HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot -73 Zone of Contribution: In Out k Acreage /6,4.761. SF
Commercial: Residential: t..---
Street: Se, 7A-0-k .4- err-A ic-
Village: &. tS-T Floor Plan: 00 #Bedrooms: `f
Owner: C I V TC / Installer:
Address: Phone:
Phone:
Builder: A/ Aut. t?e-d-,F Engineer: 73 S C_
Address: Phone:
Phone:
N/A YES NO
✓
1. Required#of copies received
2. Date of soils exam and percolation test not older than 2 years
3.4-5 ft of naturally occurring pervious material,above water table V
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ,/
5.Water line 10 ft from septic components Var.: V
6. Benchmark indicated and shown-NGVD if near wetlands V
7. Septic tank minimum 10 ft from foundation d c- Var.:
8.Leaching minimum 20 ft full, 15 ft cra , 10 ft slab Var.: -Coo-y,c.e.i
9.Leaching minimum 100 ft from wetlands Var.:ok./as`1b u,Er. ,ver So' Tc.) cop,..-r*& IsA.A4c 1'
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ,/
11.Tank/leaching minimum 10 ft from property line Var.: /
12. System meets all other setback requirements Var.: ea-frame, 64'-J -
13. Uses adjustment for maximum high groundwater Var.: V
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var. V
15. System not in top or subsoil(A,B horizons)o1;5' remov ✓
16.Proposed contours are suitable ✓
17. System meets slope requirements-min. 1/8", 1/4"pre ✓
18. System meets breakout requirements PVC liner: Wall: 4/-
19. Specified tee sizes are proper,gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel
/
21.No garbage disposal
22. System adequately sized for its intended use /2o -s c..7.4--ver 4/
23.Minimum 6"stone or compacted below tank and dbox '7 _,#J -- 4..../-
24.
/24. Manhole covers within 6"of grade,pump chamber cover to grade e"
25. Inspection port on plastic chambers/leach field V
26. Electrical permit for pump chamber/Separate meter for duplexes V
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size ✓
28. Septic tank/pump chamber to be factory waterproofed -V
29. Vent provided if leaching below 3 feet,under driveway/parking ✓
30. Buoyancy calculations for tank/pump chamber V
31. Engineer to inspect and certify soils: wall: commercial: r/
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature A/
33.11-20 loading is subject to vehicular traffic,groundwater r/
34.Title V Application and permit fee,installer signature
1.,-
35.Foundation footing min.2 feet above adjusted ground water for new house
36.Deed Restriction required max. #bedrooms: max. flow: gpd I
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by'_ , ' ik dr /