HomeMy WebLinkAboutEngineer PlanSY (NOT TO SCI± ACCESS COVERS TO WITHIN 6" OF FIN. GRADE TOP FOUND. EL. 12.2' , C.o• 11 2.O MINIMUM J�OVER OVER PRC qd1 PRECAST H-10 WATERTEST D'BOX l RMERS (rm.) FOR LEVELNESS 4"OSCH40 PVC \ 2'° PIPES LEVEL 1ST 2' 10.36' 10" 1500 GAL H-20 14- 938' TEE SEPTIC TANK TEE 9.53' ,g,no� GAS BAFFLE 8 96' •.,. . 4' LIQ. LEVEL (ACME OR EQUAL) C 1 n°'0000000 0^0000 000000000000000o0oo0gu00000 6" CRUSHED STONE OR MECHANICAL COMPACTION.: (15.221 (21) 2 C %.SLOPE). ( 1 % (_z sLOPE)MIN. H.2o FOUNDATION- 29' - SEPTIC TANK 40' D' BOX 6' (LONGEST RUN) *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY fes/ PORTION OF SEPTIC SYSTEM p P FLEGEND TING. CONTOUR T. SPOT ELEV. POSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 TEST HOLE 1% SLOPE OF GROUND 31 C71> UTILITY POLE V..FIRE HYDRANT Y NOTE: NOT ALL SYM90L9 MAY APPFAR NI DRAY19i0 TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: _ BRUCE MURPHY, RS, CHO DATE: 4/7/22 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. n 0.. 4 12.0' A A py LS /R R 4/1R9" / / / 12" // / /10YR 4/6 j110 8' 26, 1 // 4/6 C C PERC MS MS 2.5Y 7/3 2.5Y 7/3 aOo apo ELEV. \ 9` 11.0' 0 n / MARK CORNERS OF LEACHING FIELD W/ REBAR SET 4" BELOW INSPECTION PORT GRADE 2% SLOPE FILTER FABRIC 11 0 TOP 9.25' FINISHED GRADE- 4" LOAM & SEED l CLEAN FILL 4" PERFORATED PVC 3' O.C. S=0.005 O' 3/4"-1-1/2" DOUBLE WASHED a .5" STONE LEACHING FIELD 0 LEVEL BOTTOM - _ 40.0 -- LEACHING FACILITY B .J �e a PAVED DRIVEWAY AY a � a ° y� i .83' ((>> GROUNDWATER ADJ. DATA: WELL: MIW 29 ZONE: A ADJUSTMENT: 1.3' (APRIL) 1.92' y�OBS. G.W 126" 1.5' 126' 0.5, NO GROUNDWATER ENCOUNTERED GROUNDWATER ENCOUNTERED AT 109" £L. 1.92 DEG DCE ##22-060 n I INV. A EL. 10.36 IaD b / 60.47 LOT 46 18,488± S.F. o ` !,O a 5' REM VALQOF UNSUITABLE SOIL REQUIRED,\ AROUND PERIMETER OF LEACHING FACILITY, �- DOWN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MED. SAND, TO MEET SPECIFICATIONS OF 310 CMR 15.255(3) 2 Scale: 1 "= 20' 0 10 20 30 40 50 FEET 0 6"DEPTH MIN. -BELOW INV. 5.0' ADJUSTED GROUNDWATER EL. 3.22 SHED NOTES 1; DATUM IS NAVE) 88 2. MUNICIPAL WATER IS EXISTING. 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -2Q 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. CONTRACTOR SHALL BE RESPONSIBLE FOR CA LOTUS ��� CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF SCALE 1"=2000'± WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL ASSESSORS MAP 26 PARCEL 41 BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. LOCUS IS WITHIN FEMA FLOOD ZONE X 12. EXISTING LEACHING FACILITY SHALL BE PUMPED (AREA OF MINIMAL FLOOD HAZARD) AS AND REMOVED OR PUMPED AND FILLED WITH CLEAN SHOWN ON COMMUNITY PANEL #25001C0589J SAND. DATED 7/16/2014 13. OWNER'S ENGINEER TO PERFORM INSPECTION OF FINAL INSTALLATION. MINIMUM 24 HOURS NOTICE REQUIRED. SYSTEM DESIGN. -- GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 4 BEDROOMS ® 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 USE A 1500 GAL. H-20 SEPTIC TANK LEACHING: 440 GPD (.74) = 595 SF REQUIRED 15' X40'=600 SF OK 600 SF X .74 = 444 GPD OK BENCHMARK: USE A 15' X 40' PIPE AND STONE LEACHING FIELD SPK SET =11.7' NAVD88 APPROVED DATE B ARD OF EALTH TITLE 5 SITE PLAN OF o °Fpr 41 PEREGRINE LN. SOUTH YARMOUTH, MA 0 PREPARED FOR PAUL LANDRY IAA OS" !NIELS�cyc °= DANIELA y6m DATE: APRIL 29, 2022 m o CJALA CIVIL "' OJA �A �' No. 46502 off 508-362-4541 Na, 40980 y v o �� I fax 508-362-9880 4' °/srti�� �` downcope.com O SUR V'�QP. FS'S/ONAI r/owa cope espaterinj, int. t' �0 civil engineers land surveyors 2<-I.Z, 939 Main Street ( Rte 6A) DATE DANIEL A. OJALA, P.E., P.L.S. YARMOVTHPORT MA 0260 0 LANDRY.DWG �> ra -e. SON m ow N- a m � D � � ' J o _ m � a tocu Pere rg, Ln , Shot e Or �l oth Nantucket Sound CONTRACTOR SHALL BE RESPONSIBLE FOR CA LOTUS ��� CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF SCALE 1"=2000'± WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL ASSESSORS MAP 26 PARCEL 41 BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. LOCUS IS WITHIN FEMA FLOOD ZONE X 12. EXISTING LEACHING FACILITY SHALL BE PUMPED (AREA OF MINIMAL FLOOD HAZARD) AS AND REMOVED OR PUMPED AND FILLED WITH CLEAN SHOWN ON COMMUNITY PANEL #25001C0589J SAND. DATED 7/16/2014 13. OWNER'S ENGINEER TO PERFORM INSPECTION OF FINAL INSTALLATION. MINIMUM 24 HOURS NOTICE REQUIRED. SYSTEM DESIGN. -- GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 4 BEDROOMS ® 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 USE A 1500 GAL. H-20 SEPTIC TANK LEACHING: 440 GPD (.74) = 595 SF REQUIRED 15' X40'=600 SF OK 600 SF X .74 = 444 GPD OK BENCHMARK: USE A 15' X 40' PIPE AND STONE LEACHING FIELD SPK SET =11.7' NAVD88 APPROVED DATE B ARD OF EALTH TITLE 5 SITE PLAN OF o °Fpr 41 PEREGRINE LN. SOUTH YARMOUTH, MA 0 PREPARED FOR PAUL LANDRY IAA OS" !NIELS�cyc °= DANIELA y6m DATE: APRIL 29, 2022 m o CJALA CIVIL "' OJA �A �' No. 46502 off 508-362-4541 Na, 40980 y v o �� I fax 508-362-9880 4' °/srti�� �` downcope.com O SUR V'�QP. FS'S/ONAI r/owa cope espaterinj, int. t' �0 civil engineers land surveyors 2<-I.Z, 939 Main Street ( Rte 6A) DATE DANIEL A. OJALA, P.E., P.L.S. YARMOVTHPORT MA 0260 0 LANDRY.DWG