Loading...
HomeMy WebLinkAboutEngineer PlanN 50 �\ 48 \ Aa 3 43.4 45.2 A 50----- DoT 16 ` \ 52 AREA = 15480 sf — 1 \ 52--- -ELaN BOOK 2'28 PAGE 25�- AssR ii): M: 135 L: 06 �. 10 \ i 0 vent �\ -50 \ 0\ O \� \ 0 In l48 1° m BS TSF >ti i} 8 M@ SC48 C 48 ° 48. i � � BXIS� SEP COOOG TANK'� I LP l o / '--44 54 52 ) 42 56 48 i 4'6 44. LEGEND SCALE: 1"=20' Yarmouth Health Department Date JUL 2 6 2022 HEALTH DEPT. SURVEY BY: WELLER & ASSOC. YARM LOCUS 14 AUSTRAILIAN AVE LOCUS INFORMATION PLAN REF: 228/003 TITLE REF: 29328/0037 PARCEL ID: M: 136 L: 006 PROPERTY IS WITHIN A ZONE II FLOOD ZONE: NOT IN FLOOD ZONE LOCUS MAP SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 14 AUSTRALIAN AVENUE YARMOUTHPORT, MA PREPARED FOR ALEX PENDLETON/ DYROOTER EXC. LY 25. 2022 STEVEN W� N�y. t\\ OF 1140 - 20-2L MEYER & SONS INC. P.O. Box 981 E. SANDWICH, MA 02537 PH. (508)360-3311 fax (774)413-9468 meyerandsonstitle5@gmail.com PROPOSED CONTOUR r9-81 PROPOSED SPOT GRADE -- gg -- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE —W— EXISTING WATER SERVICE & TEST PIT SCALE: 1"=20' Yarmouth Health Department Date JUL 2 6 2022 HEALTH DEPT. SURVEY BY: WELLER & ASSOC. YARM LOCUS 14 AUSTRAILIAN AVE LOCUS INFORMATION PLAN REF: 228/003 TITLE REF: 29328/0037 PARCEL ID: M: 136 L: 006 PROPERTY IS WITHIN A ZONE II FLOOD ZONE: NOT IN FLOOD ZONE LOCUS MAP SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 14 AUSTRALIAN AVENUE YARMOUTHPORT, MA PREPARED FOR ALEX PENDLETON/ DYROOTER EXC. LY 25. 2022 STEVEN W� N�y. t\\ OF 1140 - 20-2L MEYER & SONS INC. P.O. Box 981 E. SANDWICH, MA 02537 PH. (508)360-3311 fax (774)413-9468 meyerandsonstitle5@gmail.com F.F. ELEV. (Existing) = 56.0 SLAB ELEVATION EL. 48.50 EXISTING OUTLET INV: 46. NOTE:. PLACE MAGNETIC MARKING TAPE OVER ALL COVERS BRING LEACHING COVERS TO W/IN 3" OF FINISH GRADE BRING ALL COVERS TO FINISH GRADE W/METAL RINGS AND COVERS. FINISHED GRADE (48.0-50.0) F.G.EL: 48.50 F.G. EL: 50.00 VENT MAINTAIN 2% MIN SLOPE OVER LEACHING AREA p TEE'S ARE TO BE 4" SCH 401 PVC EXIST. 1,000 Gf GAS BAFFLE TO OUTLET TEE AS TUF-TITS, ZABE NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION 2) D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2) 3) REPLACE EXISTING 1,000 GALLON SEPTIC TANK WITH 1500 GALLON SEPTIC TANK IF FAILED, DAMAGED OR UNDERSIZED. 