Loading...
HomeMy WebLinkAboutBLDE-23-000918 ,/ -4 /�� Commonwealth of Official Use Only —_ Massachusetts Permit No. BLDE-23-000918 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:8/22/2022 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 22 OLD SAGA DR Owner or Tenant JEAN CHARLES Telephone No. Owner's Address Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system (18 Panels 6.570 KW)(NO ESS) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiatine Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons , KW No.of Self-Contained Totals: Detection/Alertine Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Signs No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 Commonwealth o/MaJJachuaette Official Use Only *=a cc�� Permit No. ��Y / l g c ;\ .2 epartment o/Jiro Seruice3 Occupancy and Fee Checked BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 08/17/2022 City or Town of: Yarmouth To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number)22 Old Saga Rd, Yarmouth MA 02664 Owner or Tenant Jean Charles Telephone No. 508-292-7780 Owner's Address Same as Above^^^ Is this permit in conjunction with a building permit? Yes ® No ❑ (Check Appropriate Box) Purpose of Building Residential Utility Authorization No. Existing Service 100 Amps 120 /240 Volts Overhead 7 Undgrd❑ No.of Meters I New Service Amps / Volts Overhead Undgrd n No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of an interconnected Roof Mounted PV system 18 Panels,6.570 KwDC. No Battery Storage Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil: P Sus . Fans Tf Total(Paddle) Tr Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA Above In- No.of Emergency Lighting No.of Luminaires Swimming Pool ,rnd. 1-1I rnd. ❑ Batter Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones of No.of Switches No.of Gas Burners No. InitiatinnggDeteon and n Devices Total No.of Ranges No.of Air Cond. Tons No.of Alerting Devices No.of Waste Dis osers Heat Pump I Number I i l Tons I KW No.of Self-Contained P Totals: Detection/Alerting Devices No.of Dishwashers Space/Area HeatingKW Local❑ Municipal ❑ Other P Connection No.of Dryers Heating Appliances K's Security Systems:* �7 No.of Devices or Equivalent No.of Water No.of No.of Data Wiring: Heaters KW Signs Ballasts No.of Devices or Equivalent No.H dromassa a Bathtubs No.of Motors Total HP Telecommunications Wiring: Y g No.of Devices or Equivalent OTHER:Roof Mounted Solar Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: $8969.00 (When required by municipal policy.) Work to Start:ASAP Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on t s application is true and complete. FIRM NAME: Sunrun Installation Services LIC.NO.:4316 Al Licensee: Nathan Ashe Signature LIC.NO.:21136A (If applicable,enter "exempt"in the license number line.) Bus.Tel.No.:978-594-3519 Address: 695 Myles Standish BLVD Taunton MA 02780 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $ SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION •SYSTEM SIZE:6570W DC,6000W AC •ALL WORK SHALL COMPLY WITH MA 9th Ed.CMR 780(2015 IRC/IBC/IEBC), r , SOLAR MODULES •MODULES:(18)LONGI GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE.AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION SERVICE ENTRANCE PV-1.0 COVER SHEET LTD:LR4-6OHPH-365M INSTRUCTIONS. ° ' ° ° PV-2.0 SITE PLAN •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. SE6000H-USSN MP MAIN PANEL ; 0 0 • PV-3.0 LAYOUT •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. PV-4.0 ELECTRICAL SEE DETAIL SNR-DC-00436 Y'-- SNR MOUNT ° •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP SUB-PANEL SNR MOUNT&SKIRT PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER CHIMNEY •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. ATTIC VENT •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER FLUSH ATTIC VENT MODULES,ARE CLASS A FIRE RATED. PVC PIPE VENT •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). . . T-VENT •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). AC AC DISCONNECT(S) SATELLITE DISH •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC •11.43 AMPS MODULE SHORT CIRCUIT CURRENT. DC DISCONNECT(S) FIRE SETBACKS •17.85 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)&690.8(b)]. CB IQ COMBINER BOX • HARDSCAPE •PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE INTERIOR EQUIPMENT —PL— PROPERTY LINE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION L—i SHOWN AS DASHED SCALE NTS A AMPERE sunrun AC ALTERNATING CURRENT AFC! ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION #180120 DC DIRECT CURRENT ' (E) EXISTING TABDSHBLVDTALI�.�r°N.MA02780,u1 ESS ENERGY STORAGE SYSTEM BM ss FAOo EXT EXTERIOR INT INTERIOR CUSTOMER RESIDENCE: MAG MAGNETIC JEAN CHARLES Bans MSP MAIN SERVICE PANEL 22 OLD SAGA DR,YARMOUTH, (N) NEW MA,02664 I NTS NOT TO SCALE i OC ON CENTER TEL.(508)292-7780 „a 1 PRE-FAB PRE-FABRICATED APN:YARM-000111-000009 E, ta2e _ , 1 -,, . - Y:. PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC PROJECT NUMBER: i.^.ataam 223R-022CHAR Ha'...ci RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS TYP TYPICAL DESIGNER: (415)580-6920 ex3 V VOLTS SUNIL KUMAR W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET • REV:A 8/15/2022 PAGE PV-1.0 „..-.2:3 -0- 91 1 ARRAY TRUE MAG PVAREA SITE PLAN•SCALE=3/64"=1'-0" PITCH AZIM AZIM (SOFT) 41 AR-01 35° 158° 172° 353 / Pl Pl Q' / .. \, (E)RESIDENCE / ... . AMP q, � SE 0 PM INV / e' \ < . ,' , , 11 sunrun , . .. • . #180120 ___------- 6.uVLES STANOISH BIVN,TAUNTON.MA 03]Bp-]111 PHONE 0 0 �. CUSTOMER RESIDENCE JEAN CHARLES Q 22 OLD SAGA DR,YARMOUTH, 0O Pv MA,02664 (N)ARRAY AR-01 TEL.(506)292-7780 p( P` APN:YARM-000111-000009 PROJECT NUMBER: 223R-022CHAR DESIGNER: (415)580-6920 ex3 SUNIL KUMAR SHEET SITE PLAN REV.A 8/15/2022 PAGE PV-2.O ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA _ Max OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF Name Type Height Type Span Spacing Detail OC Spacing Overhang OC Spacing Overhang Configuration SNOW LOAD:30 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 9'-5" 16" COMP,SEE DETAIL SNR-DC-00436 - - -0" STAGGERED 140 MPH 3-SEC GUST. S.S.LAG SCREWS: D1-AR-01-SCALE:1/4"=1'-0" 5/16":2.5"MIN EMBEDMENT STRUCTURAL NOTES: AZIM:158° • INSTALLERS SHALL NOTIFY PITCH:35° ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. 6" • IF ARRAY(EXCLUDING SKIRT) 34'-9" i +1' IS WITHIN 12"BOUNDARY REGION OF ANY ROOF PLANE EDGES(EXCEPT VALLEYS), • THEN ATTACHMENTS NEED 2-5 TO BE ADDED AND OVERHANC f-$ ------ �- -- - ----- --._.------f-}------------$-----------$- t ------- ❑ ' REDUCED WITHIN THE 12„ 1 �— l BOUNDARY REGION ONLY AS FOLLOWS: ••ALLOWABLE ATTACHMENT SPACING INDICATED ON • PLANS TO BE REDUCED BY } ❑ ❑ ❑ 1 ❑ • ❑ ❑ ❑ ❑ 50% : ••ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 10'-3" 1/5TH OF ALLOWABLE • ATTACHMENT 5'-4"TYP - INDICATED ON PLANS SPACING ❑ ❑ ❑ o o ❑ • ❑ Q Q 0 0, 0 U ❑l sunrun 2,-6„ #180120 STRUCT ; e°s MYLESsTANDI5HBLVD.TAUNTON MA 027SO-7321 0 PHONE r�Gos OF Mqy,� FAx aeo p O,y �4 VINCENT -if, CUSTOMER RESIDENCE g MWUMVANEZA N JEAN CHARLES CIVIL 22 OLD SAGA DR,YARMOUTH, ,���' 2 MA,02664 l'O64E10'\� TEL.