Loading...
HomeMy WebLinkAboutEngineer Planr�S ESSEX WAY 10402 103.85 104,86 10473 ---x 87'29'50 E," 50.00', w II -- 3 o) V LOCUS �, — 9�j 10397 CC) LOl ff�. II a �"� N Z ':,� PK SET 103,48 � :! �'_, �' Ma3E 10375 .._.z_,. BDH OCUS MAP CONTOUR --64 - — EXISTING x 60.98 EXISTING SPOT GRADE 102.74 —WEXISTING WATER SVC. - --EXISTING GAS SERVICE V V IS EST PIT -�BENCHMARK GEND `". - ^ 102.36 'J 101.83 I N` a OWNER OF RECORD GRONBERG, GRONBERG, AARK A <AREN T \` N O �o 19 ESSEX WAY m p YARMOUTH FORT, MA 02375 O N CD PLAN REFERN ES: 0 CA O O ' 1) PLAN BK 535 PG 37 M 2) PLOT PLA DATED 8/2379 BY TAYLOR GROUP OF ,♦sq O - SS,yC �+� 100 58 , OROWELC @X'V 89 WILLO STREET Yarmont6 Health De artment T. P YARMOUTH PORT, MA 02375 o PETER �, g McEN APPROVED o� CIVIL "' 0VIL, No. 35109�gmL 1� istFR�o ame Date EXISTING SEPTIC TANK (TO BE REI, 0VED & REPLACED) 199;80. TOP OF TANK, EL=703.88 1NV.(1AN=7 2.80± INV.(OU T) 102.554 S 87'29'50" W 130.00' r o { } 103.07 w%SHED N N s ` 99 56 ^ C-141- tx 1042 } _ v p z t PAVED x102.19 i LOT .. 1 A _ x(102,04 10117 DRIVEWAY `y00.02 22,290± S.F. FUTURE ADDITION `u 128 -x _ 100 61 - x 103.42 0 103,86 /// 103,37 .. WALK + 1031 STONE, �- DRIVEWAY:, P + p 76 100,35 o 104,02` 1 �4^ f S A -f i r�'` //, f, �O ti j 'f r 103.12 X101 6./ 100 71. in 'sir .1 ?,4 f1I/g;.' ` 'r'EXISITING x 1 1 ' I' exr / f \. ..\ ` rNv �pl1�F%?. f'IOUSE�#18),'',. � 1041 TP \V PROP. :! T O F 105.66.±/ i F SEPTIC�/ 10421 O f f > °� /�F 7 \O 1035 `i lO1 J 101.39 10308' ,I 104,70 '�}:, ', 103.46 BM' \� 1 4.78 �- .. l 104 a0 + \ \ 104.54 i lam: i a 104.65 \fR 'GARAGE \` 103.46 x f/f t 1 STONE �` _ f f �r �� FUTURE ADDITION 103.92 10411 x �,t ! f f X 03.83 pf ' �\ x 102.77 EENCE LINE (T �. 166.56' -c 104.87 '�ST1a'OUT 90!JiVDF1RY_ S 88'03'10" E `— EXISTING LEACHING TO BE PARTIALLY TRENCH REMOVED SEE HOT-- II - PROPOSED S.A.S. BENCHMARK 7 LG -6 UNITS SURROUNDED �OR,�oO�� STEP PARTIALLY ABANDONED MAP (D• 133-45 AND WITH 3.5' OF STONE, ALL SIDES Engineering b): SCALE DRAWN JOB. NO. PROPOSED SEPTIC SYSTEM UPGRADE PLAN Engineering Works, Inc. 1"=20' P.T.M. 224-22 g ESSEX WAY YARMOUTH PART MA 12 West Crossfield Road, Forestdole, MA 02644 DATE CHECKED SHEET N0. Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA -2673 (508) 477-5313 6/28/22 P.T.M. 1 Of 2 NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL: 102.2 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. SEPTIC TANK PROPOSED D -BOX PROPOSED S.A.S. INSTALL RISERS & COVERS OVER INLET & INSTALL RISER AND COVER INSTALL RISER & COVER OVER ONE CHAMBER(MIN.) O L TLET AND SET TO 6' OF FINISH GRADE SET TO WITHIN 6" OF FINISH AND SET TO WITHIN 3" OF FINISH GRADE TO SERVE T.O.F.=105.7± GRADE AS AN INSPECTION MANHOLE.: F.G' ESTING 41 F.G. EL=104.41 EXISTING F.G. EL.=104.5± F.G. EL.=104.3± L=17' ;® L= 4' L= 16' s=17 (MIN.) • 4"SCH40 PVC (MIN.) p S=1% MIN. ® S=1% (MIN.) lww4w�_ ..... .'- 4"SCH40 PVC 4"SCH40 PVC 6' " 2° LAYER OF 1/8" ®� ® TO 1/2 DOUBLE 14" 6 12" WASHED STONE INV.=102.3 48" LIQUID INV.=102.10 (OR APPROVED FILTER FABRIC) LEVEL PROPOSED INV.=101.86 3.5' 3' 3.5' 3/4"-1 1 2" / Cris BAFFLE D -BOX INV.=102.03 EFFECTIVE WIDTH = 10' DOUBLE WASHED �m aim AM WE H-10 RATEo INV.=101.70 STONE PROPOSED SEPTIC TANK USE 7 LC -6 LEACHING CHAMBERS IN SERIES WITH EWER OUTLET 3.5' OF DOUBLE WASHED STONE ON ALL SIDES H-10 RATED CONNECT TO NEW AT HOUSE, INV.=1 3.101 VERIFY TOP CONC. ELEV.=102.53 -BREAKOUT CONTRACTOR ®®®O ®®® INV. ELEV.=101.70 t ELEV.=102.2 SHAH VERIFY ALL EXISTING PIPE E2 E3 0 E3 la la INVERTS, PRIOR TC INSTALLATION. BOTTOM ELEV.