HomeMy WebLinkAboutBLDE-23-000892 or r:. Commonwealth of Official Use Only t) Massachusetts Permit No. BLDE-23-000892 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:8/18/2022 City or Town of YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 55 CAPT NICKERSON RD Owner or Tenant WILLIAM READE Telephone No. Owner's Address 55 CAPT NICKERSON RD, SOUTH YARMOUTH, MA 02664 Is this permit in conjunction with a building permit? Yes ❑ No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system(19 Panels 6.935 KW) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiatine Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons _ KW No.of Self-Contained Totals: Detection/Alertine Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Siens No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 '� Commonwealth o/KiJachuJetb Official Use Only _` - > Permit No. t 23 C !� 2epartment of Sire Services Occupancy and Fee Checked `e BOARD OF FIRE PREVENTION REGULATIONS / [Rev. 107 ] (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 08/16/2022 City or Town of: Yarmouth To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number)55 Captain Nickerson Rd, Owner or Tenant William Reade Telephone No. 508-362-1230 Owner's Address Same as Above"A" Is this permit in conjunction with a building permit? Yes V No ❑ (Check Appropriate Box) Purpose of Building Residential Utility Authorization No. Existing Service 225 Amps 120 /240 Volts Overhead ❑ Undgrd® No.of Meters 1 New Service Amps / Volts Overhead❑ Undgrd ❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of an interconnected Roof Mounted PV system 19 Panels,6.935 KwDC. No Battery Storage Completion of the followin&table may be waived by the Inspector of Wires. otal No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans Tf T Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ ivo.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones of No.of Switches No.of Gas Burners No. Initiatinnggon Dete and In Devices Totallo.of Ranges No.of Air Cond. Tons No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained p Totals: Detection/Alerting Devices No.of Dishwashers Space/Area HeatingKW Local❑ Municipal ❑ Other P Connection No.of Dryers Heating Appliances KW Sec Systems:' t Y art y No.of Devices or Equivalent No.of Water KW No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.H dromassa a Bathtubs No.of Motors Total HP Telecommunications NofDeieor Equivalent g No.of Devices Equivalent OTHER:Roof Mounted Solar Attach additional detail if desired,or as required by the Inspector of Wires. I Estimated Value of Electrical Work: $9467.00 (When required by municipal policy.) Work to Start:ASAP Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on t is application is true and complete. FIRM NAME: Sunrun Installation Services LIC.NO.:4316 Al Licensee: Nathan Ashe Signature LIC.NO.:21136A (If applicable,enter "exempt"in the license number line.) Bus.Tel.No.:978-594-3519 Address: 695 Myles Standish BLVD Taunton MA 02780 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner El owner's agent. Owner/Agent PERMIT FEE: $ Signature Telephone No. SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION •SYSTEM SIZE:6935W DC,6000W AC •ALL WORK SHALL COMPLY WITH MA 9th Ed.CMR 780(2015 IRC/IBC/IEBC), r SOLAR MODULES PV-1.0 COVER SHEET •MODULES:(19)LONGI GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE,AND ALL MANUFACTURERS LISTINGS AND INSTALLATION SERVICE ENTRANCE LTD:LR4-60HPH-365M INSTRUCTIONS. .4 ° 1 ° 0 . PV-2.0 SITE PLAN •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. SE6000H-USSN MP MAIN PANEL ; a PV-3.0 LAYOUT •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. • PV-4.0 ELECTRICAL SEE DETAIL SNR-DC-00436 - SNR MOUNT •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP SUB-PANEL SNR MOUNT&SKIRT PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. IO PV LOAD CENTER CHIMNEY •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. ATTIC VENT •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER FLUSH ATTIC VENT MODULES,ARE CLASS A FIRE RATED. PVC PIPE VENT •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). T-VENT •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). LAC I AC DISCONNECT(S) SATELLITE DISH •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC n DC DISCONNECT(S) FIRE SETBACKS •11.43 AMPS MODULE SHORT CIRCUIT CURRENT. •17.85 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)&690.8(b)]. CB IQ COMBINER BOX • HARDSCAPE •PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE INTERIOR EQUIPMENT -PL- PROPERTY LINE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION L J SHOWN AS DASHED SCALE NTS A AMPERE s u n r u n AC ALTERNATING CURRENT AFC! ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION #180120 DC DIRECT CURRENT Yarmouth (E) EXISTING e95MYLess TANDISHBLVD,TAUNTON,MA,0n80-7331 PHONE 0 ` ESS ENERGY STORAGE SYSTEM FAX EXT EXTERIOR _ - INT INTERIOR CUSTOMER RESIDENCE'. MAG MAGNETIC WILLIAM READE ---- - MSP MAIN SERVICE PANEL 55 CAPTAIN NICKERSON RD, (N) NEW YARMOUTH,MA,02664 55 Captain Nickerson NTS NOT TO SCALE Rd SoutI.YaltloOuth, OC ON CENTER TEL.(508)362-1230 PRE-FAB PRE-FABRICATED APN:YARM-000078-000090 �^, PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC PROJECT NUMBER: _ RSD RAPID SHUTDOWN DEVICE 223R-055READ •=='.I7.•T, TL TRANSFORMERLESS TYP TYPICAL DESIGNER: (415)580-6920 ex3 Mt :euunm • - V VOLTS MDALAM Nest Dennis W WATTS SHEET - 0 �Bedi:n REV NAME DATE COMMENTS COVER SHEET REV:Al 8/14/2022 PAGE PV-1.0 L �2 --caw 89 z ARRAY TRUE MAG PV AREA SITE PLAN DETAIL-SCALE=1/16"=1'-0" PITCH AZIM AZIM (SOFT) /-�� Pt. AR-01 30° 218° 232° 156.9 WI, AR-02 30° 218° 232° 137.3 AR-03 30° 218° 232° 78.4 4 CqA �/C (E)RESIDENCE >c,Qs v Ol (N)ARRAY AR-01 ,Qo / .' 'i, AMP . ./ N. .. < '...........'7 AC 4' INV PM \,,s., . d' 4iiier sunrun Z.------\_ 4- #180120 (N)ARRAY AR-02 885 MYLES STANDISH BLVD.TAUNTON MA,02700,31 PHONE 0 ry (N)ARRAY AR-03 Ax0 CUSTOMER RESIDENCE: WILLIAM READE �, 55 CAPTAIN NICKERSON RD, \ YARMOUTH,MA,02664 At TEL.(508)362-1230 APN:YARM-000078-000090 PROJECT NUMBER: Pc 223R-055READ \ a DESIGNER: (415)580-6920 ex3 Pc MD ALAM SHEET ''''''''.....''''-'.....'-------.