HomeMy WebLinkAboutEngineer Plans\Y12all Map 22
OQ8) �\� Parcel 215.1
' \
< Shed
Ma 22 \ Proposed
Mop fSilt Fence
Parcel 217 (as required)
(9.g) r (10.5
Existing Elev- S
1 3r,
Proposed Contour �O 1z•
(rq s% Lot
\ro �� 81000± Sq. Ft. F
10 °x
n Pie O i ' ?0'--12
10.0 �Nhrouo
Pro ose
d
Gevel os Deck
10\ / 1\1 �\ Proposed\
�\ /°mow Ali .\ w 3 Bedroom
(vo l o TOF EL = 13.3±
R eAserve ?) 2
�gnan re W\ d
(a 1 1 \ aA o._ST 0 60
/ ry
0 \\CP +*++* + +* 12 �x
\.0 , °' * + �� Obs Port
F�
o. N�N
o° SAS
�OyJ0 \ \ \ °'� (ra.6)
cy \ \
NOTE: 0 20 0
LOCATION OF UTILITIES 1S APPROXIMATE AND ALL \
UNDERGROUND AND OVERHEAD UTILITIES MUST BE �g
DETERMINED IN THE FIELD PRIOR TO COMMENCEMENT
OF ANY WORK, THIS INCLUDES, BUT NOT LIMITED TO,
REQUESTS TO DIGSAFE, ANY PRIVATE UTILITY COMPANIES
AND THE LOCAL WATER DEPARTMENT.
Map 22
Parcel 214
#1
fop Iron Pipe
TBM EL = 10.9
(r0>)
See Excavation Notes
Map 22
Parcel 219
GRAPHIC SCALE
10 20 40
( IN FEET )
1 inch = 20 ft.
Map 22
Parcel 213
Zoning
R-25
25,000 SF
150' Frontage
Max. Coverage 25%
Proposed Coverage 17.0%
Setbacks
Front
30'
Side
15'
Rear
20'
\ -off Lewis Bay Roa�
a _
\� �nglewood \
Beach
Lewis Bay
WEST YARMOUTH, MA
fl SITE LOCUS
I( NOT TO SCALE
Owners:
Edwards Family Revocable Trust
Joanne Nolan Edwards, Trustee
Tyrone Edwards, Trusteeu?��
Berwick Road
411 fj?7,?.West Yarmouth, MA 02673 FE33 +0 ra
II HEALTH
1.) Assessor's Map 22 Parcel 218L-
0,-
sS 2.) D812505/0
? S
STEPHEN c5 3.) LC Plan 11435—A Lot 3
f ° B. Gn 4.) This property is not in a Wellhead
M1'"_ h,1aO
�1 Na.10r1;RE Protection District
5.) This property is in Flood Zone AE
1sr�'�vti Base Flood Elevation 11.0
Firm Map 25001CO588J 7/16/14
6.) Elevations shown ore NAVD88
Note:
Floor Plans to be submitted with building permit.
Proposed Site and Septic Plan
10 Berwick Road
Prepared for:
Edwards Family Revocable Trust
6 BerwicK Road
West Yarmouth, MA 02673
West Yarmouth, MA
Prepared by:
All Cape Septic and Survey
618 Route 28
West Yarmouth, MA 02673
(508) 771-4200
allcapesepticOgmail.com
January 19, 2022 l Sheet 1 of 2 1 By. MAI Check: SM l Dwg. 0407
CONSTRUCTION NOTES
9.) ALL WORK SHALL CONFORM TO THE STATE ENMRONMENTAL CODE, TITLE 5 (310 CMR 15.000):
STANDARD REQUIREMENTS FOR THE SITING, CONSTRUCTION, INSPECTION. UPGRADE, AND
EXPANSION OF ON-SITE SEWAGE TREATMENT AND DISPOSAL SYSTEMS AND FLXR THE TRANSPORT
AND DISPOSAL OF SEPTAGE', AND THE LOCAL BOARD OF HEALTH REGULATIONS.
2.) ANY SEPTIC SYSTEM COMPONENT INSTALLED IN A LOCATION WHERE THERE IS POTENTIAL FOR.
VEHICLES OR HEAVY EQUIPMENT TO PASS OVER IT SHALL BE DESIGNED TO WITHSTAND AN H-20
LOADING IF UNDER AN IMPERVIOUS SURFACE, SYSTEM SHALL BE VENTED TO THE ATMOSPHERE.
3.) TO MINIMIZE UNEVEN SETTLING, SEPTIC TANKS AND D -BOX SHALL BE INSTALLED ON A STABLE
MECHANICALLY -COMPACTED BASE ON SX INCHES OF CRUSHED STONE,
4.) COVERS OVER THE INLET AND OUTLET TEES OF THE SEPTIC TANK, THE DISTRIBUTION BOX AND 11_O*
THE SOIL ABSORPTION SYSTEM SHALL BE RAISED TO W THIN 6" OF FINAL GRADE. LEACHING
FIELDS, TRENCHES. AND OTHER SOIL ABSORPTION SYSTEMS WITHOUT ACCESS MANHOLES SHALL
HAVE AT LEAST ONE (1) INSPECTION PORT CONSISTING OF PERFORATED 4" PVC PIPE PLACED
VERTICALLY TO THE BOTTOM OF THE SOIL ABSORPTION SYSTEM WITH A CAP, TIED WITH MAGNETIC
MARKING TAPE, ACCESSIBLE TO WITHIN 3" OF FINAL GRADE.