(508)292-7780 APN:YARM-000111-000009 PROJECT NUMBER: 223R-022CHAR DESIGNER: (415)580-6920 ex3 SUNIL KUMAR SHEET LAYOUT REV:A 8/15/2022 SEE SITE PLAN FOR NORTH ARROW. PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE METER#: < O EVERSOURCE 2376083 UTILITY NOTE:TOTAL PV BACKFEED=31A GRID EXISTING 125A MAIN USED FOR INTERCONNECTION 1 DISCONNECT WITH CALCULATIONS r 1 100A MAIN ENCLOSURE i LOAD SIDE TAP LOCKABLE BLADE SOLAREDGETECHNOLOGIES: TYPE (N)MA SMART FUSED AC UTILITY SE6000H-USSN WITH DISCONNECT REVENUE REVENUE GRADE METERING (1 EXISTING 100A METER 6000 WATT INVERTER JUNCTION BOX PV MODULES OR EQUIVALENT • MAIN BREAKER 31 3' 3? ;2` 1 LONGI GREEN ENERGY TECHNOLOGY a` // CO LTD:LR4-6OHPH-365M ES 1 •• `� O - ^' • �- ��' i / OPTIMIZERS WIRED IN: EXISTING 125A 35A FUSES I I (1)SERIES OF(9)OPTIMIZERS MAIN PANEL SQUARED 240V METER SOCKET LOAD RATED DC DISCONNECT ' (1)SERIES OF(9)OPTIMIZERS \ D222NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN -SOLAREDGE POWER OPTIMIZERS FACILITY 3R,60A UTILITY SIDE OF CIRCUIT COMPLIANT P401 LOADS I 120/24OVAC CONNECTS TO TOP LUGS- +LflO1IN0 (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 $u n ru n 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 6.MYLES STANDISH BLVD,TAUNTON.MA,02760-7.1 PHONE FAX 0 CUSTOMER RESIDENCE: JEAN CHARLES 22 OLD SAGA DR.YARMOUTH, MA,02664 MODULE CHARACTERISTICS P401 OPTIMIZER CHARACTERISTICS: TEL.(508)292-7780 LONG!GREEN ENERGY MIN INPUT VOLTAGE: B VDC APN:YARM-000111-000009 TECHNOLOGY CO LTD: MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: LR4.60HPH-365M: 365 W MAX INPUT ISC: 11.75 ADC OPEN CIRCUIT VOLTAGE: 40.7 V MAX OUTPUT CURRENT: 15 ADC 223R-022CHAR MAX POWER VOLTAGE: 34.2 V SHORT CIRCUIT CURRENT: 11.43 A DESIGNER: (415)580-6920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 SUNIL KUMAR SYSTEM SIZE'. 6570 W - SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 9 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V SYSTEM OPERATING CURRENT: 17.29 A REV:A 8/15/2022 - SYSTEM SHORT CIRCUIT CURRENT: 30 A PAGE PV-4.0 A INVERTER 1 NOTES AND SPECIFICATIONS. •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR ELECTRICAL SHOCK HAZARD IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS,COLORS AND SYMBOLS. TERMINALS ON LINE AND LOAD •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2020:690.53 INVOLVED. LABEL LOCATION •SIGNS AND LABELS SHALL COMPLY VMTH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2020:690.13(B) WARNING: PHOTOVOE TALC POWER SOURCE LABEL LOCATION. DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. AND PV SOLAR ELECTRIC PER CODE(S).NEC 2020:690.31(D)(2),IFC 2012' SYSTEM 605.11.1.4 LABEL LOCATION: cALITIoN • UTILITY SERVICE METER AND MAIN SERVICE PANEL. ■ PER CODE(S):NEC 2626:705.12(C) _ MULTIPLE SOURCES OF POWER POWER SOURCE OUTPUT CONNECTION °ilx` .. �` �✓`� .. DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: INSTALLED WITHIN 3'OF RAPID SHUT DOWN LABEL LOCATION: SWITCH PER CODE(S):NEC 2020.690.56(C)(2),IFC s u n r u n NA TO BREAKER AND ESS 2012'605.11.1,IFC 2018:1204.5.3 OCPD(I OCPD(IF APPLICABLE). PER CODE(S):NEC 2020 , _. _. 4 705.12(6)(3)(2) ., : 1 #180120 St LAR PV SYSTEM EQt IP►PED SS.ANas a o.A MoN Mq 02760.7.1PHOTOVOLTAIC SYSTEM ril FINONe0 COMBINER PANEL WITH S N `AX0 DO NOT ADD LOADS CUSTOMER RESIDENCE: JEAN CHARLES LABEL LOCATION: MAIN PANEL 22 OLD SAGA DR,YARMOUTH, PHOTOVOLTAIC AC COMBINER(IF r, MA,02664 APPLICABLE). PER CODE(S):NEC 2020:705.12(D)(2)(3)(c) 3 TURN RAPID SHUTDOWN SWITCH TO THE"OFF" SOLAR PANELS ON ROOF TEL.(508)292-7780 POSITION TO SHUT DOWN INVERTER /EXT SERVICE ENTRANCE APN:YARM-000111-000009 PV SYSTEM DISCONNECT PVSYSTEMANDREDUCE ` PROJECT NUMBER MAXIMUM AC OPERATING CURRENT.25.00 AMPS SHOCK HAZARD IN THE ARRAY. iriiii PV PRODUCTION METER FUSED AC DISCONNECT 223R-022CHAR NOMINAL OPERATING AC VOLTAGE: 240 VAC DESIGNER: (415)580E920 ex3 LABEL LOCATION: 22 OLD SAGA DR, YARMOUTH, MA, 02664 SUNIL KUMAR AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. SHEET PER CODE(S):NEC 2020:690.54 LABEL LOCATION: PER CODE(S):NEC 2020:705.10,710.10 SIGNAGE ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV:A 8/15/2022 PER CODE(S):NEC 2020 690.56(C) PAGE PV-5.0