOMER RESIDENCE: TEL. (508) 863-0206 APN: YARM-000060-000068 #180120 (415) 580-6920 ex3 SITE PLAN ARRAY PITCH PV AREA (SQFT) AR-01 31°271.6 TRUE AZIM MAG AZIM 258°244° PV-2.0 #SSTAMPSP #ESTAMPSP SITE PLAN - SCALE = 1/16" = 1'-0" MP SEPMINVAC NOTE: ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE INSTALLED ON EACH MODULE PER NEC690.12 (E) RESIDENCE(N) ARRAY AR-01 (E) FENCEMAYFLOWER LN (E) GATE (E) SKYLIGHT (E) DETACHED STRUCTURE (E) FENCE C PAGE REV: C 6/28/2022 695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331 PHONE 0 FAX 0 GEORGIA MCDONALD 16 MAYFLOWER LN, YARMOUTH, MA, 02664 PROJECT NUMBER: 223R-016MCDO SHEET DESIGNER: ALLYANNA DIAM CUSTOMER RESIDENCE: TEL. (508) 863-0206 APN: YARM-000060-000068 #180120 (415) 580-6920 ex3 PV-3.0 LAYOUT #SSTAMP ROOF INFO FRAMING INFO ATTACHMENT INFORMATION Name Type Height Type Max Span OC Spacing Detail Max Landscape OC Spacing Max Landscape Overhang Max Portrait OC Spacing Max Portrait Overhang Configuration AR-01 COMP SHINGLE - UR 1-Story 2X10 RAFTERS 9' - 6"24"ULTRA RAIL SPEEDSEAL FOOT, SEE DRAWING SNR-DC-00438 6' - 0"2' - 4"6' - 0"2' - 0"STAGGERED DESIGN CRITERIA MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 30 PSF WIND SPEED: 140 MPH 3-SEC GUST. S.S.LAG SCREWS: 5/16": 2.5" MIN EMBEDMENT S.S. LAG SCREWS: 5/16": 2.5" MIN EMBEDMENT STRUCTURAL NOTES: ·INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. ·IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12" BOUNDARY REGION OF ANY ROOF PLANE EDGES (EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS FOLLOWS: ··ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50% ··ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS D1 - AR-01 - SCALE: 1/4" = 1'-0" AZIM:244° PITCH: 31° 9'-11"13'-3" 26'-7" 11'-2" 2'-6" 1'-5" 6" 2'-9" 4' TYP C M 240V METER SOCKET 100A CONTINUOUS (N) MA SMART UTILITY REVENUE METER UTILITY SIDE OF CIRCUIT CONNECTS TO TOP LUGS - (LINE AT TOP LOAD AT BOTTOM) (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU221RB 3R, 30A,2P 120/240VAC 3 12 JUNCTION BOX OR EQUIVALENT PV MODULES JA SOLAR: JAM60S10-340/MR (15) MODULES (1) STRING OF (7) MODULES (1) STRING OF (8) MODULES (15) APSMART RSD-S-PLC MODULE LEVEL RAPID SHUTDOWN DEVICES DELTA ELECTRONICS: M4-TL-US 3840 WATT INVERTER LOAD RATED DC DISCONNECT WITH AFCI, APSMART TRANSMITTER NOTE: TOTAL PV BACKFEED = 20A USED FOR INTERCONNECTION CALCULATIONS 3 3 (N) 20A PV BREAKER AT OPPOSITE END OF BUSBAR FACILITY GROUND FACILITY LOADS EXISTING 100A MAIN BREAKER EXISTING 125A MAIN PANEL M METER #: EVERSOURCE 2290893 120/240 VAC SINGLE PHASE SERVICE UTILITY GRID NEW 100A BREAKER NEW 100A METER MAIN CONDUIT SCHEDULE #CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4) 10 AWG PV WIRE NONE (1) 10 AWG BARE COPPER 2 3/4" EMT OR EQUIV.(4) 10 AWG THHN/THWN-2 NONE (1) 10 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV.(2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 PAGE REV: C 6/28/2022 695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331 PHONE 0 FAX 0 GEORGIA MCDONALD 16 MAYFLOWER LN, YARMOUTH, MA, 02664 PROJECT NUMBER: 223R-016MCDO SHEET DESIGNER: ALLYANNA DIAM CUSTOMER RESIDENCE: TEL. (508) 863-0206 APN: YARM-000060-000068 #180120 (415) 580-6920 ex3 PV-4.0 ELECTRICAL #ESTAMP GENERAL NOTES: • 332 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. SYSTEM CHARACTERISTICS - INVERTER 1 SYSTEM SIZE: SYSTEM OPEN CIRCUIT VOLTAGE: SYSTEM OPERATING VOLTAGE: MAX ALLOWABLE DC VOLTAGE: SYSTEM OPERATING CURRENT: SYSTEM SHORT CIRCUIT CURRENT: 5100 W 372 V 278 V 600 V 19.58 A 26.15 A MODULE CHARACTERISTICS JA SOLAR: JAM60S10-340/MR: OPEN CIRCUIT VOLTAGE: MAX POWER VOLTAGE: SHORT CIRCUIT CURRENT: 340 W 41.55 V 34.73 V 10.46 A C PAGE REV: C 6/28/2022 695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331 PHONE 0 FAX 0 GEORGIA MCDONALD 16 MAYFLOWER LN, YARMOUTH, MA, 02664 PROJECT NUMBER: 223R-016MCDO SHEET DESIGNER: ALLYANNA DIAM CUSTOMER RESIDENCE: TEL. (508) 863-0206 APN: YARM-000060-000068 #180120 (415) 580-6920 ex3 SIGNAGE PV-5.0 #ESTAMP MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 16.00 AMPS 240 VAC LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): NEC 2020: 690.54 PV SYSTEM DISCONNECT WARNING! DO NOT RELOCATE THIS OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER AND ESS OCPD (IF APPLICABLE). PER CODE(S): NEC 2020: 705.12(B)(3)(2) NOTES AND SPECIFICATIONS: ·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. ·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. ·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. ·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. ·DO NOT COVER EXISTING MANUFACTURER LABELS. SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): NEC 2020: 690.56(C) 4" 3" ELECTRICAL SHOCK HAZARD WARNING TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020: 690.13(B) !INVERTER 1 PHOTOVOLTAIC DC DISCONNECT MAXIMUM SYSTEM VOLTAGE:VDC600 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): NEC 2020: 690.53 WARNING: PHOTOVOLTAIC POWER SOURCE WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): NEC 2020: 690.31(D)(2), IFC 2012: 605.11.1.4 CAUTION: 16 MAYFLOWER LN, YARMOUTH, MA, 02664 SOLAR PANELS ON ROOF PER CODE(S): NEC 2020 : 705.10, 710.10 MULTIPLE SOURCES OF POWER LABEL LOCATION: INSTALLED WITHIN 3' OF RAPID SHUT DOWN SWITCH PER CODE(S): NEC 2020: 690.56(C)(2), IFC 2012: 605.11.1, IFC 2018: 1204.5.3 RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM WARNING! SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM DUAL POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S): NEC 2020: 705.12(C) ! DO NOT ADD LOADS PHOTOVOLTAIC SYSTEM COMBINER PANEL WARNING LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): NEC 2020: 705.12(D)(2)(3)(c) SERVICE ENTRANCE AC DISCONNECT PV PRODUCTION METER INVERTER (EXT) MAIN PANEL AND AND PV BREAKER DISCONNECT(INT) C