Loading...
HomeMy WebLinkAboutEngineer PlanPermit valid for REPAIR OF SEP' IC SYSTEM ONLY, due to State and I,oval se{ is variances. Board of llealth i es iew anA »ppro�:d required for any future :ulditionslrrnuv»Uun./a eralions to sewage Wainer, soil/or structures7dnc ling. Yarmouth Ifealtb Depart APPROVEI EXISTING S.A.' TO BE REMOVED (SEE NOTE 17) HOUSE(7f7) (CRAWL) BENCHMARK -2 COR/3ETT. STEP EL=11.00 FLOOD ZONE DESIGNATION FEMA FLOOD MAP NO. 25001CO589J EFFECTIVE DATE: 7/16/2014 FEMA ZONE AE(EL 11) 51 MA M E BENCHMARK -1 MAG. NAIL SET EL.= 6.52 00 STRE'E'T 763 edge of -'SHELL,,:.,.'_ DRII/E"Y t S 85 21'S0u E 5' 61 Pavement )< 6.40 7.29 Vx " 8.38 �& LEGEND 5� Name — 8 ----- EXISTING CONTOUR J EXISTING SPOT GRADE X8,58 L I INSTALL POLY LINER g g TOP OF LINER, EL.=9.0 m BOTTOM OF LINER, ECO PROPOSED S.A,S. GW— 12' x 25' LEACH FIELD W/2 DISTRIBUTION LINES EXISTING S.A.' TO BE REMOVED (SEE NOTE 17) HOUSE(7f7) (CRAWL) BENCHMARK -2 COR/3ETT. STEP EL=11.00 FLOOD ZONE DESIGNATION FEMA FLOOD MAP NO. 25001CO589J EFFECTIVE DATE: 7/16/2014 FEMA ZONE AE(EL 11) 51 MA M E BENCHMARK -1 MAG. NAIL SET EL.= 6.52 00 STRE'E'T 763 edge of -'SHELL,,:.,.'_ DRII/E"Y t S 85 21'S0u E 5' 61 Pavement )< 6.40 7.29 Vx " 8.38 �& LEGEND CEDAR sr e — 8 ----- EXISTING CONTOUR x 10.98 EXISTING SPOT GRADE - —B/ -.W OVERHEAD WIRES GW— UNDERGROUND UNDERGROUND WIRES I"9n-w,x• —W— EXISTING WATER SERVICE _ �,. r — G ---- EXISTING GAS SERVICE BRADDOCK 'ST TEST PIT o z BENCHMARK . itc �44 3rJEXISTING SEPTIC TANK 'h10'(TO REMAIN) 10,TOPOF TANK, EL.9.981RDEN 0 • +101 1NV.(OUT)=8.65± 9J0 � 949 + LOT 162 4,750±S.F. SHED sD.00I x 9,00 3 0 M 0 JUN � � 2022 HEALTH DEPT OF PETER T. McENTEE CIVIL No. 35109 OWNER OF RECORD MARTINI, THOMAS J MARTINI, JANIS M 5 BRADDOCK STREET SOUTH YARMOUTH, MA 02664 I LOCUS MAP GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND. REGULATIONS EXCEPT AS REQUESTED BELOW: —310 CMR.15.405(1)(h): CONTENTS OF LOCAL UPGRADE APPROVAL 1) A 1' reduction to the required separation between adjusted high groundwater and bottom of S.A.S., for 4' of separation. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO. THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ELEVATIONS ARE BASED ON AN ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. THERE ARE NO ABUTTING WELLS WITHIN 100' OF THE PROPOSED S.A.S.. 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE DIRECTED BY THE APPROVING AUTHORITIES. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE .SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. 13. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED EXISTING SEPTIC SYSTEM COMPONENTS NOT SHOWN ON THE PLAN, 14. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY. 15. HOUSE LOCATION. IS TAKEN FROM CERTIFIED PLOT PLAN BY DOWN CAPE ENGINEERING, INC., YARMOUTH PORT, MA DATED MARCH 11, 2011. MAP ID: 34-201 PROPOSED SEPTIC SYSTEM UPGRADE PLAN 5 BRADDOCK STREET, WEST YARMOUTH, MA Prepared for: Robert B. Our Co., 24 Great Western Rd, Harwich, MA 02645 Engineering by: SCALE DRAWN JOB. NO. Engineering Works, Inc. 1"=20' P.T.M. 198-22 12 West Crossfield Rood, Forestdole, MA 02644 DATE CHECKED SHEET NO. (508) 477-5313 5/24/22 P.T.M. 1 of 2 NOTE: TO PREVENT BREAKOUT, THE CONTRACTOR SHALL INSTALL SEPTIC TANK IROPOSED D—BOXA 40 MIL POLY LINER LINER AS SHOWN ON SHEET 1 INSTALL RISERS & COVERS OVER INLET & STALL RISER & COVER TOP OF LINER, EL.