HomeMy WebLinkAboutPlans_Plan_Cutter_Jeffrey_Rev B_StampedCOVER SHEET
SCOPE OF WORK GENERAL NOTES
REV NAME DATE COMMENTS
A
AC
AFCI
AZIM
COMP
DC
(E)
ESS
EXT
INT
MAG
MSP
(N)
NTS
OC
PRE-FAB
PSF
PV
RSD
TL
TYP
V
W
AMPERE
ALTERNATING CURRENT
ARC FAULT CIRCUIT INTERRUPTER
AZIMUTH
COMPOSITION
DIRECT CURRENT
EXISTING
ENERGY STORAGE SYSTEM
EXTERIOR
INTERIOR
MAGNETIC
MAIN SERVICE PANEL
NEW
NOT TO SCALE
ON CENTER
PRE-FABRICATED
POUNDS PER SQUARE FOOT
PHOTOVOLTAIC
RAPID SHUTDOWN DEVICE
TRANSFORMERLESS
TYPICAL
VOLTS
WATTS
PAGE
REV: B 7/7/2022
695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331
PHONE 0
FAX 0
JEFFREY CUTTER
33 PRINCE RD, YARMOUTH, MA,
02601
PROJECT NUMBER:
223R-033CUTT
SHEET
DESIGNER:
MARVIN CHRISTOPHER
FORTALEZA
CUSTOMER RESIDENCE:
TEL. (617) 208-9733
APN: YARM-000029-000091
#180120
(415) 580-6920 ex3
TABLE OF CONTENTS
PAGE #DESCRIPTION
PV-1.0 COVER SHEET
PV-2.0 SITE PLAN
PV-3.0 LAYOUT
PV-4.0 ELECTRICAL
PV-5.0 SIGNAGE
PV-1.0
LEGEND AND ABBREVIATIONS
SCALE: NTS
MAIN PANEL
INVERTER(S)
AC DISCONNECT(S)
DC DISCONNECT(S)
PV LOAD CENTER
SUB-PANEL
CB
ATTIC VENT
FLUSH ATTIC VENT
PVC PIPE VENT
SATELLITE DISH
T-VENT
CHIMNEY
FIRE SETBACKS
SUNRUN METER
METAL PIPE VENT
DEDICATED PV METER
SERVICE ENTRANCE
IQ COMBINER BOX HARDSCAPE
PROPERTY LINEINTERIOR EQUIPMENT
SHOWN AS DASHED
PL
SOLAR MODULES
SNR MOUNT & SKIRT
SNR MOUNT
MP
SP
SM
PM
INV
AC
DC
LC
SE
VICINITY MAP
• SYSTEM SIZE: 11900W DC, 10000W AC
• MODULES: (35) JA SOLAR: JAM60S10-340/MR
• INVERTERS: (1) SOLAREDGE TECHNOLOGIES:
SE10000H-USSN
• RACKING: SNAPNRACK RLU; RL UNIVERSAL, SPEEDSEAL
TRACK ON COMP, SEE DETAIL SNR-DC-00436
• ALL WORK SHALL COMPLY WITH MA 9th Ed. CMR 780 (2015 IRC/IBC/IEBC),
MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION
INSTRUCTIONS.
• PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020.
• ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020.
• PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY
GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35.
• MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.
• INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.
• RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.
• SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II
MODULES, ARE CLASS A FIRE RATED.
• RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL
CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1).
• CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G).
• ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT.
• 10.46 AMPS MODULE SHORT CIRCUIT CURRENT.
• 16.34 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a) & 690.8 (b)].
• PV INSTALLATION COMPLIES WITH THE NEC 2017 ARTICLE 690.12(B)(2).
CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE
LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION
#SSTAMPCS
#ESTAMPCS
PLPLPL
PLPLPAGE
REV: B 7/7/2022
695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331
PHONE 0
FAX 0
JEFFREY CUTTER
33 PRINCE RD, YARMOUTH, MA,
02601
PROJECT NUMBER:
223R-033CUTT
SHEET
DESIGNER:
MARVIN CHRISTOPHER
FORTALEZA
CUSTOMER RESIDENCE:
TEL. (617) 208-9733
APN: YARM-000029-000091
#180120
(415) 580-6920 ex3
SITE PLAN
ARRAY
PITCH
PV AREA
(SQFT)
AR-01 40°108.6
AR-02 40°362.1
AR-03 19°163167°181°
257°
TRUE
AZIM
MAG
AZIM
361°347°
271°
PV-2.0
#SSTAMPSP #ESTAMPSP
SITE PLAN DETAIL - SCALE = 3/32" = 1'-0"SITE PLAN - SCALE = 3/128" = 1'-0"
(E) RESIDENCE
SE
MP
AC
INV
PRINCE R
D
PM
(N) ARRAY AR-02
(N) ARRAY AR-03
(N) ARRAY AR-01B
PAGE
REV: B 7/7/2022
695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331
PHONE 0
FAX 0
JEFFREY CUTTER
33 PRINCE RD, YARMOUTH, MA,
02601
PROJECT NUMBER:
223R-033CUTT
SHEET
DESIGNER:
MARVIN CHRISTOPHER
FORTALEZA
CUSTOMER RESIDENCE:
TEL. (617) 208-9733
APN: YARM-000029-000091
#180120
(415) 580-6920 ex3
PV-3.0
LAYOUT
#SSTAMP
ROOF INFO FRAMING INFO ATTACHMENT INFORMATION
Name Type Height Type Max
Span
OC
Spacing Detail Max Landscape
OC Spacing
Max Landscape
Overhang
Max Portrait
OC Spacing
Max Portrait
Overhang Configuration
AR-01 COMP SHINGLE - RLU 2-Story 1X8 RAFTERS 12' - 7"16"RL UNIVERSAL, SPEEDSEAL TRACK ON
COMP, SEE DETAIL SNR-DC-00436 5' - 4"2' - 1"4' - 0"2' - 0"STAGGERED
AR-02 COMP SHINGLE - RLU 2-Story 1X8 RAFTERS 13' - 1"16"RL UNIVERSAL, SPEEDSEAL TRACK ON COMP, SEE
DETAIL SNR-DC-00436 5' - 4"2' - 1"4' - 0"2' - 0"STAGGERED
AR-03 COMP SHINGLE - RLU 2-Story 1X8 RAFTERS 8' - 2"16"RL UNIVERSAL, SPEEDSEAL TRACK ON COMP, SEE
DETAIL SNR-DC-00436 5' - 4"2' - 1"4' - 0"1' - 10"STAGGERED
DESIGN CRITERIA
MAX DISTRIBUTED LOAD: 3 PSF
SNOW LOAD: 30 PSF
WIND SPEED:
140 MPH 3-SEC GUST.
S.S.LAG SCREWS:
5/16": 2.5" MIN EMBEDMENT
STRUCTURAL NOTES:
·INSTALLERS SHALL NOTIFY
ENGINEER OF ANY POTENTIAL
STRUCTURAL ISSUES
OBSERVED PRIOR TO
PROCEEDING W/
INSTALLATION.
