Loading...
HomeMy WebLinkAboutBLDE-23-000919 SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION •SYSTEM SIZE:3285W DC,3800W AC •ALL WORK SHALL COMPLY WITH MA 9th Ed.CMR 780(2015 IRC/IBC/IEBC), rem SOLAR MODULES PV-1.0 COVER SHEET •MODULES:(9)LONGI GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION SERVICE ENTRANCE LTD:LR4.60HPH-365M INSTRUCTIONS. IWI ° I ° - ° PV-2.0 SITE PLAN •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. SE3800H-USMN MP MAIN PANEL ' ---E1 PV-3.0 LAYOUT •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. qq PV-4.0 ELECTRICAL SEE DETAIL SNR-DC-00436 1''- SNR MOUNT 0•PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SUB-PANEL SNR MOUNT&SKIRT PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER CHIMNEY •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. ATTIC VENT •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER FLUSH ATTIC VENT MODULES,ARE CLASS A FIRE RATED. PVC PIPE VENT •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). .. T-VENT •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). O AC DISCONNECT(S) SATELLITE DISH •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC O •11.43 AMPS MODULE SHORT CIRCUIT CURRENT. DC DISCONNECT(S) FIRE SETBACKS •17.85 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)&690.8(b)]. CB IQ COMBINER BOX HARDSCAPE •PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE INTERIOR EQUIPMENT —PL— PROPERTY LINE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION L-I SHOWN AS DASHED SCALE:NTS A AMPERE s u n r u n AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION #180120 DC DIRECT CURRENT (E) EXISTING 695 MYLES STANDISH BLVD,TAUNTON,MA,02760-26» ESS ENERGY STORAGE SYSTEM PHONE 0 FAX EXT EXTERIOR --`-:{��,T• '_-' - _ ,..;,:.- INT INTERIOR CUSTOMER RESIDENCE MAG MAGNETIC KELLY LUNDQUIST 0) MSP MAIN SERVICE PANEL 23 COOLIDGE RD,YARMOUTH, �� (N) NEW MA,02673 NTS NOT TO SCALE 23 COOl dUe Rd OC ON CENTER TEL.(508)221.4482 ip PRE-FAB PRE-FABRICATED APN:YARM-000063-000018 VVPS[Yf'Tl( tlll?, [: PSF POUNDS PER SQUARE FOOT PROJECT NUMBER: PV PHOTOVOLTAIC 223R-023LUND RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS TYP TYPICAL DESIGNER: (415)580-6920 ex3 V VOLTS SOHAN SINGH W WATTS _ SHEET REV NAME DATE COMMENTS COVER SHEET REV:A 8/17/2022 PAGE PV-1.0 U) Q— 23 ©� 4 ( 9 ARRAY TRUE MAG PVAREA SITE PLAN-SCALE=1/16"=1'-0" PITCH AZIM AZIM (SQFT) ------ PL ---7 AR-01 24' 87" 101' 176.5 PL -- PL - PL - \------ 7.,_ \ .1' 7 \ (N)ARRAY AR-01 7 7- (E)RESIDENCE ._ ...I S u n ru n #180120 r 665 uVLE55TANDISH BLvD.TAUMON MA 0]760-]]]1 , \t � - - PHONED , \ W Enx o CUSTOMER RESIDENCE: o KELLY LUNDQUIST - 0 23 COOLIDGE RD,YARMOUTH, 7 0 MA,02673 \ i TEL.(508)221-4462 APN:YARM-000063-000018 • TC� PROJECT NUMBER: MP 223R-023LUND INV SE IAC I PM DESIGNER: (415)580-6920 ex3 -- PL SOHAN SINGH - PL SHEET -� PL SITE PLAN L______ PL PL -- REV:A 8/17/2022 PAGE PV-2.O ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:30 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2X8 RAFTERS 10'-9" 16" COMP,SEE DETAIL SNR-DC-00436 5'-4" 2'-1" 4'-0" 1'-10" STAGGERED 140 MPH 3-SEC GUST. S.S.LAG SCREWS: D1-AR-01-SCALE:1/4"=1'-0" 5116":2.5"MIN EMBEDMENT ° STRUCTURAL NOTES: A21M:87 PITCH: • INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. • IF ARRAY(EXCLUDING SKIRT) IS WITHIN 12"BOUNDARY REGION OF ANY ROOF PLANE EDGES(EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS FOLLOWS: 16'-5„ _ _...17'-4, _ ' 1'-9" ••ALLOWABLE ATTACHMENT _ SPACING INDICATED ON PLANS TO BE REDUCED BY • P-8' 50% ....El. ..._.. ....._.. ...___._ __-- .--.1 ......-- --_H...-- _. ••ALLOWABLE OVERHANG INDICATED ON PLANS TO BE pp 1/5TH OF ALLOWABLE ATTACHMENT SPACING 1 • INDICATED ON PLANS • 10' 3„ sunrun .• . . 5,-4„TYP • ' #180120 6 • • 6.MYLES STANDISH BLVD,TAUNTON,MA.02760 7331 //�� /, \/YP\I PHONE 0 FAX 0 1,-6„ CUSTOMER RESIDENCE: KELLY LUNDQUIST 23 COOLIDGE RD,YARMOUTH, MA,02673 STRUCT ONL tH OF TEL.(508)221-4462 �Y� 'r4py APN:YARM-000063-000018 4' VINCENT o.f„ PROJECT NUMBER: o MWUMVANEZA m 223R-023LUND CIVIL � .