4) INSTALL INLET &c OUTLET TEES W/ GAS BAFFLE AS REQUIRED SOIL LOGS 1 INV. 46.05 BAFFLE ON SEPTIC TANK INSTALLED ON >NUFACTURED BY OR EQUAL 2" OF 3/8" DOUBLE WASHED STONE OR FILTER FABRIC 4" SCH 40 PVC " S= 1 INV. 44.6 INV. 44.45 PROPOSED DB -3 DISTRIBUTION BOX (H20) SEPTIC SYSTEM PROFILE DATE: JUNE 29,2022 SOIL EVALUATOR: DARREN MEYER, RS, ES 1614 WITNESS: JAY GARDINER, YARM UTH HEALTH Elev. TP -1 Depth 48.00 A 0" LOAMY SAND 10YR 3/2 47.17 10" B LOAMY SAND 1 OYR 5/8 44.6740" C MEDIUM SAND 2.5Y 6/4 "Ali 132" PERC RATE <2 MIN/IN. ("C" HORIi NO GROUNDWATER OBSERVED DEPTH INV. ELEV.= 44.05 4' / 1 3 X 8.5 TOP CONC. ELEV.= 45.05 INV. ELEV.= 44.05 BOTTOM EL.= 42.0 SEPARATION 5.05 FT. OF TESTHOLE EL: 37.00 GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: - 310 CMR 15.405 (1) (8): 1) A 1.95 FT. VARIANCE FROM 310CMR15.221(7) TO ALLOW LEACHING TO BE 4.95 FT (APPRX) BELOW GRADE VS REQ'D 3 FT. (H20/VENT PROVIDED) 3. EDISPOSAL SHALL NFC PRIOR TO INSPECTION AND BY THE BOARD BACKFILLED AND THE DESIGN ENGINEER. 4. ANY CONDMONS ENCOUNTERED DURING CONSTRUCTION DIFFERING ENGW RO BEFO EWCONSTRUCTIO CN HEREON ONTINUES. BE REPORTED TO THE DESIGN 5, ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. R SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 10. EXISTING LEACHING TO BE PUMPED, CRUSHED AND FILLED PER TITLE 5. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY 13. NO PRIVATE WELLS WITHIN 150' OF PROPOSED LEACHING. 14. ALL PIPING TO BE 4" SCH 40 0 1/8"/Fr (UNLESS SPECIFIED) EFFECTIVE LENGTH = 33.5' 3/4" - 1-1/2" DOUBLE WASHED E! BREAKOUT ELEV.= 45.05 3.75' I 5 FT. I 3.75' EFFECTIVE WIDTH = 12.5' SOIL ABSORPTION SYSTEM (SECTION) 500 GALLON H-20 LEACH CHAMBER, DESIGN CRITERIA NUMBER OF BEDROOMS: 4 BEDROOM DESIGN SOIL TEXTURAL CLASS: .CLASS 1 (0.74 GPD/SF) DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 110 G.P.D. X 4 BR = 440 G.P.D. GARBAGE GRINDER: NO (not designed for garbage grinder) SEPTIC TANK: 440 gpd x 200% = 880 gpd, USE EXIST. 1,000 GAL. SEPTIC TANK LEACHING AREA REQUIRED: (440)/0.74 = 594.59 S.F. USE THREE (3) 500 GALLON H-20 PRECAST LEACH CHAMBERS W/ 4' STONE ON ENDS & 3.75' STONE ON SIDES: 33.5' L x 12.5' W x 2'D BOTTOM AREA: 33.5 x.12.5 = 418.75 SF SIDE AREA: (33.5 + 12.5) X 2 X 2 = 184 SF TOTAL SQUARE FEET PROVIDED = 602 vs. 594.59 REQ'D DESIGN FLOW PROVIDED: 0.74(602 S.F.) = 445.48 G.P.D. vs. 440 G.P.D. req'd PROPOSED SEPTIC SYSTEM UPGRADE PLAN 14 AUSTRALIAN AVENUE, YARMOUTHPORT, MA Prepared for: Alex Pendleton/Ready Rooter Exc. Design and Site Plan by: SCALE DRAWN DATE MEYER &SONS, INC. N.T.S. DMM 07/25/22 PO Sox 991 REV DATE CHECKED SHEET NO. EAST SANDWICH, MA 02537 509-362-2922 DMM 2 of 2