HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST /
Location: A.M. 3Lf Lot 2-0l Zone of Contribution: In Out--✓ Acreage tl1c(-) 5 F
Commercial: Residential: V
Street: S .1---4-71)."4-k-- Si
Village: Floor Plan: #Bedrooms: 2-
Owner:
Owner: -'n 1 Installer: C vit-
Address: _ Phone:
Phone:
Builder: Engineer: &-1-' • wow -5
Address: Phone:
Phone:
N/A YES NO
1. Required#of copies received V"
2. Date of soils exam and percolation test not older than 2 years
3.4-5 ft of naturally occurring pervious material,above water table
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ✓
5.Water line 10 ft from septic components Var.: ✓
6.Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.: G�1YT ✓
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9.Leaching minimum 100 ft from wetlands Var.: ✓
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well _ Var.: ✓
11.Tank/leaching minimum 10 ft from property line Var.: ✓
12. System meets all other setback requirements Var.:
13. Uses adjustment for maximum high groundwater Var.: `coTR
14. Leaching s- CP• ft above adj. water or bottom of test hole Var.! / '
15. System not in top or subsoil(A,B horizons) loyal
16.Proposed contours are suitable
17. System meets slope requirements-min. 1/8", 1/4"preferred ✓
18. System meets breakout requirements Wall:
19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel V
21.No garbage disposal
22. System adequately sized for its intended use
23.Minimum 6"stone or compacted below tank and dbox
24. Manhole covers within 6"of grade,pump chamber cover to grade ✓
25. Inspection port on plastic chambers/leach field V
26. Electrical permit for pump chamber/Separate meter for duplexes ✓
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size ✓
28. Septic tank/pump chamber to be factory waterproofed ✓
29. Vent provided if leaching below 3 feet,under driveway/parking
30.Buoyancy calculations for tank/pump chamber ✓
31. Engineer to inspect and certify soils: wall: commercial:
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature ,/
33. H-20 loading is subject to vehicular traffic, groundwater '/
34.Title V Application and permit fee,installer signature ✓
35.Foundation footing min. 2 feet above adjusted ground water for new house ✓/
36.Deed Restriction required max. #bedrooms: max. flow: gpd V
37. Check area lots for groundwater/Label groundwater in Assessor's Map V
Plan reviewed by: f fITO 1- ZZ . 6 03 01