- Pt „......j SITE PLAN REV:Al 8/14/2022 PAGE PV-2.O ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA _ Max OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF Name Type Height Type Span Spacing Detail OC Spacing Overhang OC Spacing Overhang Configuration SNOW LOAD:30 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2X6 PRE-FABRICATED TRUSSES 6'-11" 24" COMP,SEE DETAIL SNR-DC-00436 6'-0" 2'-4" 4'-0" 2'-0" STAGGERED 140 MPH 3-SEC GUST. _ S.S.LAG SCREWS: AR-02 COMP SHINGLE-RLU 1-Story 2X6 PRE-FABRICATED TRUSSES 6'-11" 24" RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE 6'-0" 2'-4" 4'-0" 2'-0" STAGGERED 5/16":2.5"MIN EMBEDMENT DETAIL SNR-DC-00436 STRUCTURAL NOTES: RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE • INSTALLERS SHALL NOTIFY AR-03 COMP SHINGLE-RLU 1-Story 2X6 PRE-FABRICATED TRUSSES 6'-11" 24" DETAIL SNR-DC-00436 6'-0" 2'-4" 4'-0" 2'-0" STAGGERED ENGINEER OF ANY POTENTIAL — STRUCTURAL ISSUES D1-AR-01-SCALE:1/8"=1'-0" OBSERVED PRIOR TO AZIM:218° PROCEEDING W/ PITCH:30° INSTALLATION. 21'-5" - - - • IF ARRAY(EXCLUDING SKIRT) IS WITHIN 12"BOUNDARY 1'-11" REGION OF ANY ROOF PLANE -- _-....-_._..._..._.. ......{a- — EDGES(EXCEPT VALLEYS), THEN ATTACHMENTS NEED • TO BE ADDED AND OVERHANC Mil • REDUCED WITHIN THE 12" • BOUNDARY REGION ONLY AS FOLLOWS: 13-10" - , ••ALLOWABLE ATTACHMENT SPACING INDICATED ON - - - PLANS TO BE REDUCED BY • ' I 50% • ••ALLOWABLE OVERHANG tu__ u._ 1 • I INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING ;i 11'-7" 20'-3". f INDICATED ON PLANS D2-AR-02•SCALE:1/8"=1'-0" D3-AR-03-SCALE:1/8"=1'-0" s u n r u n AZIM:218° AZIM:218° PITCH:30° PITCH:30° STRUCT ONL 1HOFMgy, d4 �O '�� VINCENT yr'm #180120 6'-11" - 17'-5" - -, , •';.. 11'-7' ,. - 11'-6"._ MWUMVANEZA N CIVIL 6.MVEIS STANDISH 9wD,TAUNTON.MA,0ne0 nn aHo E0 .. 2_2 2 I 4 N�/ 2 FAX 0 .$ $----- �_..__ _.___.�_-� ? -� : ''' �G`���0 CUSTOMER RESIDENCE: • ONALEN WILLIAM READE _ 0 0. 6'-10" ❑ o ❑ 55 CAPTAIN NICKERSON RD, i- 6'TYP , 10-4, YARMOUTH,MA,02664 L..n..__._.----L--a__ TE- P ' L 2" ///�\\ _ a _._.a.__ 12-9 • APN:VARM(508)36-000078-000090-1230 ' 6 N . d 6-2 PROJECT NUMBER: 223R-055READ \/ 5=9" DESIGNER: (415)580-6920 ex3 MD ALAM • • 12'-9" 11'-7" SHEET LAYOUT REV:Al 8/14/2022 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE O METER#: < EVERSOURCE 2376790 NOTE:TOTAL PV BACKFEED=31A UTILITY USED FOR INTERCONNECTION CALCULATIONS GRID I EXISTING / 225A MAIN l BREAKER I EXISTING (N)MA SMART SOLAREDGE TECHNOLOGIES: / y 225A (N)LOCKABLE UTILITY SE6000H-USSN WITH < �� MAIN BLADE TYPE REVENUE REVENUE GRADE METERING FACILITY — '— PANEL AC DISCONNECT METER 6000 WATT INVERTER JUNCTION BOX PV MODULES LOADS 3 •3 3 _ �/• -2 OR EQUIVALENT ,1 ` LONGI GREEN ENERGY TECHNOLOGY // CO LTD.LR4-0OHPH-365M o O �/ (19)MODULES OPTIMIZERS VIRED IN: ( s I (1)SERIES OF(10)OPTIMIZERS (N)35A �o��No SQUARED 240V METER SOCKET LOAD RATED DC DISCONNECT (1)SERIES OF(9)OPTIMIZERS PV BREAKER AT DU222RB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN L SOLAREDGE POWER OPTIMIZERS OPPOSITE END 3R,60A,2P UTILITY SIDE OF CIRCUIT COMPLIANT P401 OF BUSBAR 120/240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER sun ru n 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 88S MYLES STANDISH 9LVD,TAUNlON,MA,03780-7331 PHONE Far o CUSTOMER RESIDENCE: WILLIAM READE 55 CAPTAIN NICKERSON RD, YARMOUTH,MA,02664 MODULE CHARACTERISTICS LONGI GREEN ENERGY P401 OPTIMIZER CHARACTERISTICS: TEL.