5.) PIPING SHALL CONSIST OF 4" SCHEDULE 40 PVC OR EQUIVALENT, PIPE SHALL BE LAID ON A
MINIMUM CONTINUOUS GRADE OF NOT LESS THAN 2X FROM THE BUILDING TO THE SEPTIC TANK,
AND NOT LESS THAN 1% OTHERWISE.
S.) DISTRIBUTION LINES FOR THE SOIL ABSORPTION SYSTEM SHALL BE 4" DIAMETER SCHEDULE 40
PVC (OR EQUIVALENT) LAID AT 0.005 FT/FT. UNLESS OTHERWISE NOTED, LINES SHALL BE CAPPED.
AT END OR AS NOTED.
7.) LINES FROM THE DISTRIBUTION BOX TO BE LEVEL FOR THE FIRST TWO (2) FEET BEFORE
PITCHING TO THE SOL ABSORPTION SYSTEM. DISTRIBUTION BOX SHALL BE WATER TESTED TO
ASSURE EVEN MSTRIBUTTON.
8.) GROUT TO BE USED AT ALL POINTS WHERE PIPES ENTER OR LEAVE :ALL CONCRETE STRUCTURES
IN ORDER. TO PROVIDE A WATERTIGHT SEAL,
9.) HEAVY EQUIPMENT SHALL NOT BE ALLOWED TO OPERATE OVER. THE LIMITS OF THE SEWAGE
DISPOSAL FIELD. DURING THE COURSE OF CONSTRUCTION OF THE SYSTEM.
10.) IN ACCORDANCE LITH 310 CMR -15.221, ALL SYSTEM COMPONENTS SHALL BE MARKED WITH
MAGNETIC MARKING TAPE,
11,) THERE ARE NO KNOWN WELLS OR WETLANDS WITHIN 150' OF THE PROPOSED SOIL ABSORPTION SYSTEM,
12.) FROM THE DATE OF THE. INSTALLATION OF THE SOL ABSORPTION SYSTEM UNTIL RECEIPT OF
THE CERTIFICATE OF COMPLIANCE, THE PERIMETER SHALL BE STAKED AND FLAGGED TO PREVENT
USE OF THE AREA THAT MAY CAUSE DAMAGE. TO THESYSTEM.
13.) THE DESIGNER WILL NOT BE RESPONSIBLE FOR THE SYSTEM AS DESIGNED UNLESS
CONSTRUCTED AS SHOWN ON PLAN. ANY CHANGES STALL 8E APPROVED IN WRITING. BY THE ENGINEER,
ME
'E,
16.) CONTRACTOR SHALLVERIFY THAT ALL WASTELINES ARE CONNECTED BY WATER TESTING
WITHIN THE DWELLING PRIOR TO INSTALLATION OF ANY SEPTIC COMPONENTS.
17.) CONTRACTOR SHALL VERIFY EXISTING INVERT ELEVATIONS PRIOR TO INSTALLATION OF ANY
',. SEPTIC SYSTEM COMPONENTS.
18.) TEST HOLES COMPLETED PER STATE ENVIRONMENTAL CODE, TITLE 5, SOILS CAN BE
VARIABLE AND TEST HOLE DATA IS NO GUARANTEE OF SOL CONDITIONS IN OTHER AREAS. IF
SOLS DIFFER FROM THOSE SHOWN IN THE SOILS LOGS, DESIGN ENGINEER IS TO INSPECT THE
SOLS PRIOR TO PROCEEDING PATH INSTALLATION OF ANY SEPTIC COMPONENTS.
TEST HOLE LOGS
Test Hole 7 (EL=1051)
Depth
Elev,
Layer
Soil Class
Soil Color
Other
0"-12"
9.5
A
Loamy Sand
IOYR 2/2
w n GEOTEXTILE
1043* Inspection Instoll
12"-30"
8.0
B
Loamy Sand
10YR 5/6
Liner
30"-120"
0.5
C
Fine Medium
2.5Y 6/4
70.12 9.95 ++++++++++++
•
0.5
+ to
a 9.85 + + + + 4 I , Iij+I++++++II X1-1/2"STOP
Sand
GAS BAFFLE
DB -3 H-20 + + + + . + + f + + + + (Double was )
Ground Water Found 0 84" EL = 3.5 No Mottling
EXCAVATION NOTES SEPTIC TANK CAPACITY PROVIDED: 1,500 GALLON SEPTIC TANK (PROPOSED)
9) EXCAHOLEVATE LOG))ALL AT APPROXIMATE OVE SOIL EVATIONO7I7ONFOR(A LAERALE DEEP OBSERVATION
ODIS DISTANCE 5' -
(WHERE POSSIBLE) INALL 'DIRECTIONS BEYOND THE OUTER PERIMETER OF THE LEACHING AREA.
