HomeMy WebLinkAboutEngineer PlanTBM EL
Top of
N .80'35'20.
.o
/ 1g•0 1 21,
:ld30 H17y2H (19.5)
lZOZ Z Z ��� c,'". '. ; • ".' Testi
`n
o
S DB
Map 67
Parcel 159
LOCATION OF UTILITIES IS APPROXIMATE AND ALL
UNDERGROUND AND OVERHEAD UTILITIES MUST BE
DETERMINED IN THE FIELD PRIOR TO COMMENCEMENT
OF ANY WORK, THIS INCLUDES, BUT NOT LIMITED TO,
REQUESTS TO DIGSAFE, ANY PRIVATE UTILITY COMPANIES
AND THE LOCAL WATER DEPARTMENT,
Mop 67
Parcel 173
20.2
crete 1
120.0' E 1
1
0
gas Lot _ `� \ LOt 19 NID
Il
r------r---r---7
I T I Bath I I
I Kitchen Dining
I 1 Bed #1
I
IFomily I. L
1 --1--- TBed #21
I_ _ Living i Bed #3 1 1
i
L---- 1----r---I
�-` 15,000± Sq. Ft. 0 11 Q
1 1 0 1 0
11 11 O 0
House #29
Bedroom
II TOF EL 21.5t�1 II 11 6
�1 II 11 ` 11
ST
0
#1s11"11 �,oe �` cr 1 14
I Patio
Garage I o/W _ 1
1
� � 1
`a0
Map 67
Parcel 171
GRAPHIC SCALE
( IN FEET )
1 inch = 20 ft.
Floor Plans
N.T.S.
1.) Assessor's Map 67 Parcel
CJ 2.) Bk 31774 Pg. 56
O 3.) Plan Book 249 Page 111
S 5.) This property is in Flood
N Firm map 250001 CO587J
No
S
South Yarmouth, MA
172
Lot 387
Zone X
Dated: 7/16/14
Proposed Septic Plan
29 Captain Dore Road South Yarmouth, MA
Yarmouth Health Department
APPROVED
Prepared for:
isa Luz Thomas
Capt Dore Road
Yarmouth, MA 02664
Prepared by.
All Cape Septic LLC
618 Route 28
West Yarmouth, MA 02673
(508) 771-4200
ollcopesep t ic@gm oil, corn
Date: 05/11/22 Sheet 1 of 2 By: MA Check: SM I Project No. AC -451
CONSTRUCTION NOTES
1.) ALL WORK HALL CONFORM TO THE STATE ENNRONMENTAL CODE. TITLE 5 (310 CMR /
000):
STANDARD REQUIREMENTS FOR THE STING. CONSTRUCTION, INSPECTION, UPGRADE, AND
IE
EXPANSION OF ON-SITE SEWAGE TREATMENT AND DISPOSAL SYSTEMS AND FOR THE THAN
PORT
AND DISPOSAL OF SEPTAGE, AND THE LOCAL BOARD OF HEALTH REGULATIONS.
Other
2.) ANY SEPTIC SYSTEM COMPONENT INSTALLED IN A LOCATION WHERE THERE IS POTENT
L FOR
VEHICLES OR HEAVY EQUIPMENT TO PASS OVER IT HALL BE DESIGNED TO WITHSTAND AN
H-20
LOADING. IF UNDER AN IMPERVIOUS SURFACE, SYSTEM HALL BE VENTED TO THE ATMOSI
4ERL
3.) TO MINIMIZE UNEVEN SETTLING, SEPTIC TANKS AND D -BOX HALL BE INSTALLED ON A
STABLE
MECHANICALLY -COMPACTED BASE ON SIX INCHES OF CRUSHED STONE.
Loomy Sand
4.) COVERS OVER THE INLET AND OUTLET TEES OF THE SEPTIC TANK, THE DISTRIBUTION
X. AND 19_0t
THE SOIL ABSORPTION SYSTEM HALL BE RAISED TO WITHIN 6" OF FINAL GRADE. LEACHII
G
FIELDS. TRENCHES. AND OTHER SOIL ABSORPTION SYSTEMS WITHOUT ACCESS MANHOLES S
ALL
HAVE AT LEAST ONE (1) INSPECTION PORT CONSISTING OF PERFORATED 4" PVC PIPE PLA(
--D
VERTICALLY TO THE BOTTOM OF THE SOIL ADSORPTION SYSTEM WITH A CAP, TIED WITH M
GNETIC
MARKINGTAPE, ACCESSIBLE TO. WITHIN 3" OF FINAL GRADE.
