Loading...
HomeMy WebLinkAboutEngineer PlanSY PROVIDE MIN. 2W DIAM. WATERTIGHT ACCESS COVERS TO WITHIN r OF FIN. GRADE NOTE: 2 1 PRECAST H-10 THICKNESS RISERS 2'0 40.05' - r MIN. SUMP •• • • : • .. 1Y MIN. INC..DIM. EXISTING 1000 GAL 10" SEPTIC TANK** °o T74" TEE 38.72'±* o°o°a° GAS°+ �;.14' LIQ. LEVEL ACME OR EQUAL).. 38.27' 8" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 (21) (1.8 % SLOPE) FOUNDATION EXIST. — SEPTIC TANK 25' D' BOX *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEV TI PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM _99— EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. PROPOSED CONTOUR 198,41 PROPOSED SPOT EL THI 0 TEST HOLE SLOPE OF GROUND rQ� UTILITY POLE FIRE HYDRANT NOTE: NOT ALL Sr1O= MAY APPM W DRAYRNB TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: JASON GARDINER DATE: 6/21/2022 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS QP ELEV. a 41,0' FILL A LS 27" 1OYR 3/4 8.75' B LS 36" 1 OYR 5/6 38.0' C PERC MS 1OYR 7/6 132" L J 30_0' NO GROUNDWATER ENCOUNTERED DICE #22-960 (NOT To wAj3 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE 140 PVC LEVEL IST 2' ALL, SYSTEM COMPONENTS SHALL BE MIRKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCtETE COVERS TO WITHIN 3" GRADE 296 SLDPE REQUIRED OVER BLOCKS OR pLL PRECAST RISERS COMPONENTS H-20 (TYP.) io°000000eo Ig®88®BBl3dtz3E=1' ClL�9l�JlJIJClG�C7T.�tlC� 000a0000 jo 000000 0 0 0 36.0 "-1-1/2" DOUBLE WASHED STONE 4' MIN. H-20 50) GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. AROUND PRECAST STRUCTURES (2) UNITS REQUIRED ALL DIMENSIONS TO OUTSIDE OF STONE: 25.00' X 12.8$' 30.0' BOTTOM TH-1 1_96 SLOPE) NO GROUNDWATER FOUND ( 12' LEACHING FACILITY **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT 1000 GALLONS AND ITS SUITABIILTY FOR RE -USE. REPLACE WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE > C o a g � w 38 C / m k wO LOT 116 \ 12,100± S.F. I A E RIVE EXISTING 41 DWELLING TOF = 42.6' KL GRA L °ryy DECK cCl a I LP _C�� CAUTION GAS LINE - 0 Scale: 1"= 20' 0 10 20 40 SO FEET m =41.7' NAVD88 0 O F - NOTES 1. DATUM IS NAND 88 2, MUNICIPAL WATER IS QQSTING 3, MINIMUM PIPE PITCH TO BE 1/8" PER FOOL 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -1Q (H-20 LEACHING) 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6, CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT UNE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. Jan Setucket ?� a 0cu o ear Ari: ,mend Road yIt Storey Ni0 R`oo� 10. CONTRACTOR SHALL BE RESPONSIBLE FORCALLING (� G M AND VERIFYING ITHE LOGSAFE CATION OF ALL UNDERGROUND & LOCUS MAP OVERHEAD UTILITIES PRIOR TO COMMENCEMENT Cm SCALE 1"=2000'± WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHAD_ ASSESSORS MAP 134 PARCEL 126 BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. LOCUS IS WITHIN FEMA FLOOD ZONE X 12. EXISTING LEACHING FACILITY SHALL BE PUMPED (AREA OF MINIMAL FLOOD HAZARD) AS AND REMOVED OR PUMPER AND FILLED WITH CLEAN SHOWN ON COMMUNITY PANEL #25001CO579J SAND. DATED 7/16/2014 DATE DANIEL A. OJALA, P.E., P.L.S. SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 3 BEDROOM DWELLING DESIGN FLOW. 3 BEDROOMS 0 110 GPD = 330 GPD USE -A-330 GPD DES6N fLOW SEPTIC TANK: 330 GPD (2) = 660 **RE -USE EXISTING 1000 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) 112 GPD BOTTOM 25 x 12.83 (.74) 237 GPD TOTAL: 472 S.F. 349 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND MA APPROVED DATE OARD F HEALTH ' TITLE 5 SITE PLAN OF #41 BARNACLE ROAD YARMOUTH PORT, MA PREPARED FOR qsc KELLY TURNER .A 1 DATE: JUNE 23, 2022 4 `� N 02 off 5Q8-382-4541 fax 508-362-9880 df' owncape.com down ape tAjiAeeriAd, iuc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARM0U77/P0RT AfA 02675 22-160 TURNER.DWG