=100.70 2) D -BOX SHALL BE SET LEVEL AND TRUE TO 3.5' 7 x 6' = 42' 3.5' GRADE ON A MEC ANICALLY COMPACTED SIX 4' OF NATURALLY OCCURRING INCH CRUSHED STONE BASE, AS SPECIFIED IN PERVIOUS MATERIAL EFFECTIVE LENGTH = 49' 310 CMR 15.221( ). 5' (MIN.) ABOVE G.W. 3) INSTALL INLET & CUTLET TEES AS REQUIRED. LEACHING SYSTEM SECTION 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE EST. HIGH GW, EL=95.7 AS MANUFACTURED BY TUF-LTE, ZABEL OR EQUAL. SEPTIC SYSTEM PROFILE GENERAL NOTES: SOIL LOG 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALT AND THE DESIGN ENGINEER. 2. DATE: JUNE 23, 2022 ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS PET SOIL EVALUATOR: ER McENTEE (SE#1542) R: PETER OF THE STATE EN IRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. WITNESS: JAY - HEALTH AGENT 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR Elev. TP Depth TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE 0" DESIGN ENGINEER. 104.2 A 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING LOAMY SAND FROM THOSE SHO N HEREON SHALL BE REPORTED TO THE DESIGN 103.4 10YR 4/2 9" ENGINEER BEFORE CONSTRUCTION CONTINUES. B --5.-ALL -ELEVATIONS BASED ON AN ASSUMED DATUM - - `-- -- _ _ -" --'- -' LOAMY SAND-- - - 10YR 5/8 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR DR OWNER TO NOTIFY THE LOCAL BOARD OF MINOR STRIPOUT MAY BE 101.5 32" HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. REQUIRED TO "C" HORIZON C PERC 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 32"/50" B. THERE ARE NO WELLS WITHIN 150' OF THE PROPOSED S.A.S. MED. SAND 9. ALL AREAS CLEAR D FOR CONSTRUCTION SHALL BE RESTORED AS 10YR 6/4 AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE DIRECTED BY THE APPROVING AUTHORITIES. 95.7 ADJ. G.W. a 102" 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY 95.0 STC. G.W. - 110" THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 94.7 114" 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS STANDING G.W. 110" (EL.=95 INDEX WELL, RDWZONEE ADJUSTMENT= O.T, MAY. 2022 IN THE AREA BEN ATH AND. FOR 5' ON ALL SIDES OF THE S.A.S. AND PERC RATE TE <2 ("C" HORIZON) REPLACE WITH CH AN SAND AS SPECIFIED IN 310 CMR 255(3). .MIN/INN. 12. AREAS REQUIRING. STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND NOT CONSIDERED TO BE A PROPERTY LINE SURVEY. 14. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC SYSTEM COMPON TS NOT SHOWN ON THE PLAN. r--------_ --------- 4 KNOCKOUT DESIGN CRITERIA I zo• ow. awm I I I NUMBER OF BEDRO MS: 4 SOIL TEXTURAL CLASS: CLASS I" r KNocKour a• KNoaourm' DESIGN PERCOLATIO RATE: <2 MIN/IN 4• KNOCKOUT DAILY FLOW: 4 0 GPD --_------ ------ DESIGN FLOW: 4-0 GPD 72• 1 GARBAGE GRINDER: NO -AND NOT PERMITTED WITH THIS DESIGN PLAN VIEW LEACHING AREA REQUIRED: (440 GPD) = 594.6 SF .74 GPD/SF --------------, r- -� ®®® ® ®®® • PROPOSED SEPTIC ANK: 1500 GALLON CAPACITY, H-10 RATED INVE � 2 2 ®®®®®® ® PROPOSED DISTRIBUTION BOX: 1 INLET, 3 OUTLETS, H-10 RATED USE 7 LC -6 LEACHING CHAMBERS IN SERIES WITH SHED STONE ON ALL SIDES r 72" f' D T E VIEW END VIFW 3.5' of DOUBLESID SIDEWALL AREA: (10 + 49') x. 2 x 1' = 118.0 SF WIGGIN LC -6, H-10 LOADING BOTTOM AREA: 10.0' x 49.0' = 490.0 SF LEACHING CHAMBER TOTAL AREA: ........................................................... 608.0 SF DESIGN FLOW PROVI ED: 0.74 GPD/SF(608.0 SF) = 449.9 GPD ".rs Engineering by: SCALE DRAWN I JM NC. PROPOSED SEPTIC SYSTEM UPGRADE PLAN Engineering Works, Inc. N.T.S. P.T.M. 224-22 19 ESSEX WAY YARMOUTH PORT MA 12 West Crossfield Ro d, Forestdole, MA 02644 DATE CHECKED SHEET No. Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA -2673 (508) 477-5313 6/28/22 P.T.M. 2 Of 2