E
5.) PIPING SHALL CONSIST OF 4" SCHEDULE 40 PVC OR EOUIVALENT. PIPE SHALL BE LAI
ON A
MINIMUM CONTINUOUS GRADE OF NOT LESS THAN 2% FROM THE BUILDING TO THE SEPTIC
ANK,
AND NOT LESS THAN 1% OTHERWISE.
TTLIN
LINES FOR THE SOIL ABSORPTION SYSTEM SHALL BE DIAMETER
(EQUIVALENT)
PVC LAID AT 0.005 FT/IT. UNLESS OTHERWISE NOTED
CLINES H
. ALL BE
APPED
AT END OR AS NOTED.
7.) LINES FROM THE DISTRIBUTION BOX TO BE LEVEL FOR THE FIRST TWO (2) FEET BEFOR
PITCHING TO THE SOL ABSORPTION SYSTEM. DISTRIBUTION BOX HALL BE WATER TESTED
TO
ASSURE EVEN DISTRIBUTION.
8J GROUT TO BE USED AT ALL POINTS WHERE PIPES ENTER OR LEAVE ALL CONCRETE ST
UCTURES
IN ORDER TO PROVIDE A WATERTIGHT SEAL.
9.) HEAVY EQUIPMENT HALL NOT BE :ALLOWED TO OPERATE OVER THE LIMITS OF THE SEI
AGE
DISPOSAL FIELD DURING THE COURSE OF CONSTRUCTION OF THE SYSTEM.
10.) IN ACCORDANCE WITH 310 CMR 15.221, ALL SYSTEM COMPONENTS SHALL BE MARKED
wTH
MAGNETIC MARKING TAPE.
11.) THERE ARE NO KNOWN WELLS OR WETLANDS WITHIN 150' OF THE PROPOSED SOL ASS
IRPTION SYSTEM.
12.) FROM THE DATE OF THE INSTALLATION OF THE SOL ABSORPTION. SYSTEM UNTIL RECEI
T OF
THE CERTIFICATE OF COMPLIANCE, THE PERIMETER HALL DE STAKED AND FLAGGED TOP
VENT
USE OF THE AREA THAT MAY CAUSE DAMAGE TO THE SYSTEM.
13.) THE DESIGNER WILL NOT BE RESPONSIBLE. FOR THE SYSTEM AS DESIGNED UNLESS
CONSTRUCTED AS SHOWN ON PLAN. ANY CHANGES SHALL BE APPROVED IN WAITING BY I
iE ENGINEER,
14.) THE BOARD OF HEALTH REQUIRES INSPECTION OF ALL CONSTRUCTION BY AN AGENT 0
THE
BOARD OF HEALTH AND THE DESIGNER. THE DESIGNER SHALL CERTIFY IN WRITING THAT 7
IE
SEWAGE DISPOSAL SYSTEM WAS INSTALLED IN ACCORDANCE PATH THE TERMS OF THE PERt
IT
AND ME APPROVED PLANS 48 HOURS ADVANCE NOTICE IS REQUESTED.
Other
15.) LOCATION OF UTILITIES IS APPROXIMATE AND CONTRACTOR HALL BE RESPONSIBLE FO
18.7
DETERMINING THE LOCATION OF ALL UNDERGROUND AND OVERHEAD UTILITIES PRIOR TO
Fill
COMMENCEMENT OF ANY WORK. THIS INCLUDES, BUT IS NOT. UNTED TO, REOUESTS TO DIG
AFE,
ANY PRIVATE UTILITY COMPANIES, AND THE LOCAL WATER DEPARTMENT.
18:4
16.) CONTRACTOR HALL VERIFY THAT ALL WASTELINES ARE CONNECTED BY WATER TESTIN
Loomy Sand
WITHIN THE DWELLING PRIOR TO INSTALLATION OF ANY SEPAL COMPONENTS.
17.) CONTRACTOR HALL VERIFY E)OSTING INVERT ELEVATIONS PRIOR TO INSTALLATION OF
Y
SEPTIC SYSTEM COMPONENTS.