�pE o . A4.y DESIGNER: (415)580-6920 ex3 9:: E ONAlE10. SOHAN SINGH SHEET LAYOUT REV:A 8/17/2022 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE METER#: < O EVERSOURCE 1936772 UTILITY GRID I SUPPLY SIDE TAP NOTE:TOTAL PV BACKFEED=20A USED FOR INTERCONNECTION CALCULATIONS (N)LOCKABLE SOLAREDGE TECHNOLOGIES: EXISTING 100A BLADE TYPE (N)MA SMART MAIN BREAKER FUSED AC (N)LOCKABLE UTILITY SE3800H-USMN WITH DISCONNECT BLADE TYPE REVENUE REVENUE GRADE METERING I ; . AC DISCONNECT 3 METER a 3800 WATT INVERTER JUNCTION BOX PV MODULES OR EQUIVALENT 2 1 1 LONGI GREEN ENERGY TECHNOLOGY EXISTING / ��_ 125A MAIN /J.' �� �_ H /// CO LTD:LR4bOHPH-365Mo.o. o� o O Q (9)MODULES �� PANEL OPTIMIZERS WIRED IN: FACILITY 20A FUSES - I 1 I (1)SERIES OF(9)OPTIMIZERS LOADS �cRo= L SQUARED SQUARED 240V METER SOCKET LOAD RATED DC DISCONNECT D222NRB DU221RB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS 3R,60A 3R,30A,2P UTILITY SIDE OF CIRCUIT COMPLIANT P401 120/24OVAC 120/24OVAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) 1 CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 $u n ru n 3 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 695 MYLES STAN:ASH BIND,TAUNTON,MA,02700-7331 aX0E9 E CUSTOMER RESIDENCE: KELLY LUNDQUIST 23 COOLIDGE RD,YARMOUTH, MA,02673 MODULE CHARACTERISTICS TEL.(508)221-4462 LONGI GREEN ENERGY P401 OPTIMIZER CHARACTERISTICS: TECHNOLOGY LTD: MIN INPUT VOLTAGE: 8 VDC APN:YARM-000063-000018 TECHNOLOGY COC 365 W MAX INPUT VOLTAGE 60 VDC PROJECT NUMBER: LOPEN CIRCUIT VOLTAGE: 40.7 V MAX INPUT ISC: 11.75 ADC 223R-023LUND MAX POWER VOLTAGE: 34.2 V MAX OUTPUT CURRENT: 15 ADC DESIGNER: (415)580-6920 ex3 SHORT CIRCUIT CURRENT: 11.43 A SOHAN SINGH SYSTEM CHARACTERISTICS-INVERTER 1 SYSTEM SIZE: 3285 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE 9 V ELECTRICAL SYSTEM OPERATING VOLTAGE 380 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:A 8/17/2022 SYSTEM OPERATING CURRENT: 8.64 A SYSTEM SHORT CIRCUIT CURRENT: 15 A PAGE PV-4.0 Ak- INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT IF REQUESTED).UNLESS BY STHE LOCALPECIFIC NSSTRUCTIONS HJ. ARE REQUIRED BY SECTION 690,OR MAXIMUM SYSTEM VOLTAGE: 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS. SIDES MAY BE ENERGIZED IN •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2020:690.53 INVOLVED. LABEL LOCATION' •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. ACCOMBINER INVERTER(S), PANELNC DISCONNECT(S),APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. AC COMBINER (IF APPLICABLE). PER CODE(S).NEC 2020:690.13(B) WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS. ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020:690.31(0)(2),IFC 2012: SYSTEM 605.11.1.4 LABEL LOCATION: UTILITY SERVICE METER AND MAIN CAUTION . SERVICE PANEL. PER CODE(S):NEC 2020:705.12(C) ,,^^��� MULTIPLE SOURCES OF POWER `'iY ti�l ����lk({?lA 54-°'I4/PTvf POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM DO NOT RELOCATE THIS SOLAR PANELS ON ROOF IL/ OVERCURRENT DEVICE LABEL LOCATION: INSTALLED WITHIN 2 SHUT DOWN s u n ru n LABEL LOCATION: SWITCH PER CODE(S): NEC 200 20:890.58(C)(2),IFC ADJACENT TO PV BREAKER AND ESS 2012:605.11.1,IFC 2018:1204.5.3 OCPD(IF APPLICABLE). PER CODE(S):NEC 2020: , a„ 705.12(B)(3)(2) A SOLAR PV SYSTEM EQUIPPED #180120 6.KYLES STAN..VD TAUNTON MA.027e0-7.1 PHOTOVOLTAIC SYSTEM 'WITH RAPIDSHUTDOWN. F AX0 COMBINER PANEL DO NOT ADD LOADS MAIN PANEL(INT) CUSTOMER RESIDENCE LABEL LOCATION: FUSED AC KELLY LUNDQUIST PHOTOVOLTAIC AC COMBINER(IF23 COOLIDGE RD,YARMOUTH, DISCONNECT MA,02673 APPLICABLE). 3" TURN RAPID SHUTDOWN PER CODE(S):NEC 2020:705.12(D)(2)(3)(c) SWITCH TO THE"OFF' MA.8.1.11110 TEL.(508)221-4462 POS DOWN INVERTER (EXT)J 1 APN:YARM-000063-000018 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE PROJECT NUMBER: MAXIMUM AC OPERATING CURRENT'15.83 AMPS SHOCK HAZARD IN THE SERVICE ENTRANCE PRODUCTION METER 223R-023LUND Ell I NOMINAL OPERATING AC VOLTAGE: 240 VAC ARRAY. UNFUSED AC DISCONNECT DESIGNER: (415)580-0920 ex3 LABEL LOCATION: 23 COOLIDGE RD, YARMOUTH, MA, 02673 SOHAN SINGH AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. LABEL LOCATION: SHEET SIGNAGE PER CODE(S):NEC 2020:690.54 ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2020:705.10,710.10 DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV'A 8/17/2022 PER CODE(S):NEC 2020:690.56(C) PAGE PV-5.0