HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. "l Lot a..._ Zone of Contribution: In Out / Acreage 15
__ 7/�
/�' Commercial: Residential: i„�._
Street: 5 /:
e C e r nr e.e &_.
Village: Floor Plan: #Bedrooms: 3
Owner: A ro D JA o N`/ J3 0 r,54-7`41 Installer: 13 157a
Address: Phone:
Phone:
Builder: Engineer: D Qv.¢. Ic•,C1&$o
Address: Phone:
Phone:
N/A YES NO
1. Required#of copies received --
_
2. Date of soils exam and percolation test not older than 2 years
--
3. 4-5 ft of naturally occurring pervious material, above water table �
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5. Water line 10 ft from septic components Var.:
6. Benchmark indicated and shown-NGVD if near wetlands V
7. Septic tank minimum 10 ft from foundation,deck Var.: _
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9.Leaching minimum 100 ft from wetlands Var.:
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: V
11.Tank/leaching minimum 10 ft from property line Var.:
.:
i 12. System meets all other setback requirements Var.:
13. Uses adjustment for maximum high groundwater Var.: / '(,)44r i A N c.-e. 1.
-
14. Leaching set 4-5 ft above adj.'water or bottom of test hole Var.: ‘../..-
15.
-'15. System not in top or subsoil(A,B horizons)or 5' removal 1 .I/
16. Proposed contours are suitable
17. System meets slope requirements-min. 1/8", 'A"preferred i ,
18. System meets breakout requirements PVC liner: Wall: ✓/�
19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel
21.No garbage disposal V
22. System adequately sized for its intended use
23. Minimum 6"stone or compacted below tank and dbox
' 24. Manhole covers within 6"of grade, pump chamber cover to grade \--
25. Inspection port on plastic chambers/leach field
26. Electrical permit for pump chamber/Separate meter for duplexes
27.Pump system-2"line,weep hole,check valve, tee in dbox,pump size
28. Septic tank/pump chamber to be factory waterproofed
29. Vent provided if leaching below 3 feet,under driveway/parking /
30. Buoyancy calculations for tank/pump chamber
31. Engineer to inspect and certify soils: wall: commercial: 1/;••••",„
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33.H-20 loading is subject to vehicular traffic, groundwater 1
34.Title V Application and permit fee, installer signature v
35. Foundation footing min. 2 feet above adjusted ground water for new house /
36. Deed Restriction required max. #bedrooms: max. flow: gpd
37. Check area lots for groundwater/Label groundwa(/ter`in Assessor's Map V
Plan reviewed by: ^�,,�_ C�Vt
E- 30-01)- --