Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. / 3'/ Lot /A-4 Zone of Contribution: In Out v Acreage jai/C?(� � ' Commercial: Residential: L� Street: cY1c,,e\. Village: Floor Plan: #Bedrooms: ,3 Owner: k'42 //y 7 'r p e Installer: R0b c-'1-1- tO V 11-- Address: Phone: Phone: Builder: Engineer: 1) c)-C,v1".a r_ A- D Address: Phone: Phone: N/A YES NO -------- 1. Required#of copies received 2. Date of soils exam and percolation test not older than 2 years { 3.4-5 ft of naturally occurring pervious material, above water table V - 4.Foundation 2 ft above high point of road H.P.: End: Var.: IV' _ _ 5. Water line 10 ft from septic components Var.: 6.Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: L.,/� 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: t/ 9. Leaching minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11.Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: 13.Uses adjustment for maximum high groundwater Var.: 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: 15. System not in top or subsoil(A,B horizons)or 5' removal VI,/ t/ 16.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", '/"preferred ' / , 18. System meets breakout requirements PVC liner: Wall: 19. Specified tee sizes are proper, gas baffle on outlet tee l/ 20. Sewage is under 10,000 gpd for parcel i 21.No garbage disposal y V 4-2322. System adequately sized for its intended use L.4-- 23. .Minimum 6"stone or compacted below tank and dbox 24. Manhole covers within 6"of grade, pump chamber cover to grade `� 25. Inspection port on plastic chambers/leach field 26. Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size 28. Septic tank/pump chamber to be factory waterproofed t/ _ 29. Vent provided if leaching below 3 feet,under driveway/parking ✓� 30. Buoyancy calculations for tank/pump chamber 31. Engineer to inspect and certify soils: wall: commercial: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature } t-...--// 33. H-20 loading is subject to vehicular traffic, groundwater '/ 34.Title V Application and permit fee, installer signature 35. Foundation footing min. 2 feet above adjusted ground water for new house .....---/ 36. Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/Label/groundwater in Assessor's Map Plan reviewed by: v` _ ___ 03 0: �- /gra Z