Loading...
HomeMy WebLinkAboutEngineer PlanASSESSORS MAP: �49>7 _._ .. ''2-o 7 PARCEL* -- C —� REFERENCE: ELL r , " . 2. I j LOCATION MAP TEST L HOLE 1) The installation sha comply with the State Environmental Code Title V an Town o L !® i 1kCry{. Board of Health Regulations. t q 2j Ilhe septic system as proposed on this plan shall not be installed until a licensed town ? SOIL EVALUATOR:��-i ! �� � �, L : � , � 5.. --r- ,� installer receives approval and an installation permit from the applicable fawn. a WITNESS: `j 2L, 1 3) Prior to installation, the installer shall verify the location of utilities, sewer inverts, sewer lines and existing septic components prior to installation. DATE: 4) All gravity sewer piping is to be 4 inch schedule 40 PVC at 1/8" per foot. The first 2 PERCOLATION RATE: 1 1 feet out of the distribution box shall be level. All piping connections to be glued. 5) This septic design plan is not to be utilized for property line determination or for any T.H.#1 ELEV.—CL T.H.#2 ELEV. other purpose other than the proposed septic system installation. 6) All Title V components are to meet Title V specifications. 7) Parking shall be prohibited over Title V components unless components are H2O 1 loaded. {� 8) The existing leaching or cesspools shall be pumped and filled with material per 1 isle V 4 abandonment procedures. Leaching and cesspool(s) and contaminated soils within the proposed SAS shall be removed and replaced with clean sand per Title V tspecifications. j 9) Septic components are to be 10' from a water service line. Sewer lines crossing a II water line shall be sleeved with an appropriately sized schedule 40 PVC with ends 1 ' grouted. The water service line or the septic line can be sleeved with the sleeve being a distance of 10' on both sides of crossing the line. If a garbage grinder exist h fracture, it is to be removed if the septic system is - not deLM signed to accommodate a garbage grinder. 11) The installer is responsible for care of ezca`vatlon- ound all utilities on the property 1 SEPTIC SYSTEM DESIGN CALCULATIONS and protecting the structural integrity of all structures during the installation process of the septic system. /J FLO ESTIMATE: 12) This plan only represents that a septic system can be installed on the property BEDROOMS AT 11 �' GAL/DAY/BDRM AL/DAY meeting Title V requirements. 13) The property owner shall review design criteria to approve the total number of SEPTIC TANK: bedrooms and design flow. installation of the septic system as proposed and receipt GAL/DAY/BDRM X 2 DAYS = GALLONS of payment for the design shall be deemed approval of the design criteria by the j �/ property owner or agent of. USE�.� GALLON SEPTIC TANK L/ �{ / "Z'/ 14) The validity of this plan shall expire with the expiration of the town installation permit (GARBAGE GRINDER IS PROHIBITED) issued for this pian or the validity of this pian shall expire on the expiration of the Certificate of Compliance issued for the installation of the proposed system on this SOIL ABSORPTION -SYSTEM:-'` - plan. - -- SIDEWALL AREA: °+C ( /�1 ✓" y ' + (t ' 7 v�� iY1 oF,y� _ 7 / C✓r (.. �- V y�.o. Lo �"L�1ipBVID BOTTOM AREA. NEpL�' �EP cs g��o. fps SEPTIC SYSTEM SECTION BENCHMARKMX z ' Lel blf TOP OF FOUNDATION ---- I% ELEV. ✓ t 6" STONE BASE (DATUM ASSUMED) - -- -- -------- H2O D -BOX -__.— 6" STONE BASE OR COMPACT€D BASE WATER TEST FOR LEVELNESS I 37 GALLONS SEPTIC TANK 1f HrTE AND SEWAGE PLAN LOCATION: �.. Z v `k Yarmouth Health Department APPROVED PRE Na a Date SCALE:' DATE: Z