(508)362-1230 TECHNOLOGY CO LTD: MIN INPUT VOLTAGE: 8 VDC APN:YARM-000078-000090 LR4-6OHPH-365M: 365 W MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: OPEN CIRCUIT VOLTAGE: 40.7 V MAX INPUT ISC: 11.75 ADC 223R-055READ MAX POWER VOLTAGE: 34.2 V MAX OUTPUT CURRENT: 15 ADC SHORT CIRCUIT CURRENT: 11.43 A DESIGNER: (415)580-6920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 MD ALAM SYSTEM SIZE: 6935 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 10 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:Al 8/14/2022 SYSTEM OPERATING CURRENT: 18.25 A SYSTEM SHORT CIRCUIT CURRENT: 30 A PAGE PV-4.0 INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR ELECTRICAL SHOCK HAZARD IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE. 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS,COLORS AND SYMBOLS. TERMINALS ON LINE AND LOAD •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABIUTY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2020:690.53 INVOLVED. LABEL LOCATION •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. INVERTER(S),AC/DC DISCONNECT(S), •DO NOT COVER EXISTING MANUFACTURER LABELS. AC COMBINER PANEL(IF APPLICABLE). PER CODE(S):NEC 2020:690.13(B) WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS. ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020:690.31(0)(2),IFC 2012: SYSTEM 605.11.1.4 cAuTioN LABEL LOCATION: - • UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S):NEC 2929 765.12(D) • MULTIPLE SOURCES OF POWER • RAPID SHUTDOWN SWITCH POWER1URCE OUTPUT CONNECTION' �' � � �� FOR SOLAR PV SYSTEM -- DO NOT RELOCATE THIS /`ems, OVERCURRENT DEVICE LABEL LOCATION: �����`'" INSTALLED 3'OF RAPID SHUT DOWN SOLAR PANELS III LABEL LOCATION: SWITCH PERR CODE(S):NEC 2020:690.56(C)(2),IFC ON ROOF _ s u n r u n ADJACENT TO PV BREAKER AND ESS 2012 605.11.1,IFC 2018:1204.5.3 OCPD(IF APPLICABLE). Elgjfil6 I 1 PER CODE(S):NEC 2020: 4" L_l—I 705.12(B>(3)(2) MAIN PANEL AND PV ' SOLAR PV SYSTEM EQUIPPED BREAKER DISCONNECT #/80120 PHOTOVOLTAICIRPSYSTEM WITH RAPID SHUTDOWN • SERVICE ENTRANCE F.0E�pss TAND SN BMW,TAUNTON.MA,027B0.7d.11 • COMBINER PANEL DO NOT ADD LOADS UNFUSED AC DISCONNECT INVERTER (EXT) CUSTOMER RESIDENCE: WILLIAM READE LABEL LOCATION: PV PRODUCTION METER 55 CAPTAIN NICKERSON RD, PHOTOVOLTAIC AC COMBINER(IF YARMOUTH,MA,02664 APPLICABLE). PER CODE(S):NEC 2020:705.12(D)(2)(3)(c) 3" TURN RAPID SHUTDOWN SWITCH TO THE"OFF" e MAIMS TEL.(508)362-1230 POSITION TO SHUT DOWN APN:YARM-000078-000090 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE PROJECT NUMBER: MAXIMUM AC OPERATING CURRENT:25.00 AMPS •- SHOCK HAZARD IN THE ARRAY. II 223R-055READ NOMINAL OPERATING AC VOLTAGE: 240 VAC LABEL LOCATION: 55 CAPTAIN NICKERSON RD, YARMOUTH, MA, 02664 DESIGNER:MDALAI (415)580-6920 ex3 AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. SHEET PER CODE(S):NEC 2020:690.54 LABEL LOCATION: PER CODE(S):NEC 2020:705.10,710.10 SIGNAGE ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV'Al 8/14/2022 PER CODE(S):NEC 2020:690.56(C) PAGE PV-5.0