Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTHfl-v (, �� //"' SEWAGE PLAN REVIEW CHECKLIST Location: A.M. (1 Lot (P Zone of Contribution: InC Out Acreage Commercial: Residential: - Street: 7/ W LE. 6 a,( j, (.....) #Village: �! Gd L2,:��� / Floor Plan: Bedrooms: Owner: 6,C// S Installer: T Address: Phone: Phone: Builder: Engineer: / h re-{ r /Gee4/- Address: Z Phone: --36 } _ �l S 9 Phone: Wtii�. _ `i vcaevcuS` -��(f� �' S� -14 (7011 isS j r1. YES ' Nb 1. Required# of copies received v 2. Date of soils exam and percolation test not older than 2 years +../ 3. 4-5 ft of naturally occurring pervious material, above water table 1/ 4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: 1...--- 5. �5. Water line 10 ft from septic components Var.: (. 6. Benchmark indicated and shown-NGVD if near wetlands t/ 7. Septic tank minimum 10 ft from foundation, deck Var.: L/ 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9. Leaching minimum 100 ft from wetlands Var.: / �� 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well, Var.: J l ( h� \ t� 11. Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: t/ 13. Uses adjustment for maximum high groundwater Var.: i/ 14. Leaching set 4-5 ft above adj. water or bottom/of test hole"Var.: ,-, 15. System not in top or subsoil(A,B horizons)4\5' removal � i z'( y�,,,t;,.y- f G,/ 16. Proposed contours are suitable 17. System meets slope requirements-min. 1/8", VI"preferred 18. System meets breakout requirements PVC liner: Wall: ✓� 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel k/' 21.No garbage disposal l� 22. System adequately sized for its intended use 1/ 23. Minimum 6"stone or compacted below tank and dbox l� 24. Manhole covers within 6"of grade, pump chamber cover to grade I 25. Inspection port on plastic chambers/leach field 26. Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2" line,weep hole,check valve, tee in dbox, pump size 28. Septic tank/pump chamber to be factory waterproofed 29. Vent provided if leaching below 3 feet, under driveway/parking 30. Buoyancy calculations for tank/pump chamber 31. Engineer to inspect and certify soils: wall: commercial: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33. H-20 loading is subject to vehicular traffic, groundwater 34. Title V Application and permit fee, installer signature 35. Foundation footing min. 2 feet above adjusted ground water for new house 36. Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: 6/03/03