Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. P3? Lot_ 1 33 Zone of Contribution: hi Out �Acreage/0 3 0 9 Street: 19 Commercial: - Residential: 3. � TL Village: Floor Plan: V # Bedrooms: 3 Owner: C k_r f s 2 , Installer: C kaS 'Me f oh4.4... Address: _ Phone: Phone: Builder: Engineer: Pt C-1 INN S Ct e c-'-g r"9IN Address: _ _ Phone: Phone: N/A YES r NO -� 1. Required#of copies received I - 2. Date of soils exam and percolation test not older than 2 years 3. 4-5 ft of naturally occurring pervious material, above water table 4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5. Water line 10 ft from septic components Var.: 'k. 6. Benchmark indicated and shown-NGVD if near wetlands V 7. Septic tank minimum 10 ft from foundation, deck Var.: ✓ 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: tr' 9. Leaching minimum 100 ft from wetlands Var.: 10. Leaching minimum 150 ft from drinking well 25 ft irrigation well Var.: Y V ! ------ 11. Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: V l3. Uses adjustment for maximum high groundwater Var.: 14. Leaching set 4-5 ft above adj. water or bottom of test hole r.. - 15. System not in top or subsoil (A,B horizons) or 5' removal / 16. Pro.osed contours are suitable l/. 17. System meets slope requirements-min. 1/8", !!"preferred 18. System meets breakout requirements PVC liner: -_ Wall: ; �- 19. Specified tee sizes are proper, gas baffle on outlet tee j ,� 20. Sewage is under 10,000 gpd for parcel 21. No garbage disposal ---- ---- -- 22. System adequately sized for its intended use 23. Minimum 6"stone or compacted below tank and dbox 7 24. Manhole covers within 6"of grade, pump chamber cover to grade 25. Inspection port on plastic chambers/leach field 26. Electrical permit for pump chamber/Separate meter for duplexes v 27. Pump system-2"line,weep hole,check valve, tee in dbox, pump size ✓ -' 2S. Se tic tank/pump chamber to be factory waterproofed ` 29. Vent provided if leaching below 3 feet,under driveway/parking V 30. Buoyancy calculations for tank/pump chamber --31. Engineer to inspect and certify soils: wall: commercial: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature j t-/V/k7' _I 33. H-20 loading is subject to vehicular traffic, groundwater 34. Title V Application and permit fee, installer signature 1.7 35. Foundation footing min. 2 feet above adjusted ground water for new house L/ 36. Deed Restriction required max. #bedrooms: max. flow: ____ gpd 1 (/ 37. Check area lots for groundwater/Label groundwater in Assessor's Map I Plan reviewed b_v: s G0:01