HomeMy WebLinkAboutEngineer Plan28 4 ! N 5 m� N SILVER - LEAF LN. "n, LOCUS LOCATION MAP LOT 18 (18,610 SF) ASSESSORS MAP: 13 PARCEL: E 17 FLOOD ZONE: B _k 1s. s x4lo 00� rs. 6 s �ZD"Qe i MIN r� 14 a �I a -f'4. 3 KEY: EXISTING CONTOUR: - - -- PROPOSED CONTOUR: -.. .. .. . ................ EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25 TEST HOLE: * UTILITY POLE: -0- FENCE LINE: - HYDRANT: -b- RETAINING WALL: TREE: 0 DM #95=072 _ 014 F1) TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, PE WITNESS: AMY VON HONE, R.S. DATE: 7-21-95 PERCOLATION RATE: < 2 MIN/IN TH-1 TH-2 14.0 NO GROUNDWATER ENCOUNTERED i 14.5 \WATER MAIN 0,4� SHUT OFF O 0 0 14.5 Ay 9y 14.4 L.i`V/` it V d AY !AT DRANT TAG BOLT LEV. 17.1 / V� Q' SEPTIC SYSTEM DESIGN NOTES: 1. VERTICAL DATUM. ASSUMED FROM QUAD (NGVD +/-) 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS TO CONFORM WITH AASHTO H-10 LOADING SPECIFICATIONS. 5. PIPE PITCH = 1/4" PER FOOT, (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 3.0. 11. EXISTING CESS POOL(S) TO BE PUMPED AND REMOVED OR FILLED WITH SAND. 12. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. FLOW ESTIMATE: (3 BEDROOM DESIGN, MINIMUM) _�L BEDROOMS AT 110 GAL/DAY/BEDROOM = 330 GAL/DAY SEPTIC TANK: 330 GAL/DAY x 2 DAYS = 660 GAL USE 1500 GALLON SEPTIC TANK LEACHING AREA: USE TWO LEACHING TRENCHES (34' x, 25' x 2' DEEP,) SIDE AREA. -(34 + 2.5)2 x 2 = 146 (.74) = 108 CAL/DAY BOTTOM AREA: 34 x 2.4 = 85 SF (74) 63 _GAADAY TOTAL CAPACITY -'171 GAL/DAY x 2 TRENCHES = 342 CAL/DAY SEPTIC SYSTEM SECT I_/� 15.4 FIRST FLOOR 12.21 ELEti 12.8 ELEV. /// COVERS WITHIN 12" OF FINISHED GRADE ONINSPECTION COVER E WITHIN 6" OF GRADE) 1500 GAL ELEV SEPTIC TANK (6" OF STONE UNDER) TEE SIZES: INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN 47 11.64LID-BOX (6" OF ELEV. ELEV. STONE UNDER) 11.54 ELEV PROVED BY: DATE: Goo ,r.LN4Q. tI'ski o DEMAREST-McLELLAN ENGINEERING 24 SCHOOL STREET P.O. BOX 463 / WEST DENNIS, MASSACHUSETTS 02670 THOMAS MCLELLAN, P.E. JOHN Z. DAMAREST JR., P.L.S. DIN, KIT BR LR 2" PEASTONE 3/4" -1 1/2" WASHED STONE - 4" PERFORATED PVC PIPE , - ELEV: 11.87 y� 9.37 ELEV. USE TWO LEACHING TRENCHES (34' x 2.5' x 2' DEEP) (MIN. SPACE BETWEEN TRENCHES = 7.5) SITE AND SEWAGE PLAN LOCA TION.• 193 SILVER LEAF LANE WEST YARMOUTH MA PREPARED FOR: ANDRE CASTELLANO SCALE: 1" = 30' DATE: 7-27-95 REFERENCE: PLAN BOOK 116, PAGE 61 AUG 0 2 1995 -«,A! Tlif r.., - A HORIZON ELEV f0" LOAMY SAND B HORIZON LOAMY SAND 24' 2.5Y 6/6 12.0 Cl HORIZON MEDIUM SAND 42- 2.5Y 6/8 10.5 C2 HORIZON MED -COARSE SAND PERC - 7.0 84" 2.5Y 7/4 C3 HORIZON MEDIUM SAND 120" 2.5Y 7/1 4.0 NO GROUNDWATER ENCOUNTERED i 14.5 \WATER MAIN 0,4� SHUT OFF O 0 0 14.5 Ay 9y 14.4 L.i`V/` it V d AY !AT DRANT TAG BOLT LEV. 17.1 / V� Q' SEPTIC SYSTEM DESIGN NOTES: 1. VERTICAL DATUM. ASSUMED FROM QUAD (NGVD +/-) 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS TO CONFORM WITH AASHTO H-10 LOADING SPECIFICATIONS. 5. PIPE PITCH = 1/4" PER FOOT, (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 3.0. 11. EXISTING CESS POOL(S) TO BE PUMPED AND REMOVED OR FILLED WITH SAND. 12. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. FLOW ESTIMATE: (3 BEDROOM DESIGN, MINIMUM) _�L BEDROOMS AT 110 GAL/DAY/BEDROOM = 330 GAL/DAY SEPTIC TANK: 330 GAL/DAY x 2 DAYS = 660 GAL USE 1500 GALLON SEPTIC TANK LEACHING AREA: USE TWO LEACHING TRENCHES (34' x, 25' x 2' DEEP,) SIDE AREA. -(34 + 2.5)2 x 2 = 146 (.74) = 108 CAL/DAY BOTTOM AREA: 34 x 2.4 = 85 SF (74) 63 _GAADAY TOTAL CAPACITY -'171 GAL/DAY x 2 TRENCHES = 342 CAL/DAY SEPTIC SYSTEM SECT I_/� 15.4 FIRST FLOOR 12.21 ELEti 12.8 ELEV. /// COVERS WITHIN 12" OF FINISHED GRADE ONINSPECTION COVER E WITHIN 6" OF GRADE) 1500 GAL ELEV SEPTIC TANK (6" OF STONE UNDER) TEE SIZES: INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN 47 11.64LID-BOX (6" OF ELEV. ELEV. STONE UNDER) 11.54 ELEV PROVED BY: DATE: Goo ,r.LN4Q. tI'ski o DEMAREST-McLELLAN ENGINEERING 24 SCHOOL STREET P.O. BOX 463 / WEST DENNIS, MASSACHUSETTS 02670 THOMAS MCLELLAN, P.E. JOHN Z. DAMAREST JR., P.L.S. DIN, KIT BR LR 2" PEASTONE 3/4" -1 1/2" WASHED STONE - 4" PERFORATED PVC PIPE , - ELEV: 11.87 y� 9.37 ELEV. USE TWO LEACHING TRENCHES (34' x 2.5' x 2' DEEP) (MIN. SPACE BETWEEN TRENCHES = 7.5) SITE AND SEWAGE PLAN LOCA TION.• 193 SILVER LEAF LANE WEST YARMOUTH MA PREPARED FOR: ANDRE CASTELLANO SCALE: 1" = 30' DATE: 7-27-95 REFERENCE: PLAN BOOK 116, PAGE 61 AUG 0 2 1995 -«,A! Tlif r.., -