·IF ARRAY (EXCLUDING SKIRT)
IS WITHIN 12" BOUNDARY
REGION OF ANY ROOF PLANE
EDGES (EXCEPT VALLEYS),
THEN ATTACHMENTS NEED
TO BE ADDED AND OVERHANG
REDUCED WITHIN THE 12"
BOUNDARY REGION ONLY AS
FOLLOWS:
··ALLOWABLE ATTACHMENT
SPACING INDICATED ON
PLANS TO BE REDUCED BY
50%
··ALLOWABLE OVERHANG
INDICATED ON PLANS TO BE
1/5TH OF ALLOWABLE
ATTACHMENT SPACING
INDICATED ON PLANS
SEE SITE PLAN FOR NORTH ARROW
D1 - AR-01 - SCALE: 1/8" = 1'-0"
AZIM: 347°
PITCH: 40°
D2 - AR-02 - SCALE: 1/8" = 1'-0"
AZIM: 257°
PITCH: 40°
D3 - AR-03 - SCALE: 1/8" = 1'-0"
AZIM: 167°
PITCH: 19°
4' TYP
9'-11"
11'-2"
1'
27'-6"
10'-8"
4'-1"
6"
6"3"
1'
4' TYP
1'-3"
13'-3"
1'-8"
6'-9"6'-7"
26'-7"
16'-9"
3'-3"
5"10"
2'-9"
5'-4" TYP
16'-9"
9'-11"
1'
8'-6"
10'-11"
5'-5"
6"
9'-2"
B
PRREOEFENISGSNIOE N LA
OF M H ATLSASEA
CWHN
UOSMETMTOSCVINCENT
MWUMVANEZA
CIVIL
NO. 54772
STRUCTURAL ONLY
FACILITY
GROUND
FACILITY
LOADS
EXISTING 200A
MAIN BREAKER
EXISTING
200A MAIN
PANEL
SUPPLY SIDE TAP
(N) LOCKABLE
BLADE TYPE
FUSED AC
DISCONNECT
60A FUSES
SQUARE D
D222NRB
3R, 60A
120/240VAC
M
METER #:
EVERSOURCE 2284898
120/240 VAC
SINGLE PHASE
SERVICE
UTILITY
GRID
4
JUNCTION BOX
OR EQUIVALENT 12
SOLAREDGE TECHNOLOGIES:
SE10000H-USSN WITH
REVENUE GRADE METERING
10000 WATT INVERTER
LOAD RATED DC DISCONNECT
WITH AFCI, RAPID SHUTDOWN
COMPLIANT
PV MODULES
JA SOLAR: JAM60S10-340/MR
(35) MODULES
OPTIMIZERS WIRED IN:
(1) SERIES OF (15) OPTIMIZERS
(1) SERIES OF (11) OPTIMIZERS
(1) SERIES OF (9) OPTIMIZERS
SOLAREDGE POWER OPTIMIZERS
P370
M
240V METER SOCKET
100A CONTINUOUS
(N) MA SMART
UTILITY
REVENUE
METER
UTILITY SIDE OF CIRCUIT
CONNECTS TO TOP LUGS -
(LINE AT TOP LOAD AT BOTTOM)
3 3
CONDUIT SCHEDULE
#CONDUIT CONDUCTOR NEUTRAL GROUND
1 NONE (6) 10 AWG PV WIRE NONE (1) 10 AWG BARE COPPER
2 3/4" EMT OR EQUIV.(6) 10 AWG THHN/THWN-2 NONE (1) 10 AWG THHN/THWN-2
3 3/4" EMT OR EQUIV.(2) 6 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2
4 3/4" EMT OR EQUIV.(2) 6 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2
PAGE
REV: B 7/7/2022
695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331
PHONE 0
FAX 0
JEFFREY CUTTER
33 PRINCE RD, YARMOUTH, MA,
02601
PROJECT NUMBER:
223R-033CUTT
SHEET
DESIGNER:
MARVIN CHRISTOPHER
FORTALEZA
CUSTOMER RESIDENCE:
TEL. (617) 208-9733
APN: YARM-000029-000091
#180120
(415) 580-6920 ex3
PV-4.0
ELECTRICAL
#ESTAMP
SYSTEM CHARACTERISTICS - INVERTER 1
SYSTEM SIZE:
SYSTEM OPEN CIRCUIT VOLTAGE:
SYSTEM OPERATING VOLTAGE:
MAX ALLOWABLE DC VOLTAGE:
SYSTEM OPERATING CURRENT:
SYSTEM SHORT CIRCUIT CURRENT:
11900 W
15 V
400 V
480 V
29.75 A
45 A
P370 OPTIMIZER CHARACTERISTICS:
MIN INPUT VOLTAGE: 8 VDC
MAX INPUT VOLTAGE: 60 VDC
MAX INPUT ISC: 11 ADC
MAX OUTPUT CURRENT: 15 ADC
MODULE CHARACTERISTICS
JA SOLAR: JAM60S10-340/MR:
OPEN CIRCUIT VOLTAGE:
MAX POWER VOLTAGE:
SHORT CIRCUIT CURRENT:
340 W
41.55 V
34.73 V
10.46 A
PAGE
REV: B 7/7/2022
695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331
PHONE 0
FAX 0
JEFFREY CUTTER
33 PRINCE RD, YARMOUTH, MA,
02601
PROJECT NUMBER:
223R-033CUTT
SHEET
DESIGNER:
MARVIN CHRISTOPHER
FORTALEZA
CUSTOMER RESIDENCE:
TEL. (617) 208-9733
APN: YARM-000029-000091
#180120
(415) 580-6920 ex3
SIGNAGE
PV-5.0
#ESTAMP
MAXIMUM AC OPERATING CURRENT:
NOMINAL OPERATING AC VOLTAGE:
41.67 AMPS
240 VAC
LABEL LOCATION:
AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF
INTERCONNECTION.
