HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST //
Location: A.M. 13 3 Lot t 3 7 Zone of Contribution: In Out_/ Acreage Si b b�
"�?, Commercial: Residential:
Street: a 12 3 Z ) i 5 (c r" Aft)
Village: Floor Plan: #Bedrooms: 3
Owner: Co-`/- e/t..) Ccu rtyve -_ Installer: Dv c
Address: ( Phone:
Phone:
Builder: Engineer: L-2. . C L' n.), 's.i ce,ikj
Address: Phone:
Phone:
N/A YES NO
1. Required#of copies received
2.Date of soils exam and percolation test not older than 2 years
3.4-5 ft of naturally occurring pervious material,above water table 1✓
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ,./.-
5.
,/5.Water line 10 ft from septic components Var.: t/ '
6.Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.:
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 1
9. Leaching minimum 100 ft from wetlands Var.: 1 .
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11.Tank/leaching minimum 10 ft from property line Var.: I/ /
12. System meets all other setback requirements Var.:
13. Uses adjustment for maximum high groundwater Var.: (./
14.Leaching set 4-5 ft above adj. water or bottom of test hole Var.:
15. System not in top or subsoil(A,B horizons)or 5' removal
16.Proposed contours are suitable
17. System meets slope requirements-min. 1/8", i/"preferred
18. System meets breakout requirements PVC liner: Wall: ` -•_
19. Specified tee sizes are proper, gas baffle on outlet tee LZ---'
20. Sewage is under 10,000 gpd for parcel v--------,-.'21.No garbage disposal l!__ _,../
-
22. System adequately sized for its intended use V
23.Minimum 6"stone or compacted below tank and dbox V
24. Manhole covers within 6"of grade,pump chamber cover to grade
25. Inspection port on plastic chambers/leach field
26. Electrical permit for pump chamber/Separate meter for duplexes r :.,
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size
28. Septic tank/pump chamber to be factory waterproofed
29. Vent provided if leaching below 3 feet,under driveway/parking
30.Buoyancy calculations for tank/pump chamber
31. Engineer to inspect and certify soils: wall: commercial:
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature �/.
33.H-20 loading is subject to vehicular traffic, groundwater
34.Title V Application and permit fee,installer signature z 1/4------"
35.Foundation footing min. 2 feet above adjusted ground water for new house
36.Deed Restriction required max. #bedrooms: max. flow: gpd ,\.....2.-
37.
-
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by. 6 0.3 0