2) MATTMATERIAL
R AND OTHER DELETERIOOF US UBSTANCES GRANULAR SAND
MEtTSFREE
THEFTEEXMTUORAL NIC
CRITERIA PUT FORTH IN SECTION 15.255(3) OF TITLE 5.
3) SCARIFY THE BOTTOM SURFACE OF THE EXCAVATION PRIOR TO PLACEMENT
OF FILL INTO THE RETAINING STRUCTURE.
4) PLACE FILL ONLY WHEN BOTTOM SURFACE IS DRY.
Test Hole 2 (EL=10.51)
Depth
Elev.
Layer
Soil Closs
Soil Color
Inspection Port
0"-10"
9.6
* +1 Box Cover
Loamy Sand
11.71
w n GEOTEXTILE
1043* Inspection Instoll
10"-33"
7.7
FABRIC
Port 40 Mil
n
IOYR 5/6
Liner
3 9,7 \ iL
10:555.01
o
70:3
70.12 9.95 ++++++++++++
•
0.5
+ to
a 9.85 + + + + 4 I , Iij+I++++++II X1-1/2"STOP
Medium Fine
GAS BAFFLE
DB -3 H-20 + + + + . + + f + + + + (Double was )
'
See Note
<
+ + + + + + + + + + + +
D -BOX /
Sand
9.2
9.z 16' x 30Leach Field
-f
j-.---12'* --1
1,500 GALLON WITH THREE 4" SCH 40 PERF. PVC PIPE
SEPTIC TANK
�SET AT 0,005 SLOPE ON 6" DOUBLE 5.1'
8't -^� WASHED 3/4"
TO 1-1/2" STONE 5,
FLOW PROFILE
NOT TO SCALE EL= 4.1 Adjusted Ground Water
EL= 3.5 Ground Water
/wlf
High Ground Water Adjustment
l(84")
EL= 0.5 Bottom Test Hole
Depth to Ground Water
EL = 3.5
Water Level Range Zane
Well MIW 29 Zone A
Current Water Depth for
Index We16.57 March 2020
SYSTEM DESIGN CALCULATIONS
Adjustment
+ 0,57
SEWAGE DESIGN FLOW: THREE BEDROOM DWELLING 0 110 GPD/BEDROOM = 330 GPD
Estimated High Ground
Water El = 4,1
(MINIMUM' DESIGN REflUIRED 330 GPD)
SEWAGE DESIGN FLOW PROVIDED: 16' x 30' WIDE LEACH FIELD
WITH THREE 4" PERFORATED PVC PIPE ON 6" STONE
Vt = [(30 x 16.0) = 480 SF x 0.74 = 355 GPD PROVIDED
355 GPD' PROVIDED > 330 GPD REQUIRED
SEPTIC TANK CAPACITY REQUIRED: 330 GPD X 200 = 660 (MINIMUM)
EXCAVATION NOTES SEPTIC TANK CAPACITY PROVIDED: 1,500 GALLON SEPTIC TANK (PROPOSED)
9) EXCAHOLEVATE LOG))ALL AT APPROXIMATE OVE SOIL EVATIONO7I7ONFOR(A LAERALE DEEP OBSERVATION
ODIS DISTANCE 5' -
(WHERE POSSIBLE) INALL 'DIRECTIONS BEYOND THE OUTER PERIMETER OF THE LEACHING AREA.
2) MATTMATERIAL
R AND OTHER DELETERIOOF US UBSTANCES GRANULAR SAND
MEtTSFREE
THEFTEEXMTUORAL NIC
CRITERIA PUT FORTH IN SECTION 15.255(3) OF TITLE 5.
3) SCARIFY THE BOTTOM SURFACE OF THE EXCAVATION PRIOR TO PLACEMENT
OF FILL INTO THE RETAINING STRUCTURE.
4) PLACE FILL ONLY WHEN BOTTOM SURFACE IS DRY.
Test Hole 2 (EL=10.51)
Depth
Elev.
Layer
Soil Closs
Soil Color
Other
0"-10"
9.6
A
Loamy Sand
1058 2/2
10"-33"
7.7
B
Loamy Medium
IOYR 5/6
Sand
33"-120"
0.5
C
Medium Fine
2.5Y 6/4
Sand
DATE OF TESTING: 04/16/20 Ground Water Found 0 84" EL = 3.5 No Mottling
SOIL EVALUATOR: DAVID FLAHERTY JR. - SE2755
WITNESS: MALLORY LANGLER, HA - YARMOUTH
PERCOLATION RATE: LESS THAN 2 MIN/INCH
PERC IN C LAYER (58" Deep)
B.
MOORE
No.39398
Proposed Site and Septic Plan
10 Berwick Road West, Yarmouth, MA
Prepared for:
Edwards Family Revocable Trust
Prepared by:
All Gape Septic and Survey
618 Route 28
West Yarmouth, MA 02673
(508) 771-4200
allcopesept icogmail.com
Dote: January 19, 2022
Sheet 2 of 2