PER CODE(S): NEC 2020: 690.54
PV SYSTEM DISCONNECT
WARNING!
DO NOT RELOCATE THIS
OVERCURRENT DEVICE
POWER SOURCE OUTPUT CONNECTION
LABEL LOCATION:
ADJACENT TO PV BREAKER AND ESS
OCPD (IF APPLICABLE).
PER CODE(S): NEC 2020:
705.12(B)(3)(2)
NOTES AND SPECIFICATIONS:
·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE
110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR
IF REQUESTED BY THE LOCAL AHJ.
·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
WORDS, COLORS AND SYMBOLS.
·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING
METHOD AND SHALL NOT BE HAND WRITTEN.
·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT
INVOLVED.
·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY
SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED.
·DO NOT COVER EXISTING MANUFACTURER LABELS.
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
SOLAR ELECTRIC
PV PANELS
TURN RAPID SHUTDOWN
SWITCH TO THE "OFF"
POSITION TO SHUT DOWN
PV SYSTEM AND REDUCE
SHOCK HAZARD IN THE
ARRAY.
LABEL LOCATION:
ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE
DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
ARE CONNECTED.
PER CODE(S): NEC 2020: 690.56(C)
4"
3"
ELECTRICAL SHOCK HAZARD
WARNING
TERMINALS ON LINE AND LOAD
SIDES MAY BE ENERGIZED IN
THE OPEN POSITION
LABEL LOCATION:
INVERTER(S), AC/DC DISCONNECT(S),
AC COMBINER PANEL (IF APPLICABLE).
PER CODE(S): NEC 2020: 690.13(B)
!INVERTER 1
PHOTOVOLTAIC DC DISCONNECT
MAXIMUM SYSTEM VOLTAGE:VDC480
LABEL LOCATION:
INVERTER(S), DC DISCONNECT(S).
PER CODE(S): NEC 2020: 690.53
WARNING: PHOTOVOLTAIC
POWER SOURCE
WARNING: PHOTOVOLTAIC
POWER SOURCE
LABEL LOCATION:
INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,
AT EACH TURN, ABOVE AND BELOW PENETRATIONS,
ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS.
PER CODE(S): NEC 2020: 690.31(D)(2), IFC 2012:
605.11.1.4
LABEL LOCATION:
INSTALLED WITHIN 3' OF RAPID SHUT DOWN
SWITCH PER CODE(S): NEC 2020: 690.56(C)(2), IFC
2012: 605.11.1, IFC 2018: 1204.5.3
RAPID SHUTDOWN SWITCH
FOR SOLAR PV SYSTEM
WARNING!
SOURCES: UTILITY GRID
AND PV SOLAR ELECTRIC
SYSTEM
DUAL POWER SUPPLY
LABEL LOCATION:
UTILITY SERVICE METER AND MAIN
SERVICE PANEL.
PER CODE(S): NEC 2020: 705.12(C)
!
DO NOT ADD LOADS
PHOTOVOLTAIC SYSTEM
COMBINER PANEL
WARNING
LABEL LOCATION:
PHOTOVOLTAIC AC COMBINER (IF
APPLICABLE).
PER CODE(S): NEC 2020: 705.12(D)(2)(3)(c)