Loamy Sand
18.) TEST HOLES COMPLETED PER STATE ENVIRONMENTAL CODE, ATLE 5. SOILS CAN BE
VARIABLE AND TEST HOLE DATA IS NO GUARANTEE OF SOL CONDITIONS IN OTHER AREAS
IF
SOLS DIFFER FROM THOSE SHOWN IN THE SOLS LOGS, DESIGN ENGINEER IS TO INSPECT TI
E
SOILS PRIOR TO PROCEEDING WITH INSTALLATION OF ANY SEPTIC COMPONENTS.
19.) EXISTING SEPTIC COMPONENTS TO BE LOCATED; PUMPED DRY, FILLED WITH CLEAN SANAND
ABANDONED IN PLACE OR REMOVED AS REQUIRED. AREA TO BE COMPACTED TO MINIMIZE
TTLIN
EXCAVATION NOTES
1) EXCAVATE ALL HOLE LOG) FORMA LATERAL ATERIAL BDISTANE OFOVE SOIL 5- 5'(WFIEN C F
(WHERE. POSSIBLE) IN ALL DIRECTIONS BEYOND. THE
2) MATTER AND OTHHER DELOETERIOUS SUBSTANCES,UWI
CRITERIA PUT FORTH IN SECTION 15.255(3) OF TIT(
3) FFYTTBHTEAISTUEXCAVATI(
OF FILL THE RETAINING STRUCTURE.
4) PLACE FILL ONLY WHEN BOTTOM SURFACE IS DRY.
PRIOR TO
20.03
0
GAS
c.................. I.....
EXISTING
1,000 GALLON
SEPTIC TANK
a
See Note
MIN.
17.5
DB -3 H-20
D -BOX
1 11'3
--12't ---}
FLOW PROFILE
NOT TO SCALE
High Ground Water Adjustment
REFERENCE WELL = MIW-29 ZONE B
APRIL 2022 LEVEL = 7.56' ADJUSTMENT FACTOR = 1.9'
TEST HOLE LOGS
Test Hole i (EL=19.5±)
by:
Depth
Elev.
Layer
Soil Class
Soil Color
Other
Q--9"
18.7
Date: May 11,
Fill
9"-13"
18:4
A.
Loomy Sand
1QYR 2/2
13"-31"
16.9
B
Loamy Sand
1OYR 5/8
31"-126"
9.0
C
Medium
10YR 6/4
Sand
Ground Water Found 0 122" EL = 9.3 No Mottling
Inspection Port
Box Cover
Inspection GEOTEXTILE
Port FABRIC
+ + + + + + + f I + + + + 3/4" to
++++ 1 I I I I 1 I 1 I (0T-1/2" STONE
+ + + + + + + t + + + + + + + (Double wash)
+ + + + + + + +
18.4
16' X 30' Leach Field
WITH THREE 4" SCH 40 PERF. PVC PIPE
SET AT 0.005 SLOPE ON 6" DOUBLE 5.2'
WASHED 3/4" TO 1-1/2" STONE
EL- 11.2 Adjusted Ground Water
EL=. 9.3 Ground Water
EL- 9.0 Bottom Test Hole
SYSTEM DESIGN CALCULATIONS
SEWAGE DESIGN FLOW: THREE BEDROOM DWELLING 0 110 GPD/BEDROOM = 330 GPD
(MINIMUM DESIGN REQUIRED 330 GPD)
SEWAGE DESIGN FLOW PROVIDED: 16' x 30' WIDE LEACH FIELD
WITH THREE 4" PERFORATED PVC PIPE ON 6" STONE
Vt =.[(30 x 16.0) = 480 SF x 0.74 = 355 GPD PROVIDED
355 GPD PROVIDED > 330 GPD REQUIRED
SEPTIC TANK CAPACITY REQUIRED: 330 GPD X 200 = 660 (MINIMUM)
SEPTIC TANK CAPACITY PROVIDED: 1,000 GALLON SEPTIC TANK (EXISTING)
DATE OF TESTING: 05/04/22
SOIL EVALUATOR: MARK POLSELLI
WITNESS: PHIL RENAUD - YARMOUTH HEALTH AGENT
PERCOLATION RATE: LESS THAN 2 MIN/INCH
PERC IN C LAYER (62" Deep)
OF THE LEACHING AREA.
Proposed Septic
29 Captain Dore
South Yarmouth,
Plan
Prepared for:
Eliza Luz Thomas
Prepared
by:
All Cape Septic
and Survey
618 Route
28
West Yarmouth,
MA 02673
(508) 771-4200
allcapesep ticogmail, com
Date: May 11,
2022
Sheet 2 of 2