Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. 22 Lot SI SS Zone of Contribution: In Out f Aereege 8,00.-)Sq:-Ft Commercial: Residential: // Street: I D 1 .e rwrc,- RI� Village: (A), L(AA.p-- 1.n._ Floor Plan: / #Bedrooms: 3 Owner: Tti✓D n vw Fc1 wa_►-ol_S Installer: Address: (D 6e,ea-vui[d1C, Phone: Phone: (5b. ) 23'i? -2.48-7 Builder: m 1 ` 't'U • (Oc4 vrLp Engineer: �,I �eft[U `r tSLAX V�,1� o i Address: I Z Izo bi v. LK j ,R,cr..g __-fi, , j-4 Phone: (Sbi5- �"}I • 4200 c Phone: t;Sa?s) "4. j - 15102 i N/A YES` NO C 1.Required#of copies received 2 i i-r.ti,t-te L---u„o....Q , 9 ✓ 2.Date of soils exam and percolation test not older than 2 years / ` 3.4-5 ft of naturally occurring pervious material,above water table ,,/ Z 4.Foundation 2 ft above high point of road H.P.: I0,01 Fnd:13 A Var.: / 0 5.Water line 10 ft from septic components Var.: f 4 6.Benchmark indicated and shown-NGVD if near wetlands ✓ CA R 7. Septic tank minimum 10 ft from foundation,deck Var.: z-p V 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: - 9.Leaching minimum 100 ft from wetlands Var.: ✓ Z 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: V -1 V 11.Tank/leaching minimum 10 ft from property line Var.: tz Cf @ 12. System meets all other setback requirements Var.: QO 13.Uses adjustment for maximum high groundwater Var.: ✓ �G 14.Leaching set 4-5 ft above adj. water or bottom of test hole Var.: ✓ 15. System not in top or subsoil(A,B horizons) 'remov / T� 16.Proposed contours are suitable -i �' 17. System meets slope requirements-min. 1/8", '4"preferred C CK 18. System meets breakout requirements PVC liner: Wall: ✓' C 19. Specified tee sizes are proper, gas baffle on outlet tee ✓ '�U J 20. Sewage is under 10,000 gpd for parcel V 21.No garbage disposal 112 ✓ 22. System adequately sized for its intended use ,�y / 41 23.Minimum 6"stone or compacted below tank and dbox �/ Z 24.Manhole covers within 6"of grade,pump chamber cover to grade ,/ R ci 25. Inspection port on plastic chambers/leach field "// 26. Electrical permit for pump chamber/Separate meter for duplexes ti; c 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size 0 28. Septic tank/pump chamber to be factory waterproofed / 29.Vent provided if leaching below 3 feet,under driveway/parking / V 30.Buoyancy calculations for tank/pump chamber ✓ E Al.E to inspect and certify soils: wall: commercial: / 3 . Engineer/Re 'stered Sanitarian and Land Surveyor stamps/signature YES >< ,V c 33. - oa ' g is subject to vehicular traffic,groundwater N f . X 34.Title V Application and permit fee,installer signature NI / 35.Foundation footing min 2 feet above adjusted ground water for new house ✓ 36.Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by:________& w . 6 03 01