HomeMy WebLinkAboutReview Chceklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST x
Location: A.M. Lot Zone of Contribution: In Out' Acreage
Street: �Q FJ�te Commercial: Residential:
Village: Floor Plan: yrs # Bedrooms:
Owner: Installer: C"--r- P' 1
Address: Phone: J
Phone:
Builder: EngineerEngineer
Address: Phone:
Phone:
r
1. Required# of cop ies received N/A YES I NO
2. Date of soils exam and percolation test not older than 2 years I I
3. 4-5 ft of naturally occurring pervious material, above water table
4. Foundation 2 ft above high point of roadHP.: Fnd: Var.: /
5. Water line 10 ft from septic components Var.:
6. Benchmark indicated and shown- NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.: 6fr fI
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9. Leaching minimum 100 ft from wetlands
Var.:
10. Leaching minimum 150 ft from drinking welU25 ft irrigation well Var.: i
11. Tank/leaching minimum 10 ft from property line Var.:
12. System meets all other setback requirements Var.: f '{
i 1
13. Uses adjustment for maximum high groundwater Var.: � /
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.:
15. System not in top or subsoil(A,B horizons) or 5' removal '
16. Proposed contours are suitable r
✓/ I
17. System meets slope requirements- min. 1/8", '/s"preferred I ✓
18. System meets breakout requirements PVC liner: Wall: 1/
19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel
21. No garbage disposal
✓22. System adequately sized for its intended use
23. Minimum 6"stone or compacted below tank and dbox /
j
, I
24. Manhole covers within 6" of grade, pump chamber cover to grade i
25. Inspection port on plastic chambers/leach field i ✓ I
26. Electrical permit for pump chamber/Separate meter for duplexes
27. Pump system-2" line,weep hole check valve, tee in dbox, pump size 7
28. Septic tank/pump chamber to be factory waterproofed / I i
29. Vent provided if leaching below 3 feet, under driveway/parking t .j
30. Buoyancy calculations for tank/pump chamber ✓
31. Engineer to inspect and certify soils: wall: commercial: ✓f
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature {
33. H-20 loading is subject to vehicular traffic, groundwater 67
34. Title V Application and permit fee, installer signature /
35. Foundation footin min. 2 feet above adjusted ground water for new house / V
36. Deed Restriction required max. #bedrooms: max. flow
1 37. Check area lots for groundwater/Label groundwater in Assessor's Map gpd v
Plan reviewed by: I/Vi/1//". - ,III1 In,