HomeMy WebLinkAboutBLDE-23-000969 SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE 8 DESCRIPTION •SYSTEM SIZE:5475W DC,3800W AC •ALL WORK SHALL COMPLY WITH MA 9th Ed.CMR 780(2015 IRC/IBC/IEBC), I , SOLAR MODULES •MODULES:(15)LONG!GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION SERVICE ENTRANCE PV-1.0 COVER SHEET LTD:LR4-60HPH-365M INSTRUCTIONS. L J u 1 u u u PV-2.0 SITE PLAN •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. • • • o, i PV-3.0 LAYOUT MP SE3800H-USMN MAIN PANEL p •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. • PV-4.0 ELECTRICAL SEE DETAIL SNR-DC-00436 4 SNR MOUNT •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP SUB-PANEL SNR MOUNT&SKIRT PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER CHIMNEY •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. ATTIC VENT •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER FLUSH ATTIC VENT MODULES,ARE CLASS A FIRE RATED. .. PVC PIPE VENT •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). . . T-VENT •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). IAC AC DISCONNECT(S) SATELLITE DISH •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC •11.43 AMPS MODULE SHORT CIRCUIT CURRENT. 0 DC DISCONNECT(S) FIRE SETBACKS •17.85 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)&690.8(b)]. CB IQ COMBINER BOX HARDSCAPE •PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE INTERIOR EQUIPMENT —PL— PROPERTY LINE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION L J SHOWN AS DASHED SCALE:NTS A AMPERE s u n r u n AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION #180120 DC DIRECT CURRENT 3'5111.1e!e: (E) EXISTING 695 MYLES STANDISH BLVD,TAUNTON.MA,02780-7331 Province?ov;n ESS ENERGY STORAGE SYSTEM PHONE 0 FAX EXT EXTERIOR INT INTERIOR CUSTOMER RESIDENCE: F-i u, Cie MSP MAIN SERVICE PANEL 23 CAPTAIN NICKERSON RD, C Bey 1 18re1 (N) NEW YARMOUTH,MA,02664 '^' f!- NTS NOT TO SCALE OC ON CENTER TEL.(508)221-5748 PRE-FAB PRE-FABRICATED AP N:YARM-000078-000118 Cr cans PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC PROJECT NUMBER: rri T �y T / RSD RAPID SHUTDOWN DEVICE 223R-023CARE r apta r Nickerson TL TRANSFORMERLESS (415)580-6920 ex3 k S.,ut Yarmouth TYP TYPICAL DESIGNER: Ma,!1:)ee V VOLTS SUNIL PASWAN W WATTS _ SHEET REV NAME DATE COMMENTS COVER SHEET Fa!nu,ah REV:A 8/22/2022 p Oak Bluffs PAGE PV-1.0 `- C:),.,DG7___\23- OW )( 3 • ARRAY TRUE MAG PV AREA SITE PLAN DETAIL-SCALE=1/16"=V-0"ail, PITCH AZIM AZIM (SOFT) AR-01 30° 170° 184° 294.1 \f►JI Pl CAPTAIN NICKERSON RD .. • ., . - pl - Pl ---------------A IPL ;._ ,.,„ ;„_ . , . I , \AC ns \ . a (E)RESIDENCE \ _. r (N)ARRAY AR-01 - s u n r u n #180120 ,_ 6135 MYLES STANDISH BLVO,TAUNTON,MA 0,80,, PHONED VAX 0 \ , -59" CUSTOMER RESIDENCE: MICHAEL CAREY 23 CAPTAIN NICKERSON RD, YARMOUTH,MA,02664 , i TEL.(508)221-5748 APN:YARM-000078-000118 r PI- ----------- PROJECT NUMBER: Pl223R-023CARE Pl -------\_________ DESIGNER: (415)580E920 ax3 Pl -------------- SUNIL PASWAN SHEET SITE PLAN REV:A 8/22/2022 PAGE PV-2.O ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:30 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 2-Story 2X6 RAFTERS 10'-8" 16" COMP,SEE DETAIL SNR-DC-00436 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED 140 MPH 3-SEC GUST. S.S.LAG SCREWS: D1-AR-R-01-SCALE:3/16"=7'-0,, 5/16":2.5"MIN EMBEDMENT 0° STRUCTURAL NOTES: D PITCH:30° • INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. • IF ARRAY(EXCLUDING SKIRT) IS WITHIN 12"BOUNDARY REGION OF ANY ROOF PLANE EDGES(EXCEPT VALLEYS), 13'-8" THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS FOLLOWS: ••ALLOWABLE ATTACHMENT [+ _. L+ ---C3 _.. E3-- --El ❑ _... .. SPACING INDICATED ON PLANS TO BE REDUCED BY 50% • '. I ••ALLOWABLE OVERHANG INDICATED ON PLANS TO BE -..#.}..... f3. ,... fl..,, + �........ . . ....... . .,._.. 1/5TH OF ALLOWABLE ATTACHMENT SPACING 10'-4" jl, 1 INDICATED ON PLANS 5.4 TYP �t 1 __ ___C2 C. sunrun 3,-2" #180120 25'-10" 29'-1" 10'-1" MIS MYLES STANDISH BLVD.TAUNTON.MA A2780.7331 PHONE 0 FAX 0 CUSTOMER RESIDENCE: MICHAEL CAREY 23 CAPTAIN NICKERSON RD, YARMOUTH,MA,02664 TEL.