Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. "l Lot a..._ Zone of Contribution: In Out / Acreage 15 __ 7/� /�' Commercial: Residential: i„�._ Street: 5 /: e C e r nr e.e &_. Village: Floor Plan: #Bedrooms: 3 Owner: A ro D JA o N`/ J3 0 r,54-7`41 Installer: 13 157a Address: Phone: Phone: Builder: Engineer: D Qv.¢. Ic•,C1&$o Address: Phone: Phone: N/A YES NO 1. Required#of copies received -- _ 2. Date of soils exam and percolation test not older than 2 years -- 3. 4-5 ft of naturally occurring pervious material, above water table � 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5. Water line 10 ft from septic components Var.: 6. Benchmark indicated and shown-NGVD if near wetlands V 7. Septic tank minimum 10 ft from foundation,deck Var.: _ 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9.Leaching minimum 100 ft from wetlands Var.: 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: V 11.Tank/leaching minimum 10 ft from property line Var.: .: i 12. System meets all other setback requirements Var.: 13. Uses adjustment for maximum high groundwater Var.: / '(,)44r i A N c.-e. 1. - 14. Leaching set 4-5 ft above adj.'water or bottom of test hole Var.: ‘../..- 15. -'15. System not in top or subsoil(A,B horizons)or 5' removal 1 .I/ 16. Proposed contours are suitable 17. System meets slope requirements-min. 1/8", 'A"preferred i , 18. System meets breakout requirements PVC liner: Wall: ✓/� 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal V 22. System adequately sized for its intended use 23. Minimum 6"stone or compacted below tank and dbox ' 24. Manhole covers within 6"of grade, pump chamber cover to grade \-- 25. Inspection port on plastic chambers/leach field 26. Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2"line,weep hole,check valve, tee in dbox,pump size 28. Septic tank/pump chamber to be factory waterproofed 29. Vent provided if leaching below 3 feet,under driveway/parking / 30. Buoyancy calculations for tank/pump chamber 31. Engineer to inspect and certify soils: wall: commercial: 1/;••••",„ 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic, groundwater 1 34.Title V Application and permit fee, installer signature v 35. Foundation footing min. 2 feet above adjusted ground water for new house / 36. Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/Label groundwa(/ter`in Assessor's Map V Plan reviewed by: ^�,,�_ C�Vt E- 30-01)- --