Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. 9•0 Lot 3 Zone of Contribution: In Out- Acreage,-, Q,S Ob 3 -F/ Commercial: Residential: Street: // 11 �"� e PC i ox) 4J�, Village: /Floor Plan: 1/ #Bedrooms: .q Owner: //t C w. Mc� ,c)-Y\4 f � Installer: R.Q<<j go f,ei-- Address: Phone: Phone: Builder: _ Engineer: M Cx/ e Address: _ Phone: /` s" Phone: N/A Y / NO 1. Required#of copies received 2. Date of soils exam and percolation test not older than 2 years 3. 4-5 ft of nattually occurring pervious material, above water table l 4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5. Water line 10 ft from septic components Var.: 6. Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9. Leaching minimum 100 ft from wetlands Var.: I .----- 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: . - 11. Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: t/ 13. Uses adjustment for maximum high groundwater Var.: 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: 15. System not in top or subsoil(A,B horizons)or 5' removal 16. Proposed contours are suitable I 17. System meets slope requirements-min. 1i8", %"preferred _ 18. System meets breakout requirements PVC liner: Wall: I 19. Specified tee sizes are proper, gas baffle on outlet tee i /...-- 20. Sewage is under 10,000 gpd for parcel i 21. No garbage disposal 22. System adequately sized for its intended use l -` 23. Minimum 6"stone or compacted below tank and dbox 24. Manhole covers within 6"of grade, pump chamber cover to grade 25. Inspection port on plastic chambers/leach field c - 26. Electrical permit for pump chamber/Separate meter for duplexes 27. Pump system-2"line,weep hole,check valve, tee in dbox,pump size 28. Se tic tankpump chamber to be factory waterproofed -)--- 29. Vent provided if leaching below 3 feet,under driveway/parking 30. Buoyancy calculations for tank/pump chamber 31. Engineer to inspect and certify soils: wall: commercial: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature j c.� 33. H-20 loading is subject to vehicular traffic, groundwater 34. Title V Application and permit fee, installer signature t 35. Foundation footing min. 2 feet above adjusted ground water for new house i l 36. Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/Label groundwater in Assessor's Map I l Plan reviewed by: s-e'09'C at-el---