HomeMy WebLinkAboutAir Leakage Report - 80 Wilfin Rd YarmoutghAir Leakage Property New Residence 80 Wilfin Rd. South Yarmouth, MA 02664 Weather:Barnstable AP, MA 80 Wilfin Rd 6397177.178.80WilfinRdYarmouth .16.0.6.TC.MEB.blg Organization Cape Cod HERS Raters (508)737-8011 Chris Picariello Builder Josh Bilotta Whole House Infiltration ASHRAE 62.2 - Ventilation Requirements The ASHRAE 62.2 flow rates shown above are the CONTINUOUS mechanical fresh air ventilation which will meet the 'whole-building' requirement under that version of the standard. The 62.2-2013 rate incorporates any appropriate 'infiltration credit'. Intermittent mechanical ventilation may be used if the flow rate is adjusted accordingly. For example, the runtime can be reduced to 12 hours per day using a doubled flow rate, as long as the system provides ventilation at least once every 3 hours. For more detail, refer to the appropriate standard. REM/Rate - Residential Energy Analysis and Rating Software v16.0.6 This information does not constitute any warranty of energy costs or savings. © 1985-2021 NORESCO, Boulder, Colorado. HERS Confirmed 2022-08-10 Rating No:178 Rater ID:6397177 Duct Leakage Ventilation Blower Door Test Heating Cooling Natural ACH 0.07 0.06 ACH @ 50 Pascals 0.81 0.81 CFM @ 25 Pascals 257 257 CFM @ 50 Pascals 403 403 Eff. Leakage Area (sq.in)22.1 22.1 Specific Leakage Area 0.00005 0.00005 ELA/100 sf shell (sq.in)0.39 0.39 CFM50/sf shell 0.07 0.07 Leakage to Outside Units duct CFM @ 25 Pascals 2 CFM25 / CFMfan 0.0012 CFM25 / CFA 0.0007 CFM per Std 152 N/A CFM per Std 152 / CFA N/A CFM @ 50 Pascals 3 Eff. Leakage Area (sq.in)0.17 Thermal Efficiency N/A Total Duct Leakage Units CFM25/CFA Total Duct Leakage 0.0332 Mechanical Supply Only ASHRAE ASHRAE Adj. Sensible Recovery Eff. (%)0.0 62.2-2010 62.2-2013 Adj. Total Recovery Eff. (%)0.0 Rate (cfm)210 52 90 Hours/Day 10.3 24.0 24.0 Fan Watts 40.0 Cooling Ventilation Natural Ventilation