(508)221-5748 APN:YARM-000078-000118 PROJECT NUMBER: 223R-023CARE STRUCT oNLS NOFMgs, DESIGNER: (415)580-6920 ex3 �� 41 SUNIL PASWAN 49 VINCENT av, - - o MWUMVANEZA N SHEET CIVIL LAYOUT N. 9jJ/ a�N 4- REV:A 8/22/2022 SEE SITE PLAN FOR NORTH ARROW e'l orattSC'. PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE 0METER#: M EVERSOURCE2366302 UTILITY NOTE:TOTAL PV BACKFEED=20A GRID USED FOR INTERCONNECTION SUPPLY SIDE TAP CALCULATIONS I 4 (N)LOCKABLE SOLAREDGE TECHNOLOGIES: EXISTING t00A BLADE TYPE (N)MA SMART MAIN BREAKER FUSED AC UTILITY SE3800H-USMN WITH DISCONNECT REVENUE REVENUE GRADE METERING 1 METER 3800 WATT INVERTER JUNCTION BOX PV MODULES 3 3. 2 OR EQUIVALENT 1 LONGI GREEN ENERGY TECHNOLOGY EXISTING / CO LTD:LR4-60HPH-365M 100A MAIN _ ��, O �/-' _ ,_,i �— '8// (15)MODULES �, PANEL - OPTIMIZERS WIRED IN: FACILITY 20A FUSES I ` I (1)SERIES OF(15)OPTIMIZERS LOADS L GRoLIND SQUARED 240V METER SOCKET LOAD RATED DC DISCONNECT D222NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS 3R,60A UTILITY SIDE OF CIRCUIT COMPLIANT P401 120/240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER s u n ru n 2 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 3 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 SOS KYLES STANDISH..7AUNTON MA 02780.73, PHONE F.o CUSTOMER RESIDENCE: MICHAEL CAREY 23 CAPTAIN NICKERSON RD, MODULE CHARACTERISTICS YARMOUTH,MA,02664 LONGI GREEN ENERGY TECHNOLOGY CO LTD: P401 OPTIMIZER CHARACTERISTICS: TEL.(508)221-5748 LR4-6OHPH-365M: 365 W MIN INPUT VOLTAGE: 8 VDC APN:YARM-000078-000118 OPEN CIRCUIT VOLTAGE: 40.7 V MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: MAX POWER VOLTAGE: 34.2 V MAX INPUT ISC: 11.75 ADC 223R-023CARE SHORT CIRCUIT CURRENT: 11.43 A MAX OUTPUT CURRENT. 15 ADC DESIGNER: (415)580-6920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 SUNIL PASWAN SYSTEM SIZE: 5475 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 15 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:A 8/22/2022 SYSTEM OPERATING CURRENT: 14.41 A SYSTEM SHORT CIRCUIT CURRENT: 15 A PAGE PV-4.0 ® INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR ELECTRICAL SHOCK HAZARD IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE 400 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS,COLORS AND SYMBOLS. TERMINALS ON LINE AND LOAD •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2020:690.53 INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2020:690.13(B) WARNING: PHOTOVOLTAIC POV DER SOURCE LABEL LOCATION: DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS. ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020:690.31(D)(2),IFC 2012: SYSTEM 605.11.1.4 LABEL LOCATION: cAuTioN ■ UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S):NEC 2020705.12(C) MULTIPLE SOURCES OF POWER r DO NOT RELOCATE THIS Z\ OVERCURRENT DEVICE LABEL LOCATION: . INSTALLED WITHIN 3'OF RAPID SHUT DOWN LABEL LOCATION: SWITCH PER CODE(S):NEC 2020:690.56(C)(2),IFC s u n r u n ADJACENT TO PV BREAKER AND ESS 2012:605.11.1,IFC 2018:1204.5.3 ;---- OCPD(IF APPLICABLE). PERCODE(S):NEC 2020: 4" SOLAR PANELS ON ROOF 705.12(8)(3)(2) A • #180120 SOLAR PV SYSTEM EQUIPPED .._ ABS M Ess,p ps a o,,q MON,Mq.Oz,•°,,, PHOTOVOLTAIC SYSTEM WITH RAPID SHUTDOWN f MAIN PANEL(INT) PHONE 0 COMBINER PANEL FA"0 DO NOT ADD LOADS ^I CUSTOMER RESIDENCE: SERVICE ENTRANCE MICHAEL CAREY LABEL LOCATION: 23 CAPTAIN NICKERSON RD, PHOTOVOLTAIC AC COMBINER(IF FUSED AC DISCONNECT YARMOUTH,MA,02664 APPLICABLE). 3" TURN RAPID SHUTDOWN PER CODE(S):NEC 2020:705.12(D)(2)(3)(c) SWITCH TOTHE OFPVI OMili —PV PRODUCTION METER TEL.(508)221-5748 POSITION TO SHUT DOWN —INVERTER (EXT) APN:YARM-000078-000118 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE PROJECT NUMBER: MAXIMUM AC OPERATING CURRENT:15.83 AMPS SHOCK HAZARD IN THE ARRAY. Ir. 223R-023CARE NOMINAL OPERATING AC VOLTAGE: 240_ VAC DESIGNER: (415)580-6920 683 LABEL LOCATION: 23 CAPTAIN NICKERSON RD, YARMOUTH, MA, 02664 SUNILPASWAN AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. SHEET PER CODE(S):NEC 2020:690.54 LABEL LOCATION: PER CODE(S):NEC 2020'705.10,710.10 SI GNAG E ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV:A 8/22/2022 PER CODE(S):NEC 2020:690.56(C) PAGE PV-5.0