=9.0 OUTLET AND SET TO 6" OF FINISH GRADE T TO 6" OF GRADE BOTTOM OF LINER, EL=6.0 ENTRY PROPOSED S.A.S. T.O.F. EL=11.61 INSTALL INSPECTION PORT (MIN.) 77=FF F.G. EL.=10.6* F.G. EL.=10.4± F.G. EL.=10.4± F.G. EL.=10.3± BEDROOM KIT/DIN AVRVA MAINTAIN 2% GRADE (MIN.) OVER S.A.S. 3'(max.) L = T L = 8' 4' DIAM. INSPECTION PORT, ® 5=1% (MIN) 4"SCH40 PV ® S=1% (MIN.) 12' 4"SCH40 PVC x 4 HIN FIELD W/2-4 PERFORATED IN S.A.S., SOLID 4 I ABOVE S.A.S., WITH SCREW CAP BATH 6" S T WITHIN 3' OF GRADE. tog s 6" TO CAPPED ENDS LIVING 14 EXISTING 48" LIQUID INVERT I SLOPE OF PERF. PIPE = 0.5% INV. EL.=8.20(END) ROOM BEDROOM LEVEL ADD INV.=8. PpOBOXED INV.=8.41 25' EFFECTIVE LENGTH GAS BAFFLE..... SOIL ABSORPTION SYSTEM (PROFILE) ..... INV.=8.65± (VERIFY) 3 OUTLETS INV —8 33 ENTRY EXISTING SEPTIC TANK FINISH GRADE NOTES EL.=10.3t(MIN.) 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPES & FLOOR PLAN INVERTS EXITING HOUSE, PRIOR TO INSTALLATION. ..'. 1: >,;; ,...:. �. ;.. ...• ,,: •:,,'A'.. •.' FILTER FABRIC 2) D -BOX.. SHALL BE SET LEVEL AND TRUE TO GRADE BF EAKOUT ELEV.=8.7 ON A MECHANICALLY COMPACTED STABLE BASE OR 8 TTOM ELEV.= 6' CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2). 4' MIN SEPARATION TO G.W. 3) INSTALL INLET & OUTLET TEES AS REQUIRED. AN 4' OF NATURALLY 12' EFFECTIVE WIDTH 3/4"-1 1/2"DOUBLE 4 GAS BAFFLE TO BE INSTALLED ON OUTLET TEE OCCU RING PERVIOUS SOILS WASHED STONE FROM !BH: SOIL ABSORPTION SYSTEM (SECTION) BOTTOM OF S.A.S. TO ( AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. ADJ. HIGH G.W. EL: 3.6 _ TOP OF PERF. PIPES ✓EXISTING HOUSE(#5) SEPTI SYSTEM PROFILE T,,o;F=lfst FF EL.=1726i 'CONC. DN. (CRAWL) SONO. FNDN. SOIL LOG DESIGN CRITERIA DATE: MAY 19, 2022 Q4.,' ti9� SOIL EVALUATOR: PETER McENTEE SE#1542 Q. WITNESS: JAY GARDINER HEALTH AGENT iN NUMBER OF BEDROOMS: 2 ELEV. TP DEPTH c0^ N SOIL TEXTURAL CLASS: CLASS L s.s FILL O ' lb �O 6' I ' DESIGN PERCOLATION RATE: <2 MIN/IN 7.9 B.. Ab PROP_S.A_S. DAILY FLOW: 220 GPD LOAMY SAND R/ t--25—�I DESIGN FLOW: 220 GPD 7.5 13" GARBAGE GRINDER: NO LOAM SAN BOTT. OF PERC L LEACHING AREA REQUIRED: (220 GPD) = 297.3 SF 1DYR 5/6� 22" S.A.S. LAYOUT 74 GPD/SF 56 36 C EXISTING SEPTIC TANK: 1000 GALLON CAPACITY MED. SAND PROPOSED SEPTIC SYSTEM UPGRADE PLAN PROPOSED D—:BOX: 1 INLET, 3 OUTLET (MIN,), H-10 tOYR 6/4 5 BRADDOCK STREET, WEST YARMOUTH, MA INSTALL AN 12' x 25' LEACH FIELD 3.6 ADJ, GW 60"75EYRX 5/8 3.0 S TG. GW 67" Prepared for: Robert B. Our Co., 24 Great Western Rd, Harwich, MA 02645 SIDEWALL AREA: NOT APPLICABLE 72" 2.61 Engineering by: SCALE DRAWN JOB. NO. BOTTOM AREA: 12' x 25' = 300 S.F. PERC RATE <2 MIN/IN. "B" HORIZON .... ...................300 S.F. TOTAL AREA: .....' STANDING GW, EL.=3.0 Works, Engmeenng Works, Inc. N.T.S. P.T.M. 198-22 ESTIMATED HIGH GW, EL.=3.6 (REDOX) 12 West Crossfield Road, Forestdole, MA 02644 DATE CHECKED SHEET N0. LEACHING CAPACITY = 0.74 GPD/SF x 300 SF = 222.0 GPD (508) 477-5313 5/24/22 P.T.M. 2 Of 2