Loading...
BLDE-22-000817 PLANS GOVERNING CODES ALL WORK SHALL CONFORM TO THE FOLLOWING COOES: 2015 INTERNATIONAL RESIDENTIAL CODE 2020 NATIONAL ELECTRICAL CODE 2015 NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION O e SHEET INDEX cpcPV 0.0•COVER SHEET PV 1.0•SITE PLAN S 1.0-MOUNT DETAILS E 1.0•ELECTRICAL DIAGRAM E 2.0•ELECTRICAL NOTES E 3.0•WARNING LABELS E 4,0-WARNING LABEL LOCATIONS E 6.0-BONDING DETAILS GENERAL ELECTRICAL NOTES GENERAL STRUCTURAL NOTES 1.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL 1.THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE MEANS DESIGNED AND LISTED FOR SUCH USE.FOR ROOF-MOUNTED SYSTEMS- ROCK-IT RAIL-LESS SYSTEM BY ECOFASTEN.THE MOUNTING FEET ARE TO BE WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF SPACED AS SHOWN IN THE DETAILS-AND MUST BE STAGGERED TO ADJACENT SURFACE. FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. 2.ANY CODE VIOLATIONS EVIDENT IN THE INTERCONNECTION PANEL WILL BE 2.UNLESS NOTED OTHERWISE SEES 1,0•MOUNTING ANCHORS SHALL BE 5/16'LAG CORRECTED ON INSTALLATION. SCREWS WITH A MINIMUM OF 2112'MIN PENETRATION INTO ROOF FRAMING. 3.SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE 3.THE PROPOSED PV SYSTEM ADDS 3.0 pat TO THE ROOF FRAMING SYSTEM 4.RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE 4.ROOF LIVE LOAD a 20 pat TYPICAL-0 pat UNDER NEW PV SYSTEM. INVERTER.RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCE 6.GROUND SNOW LOAD=30 psf VOLTAGE. O.WIND SPEED•140 mph •56 Michelle's Path, 5.SEE*E 1.0 AND'E 2.0 FOR DIAGRAMS-CALCULATIONS-SCHEDULE AND 1.EXPOSURE CATEGORY a S West Yarmouth,MA.. SPECIFICATIONS Vivint"Solar A sun run COMPANY 1800 ASHTON BLVD.LEm,UT,84043 1,871.404.4128 MAUC:17oM51laeeaA Mich '=elle Path PHOTOVOLTAIC SYSTEM SPECIFICATIONS SYSTEM SIZE•6.125KW DC l 7.6KW AC HYp$QII RESIDER CE Iv1ic'1'P11e' PAMODULE TYPE&AMOUNT-(25) JA SOLAR JAM80S17-325/MR WITH SOLAREDGE P370 OPTIMIZERS WEST 6YeARRM000TH,MA 0228733618 MODULE DIMENSIONS:(UW/H)88.5"138.2"/1,4" UTILITY ACCOUNT 14309580132 METER:2221002 INVERTER:(1)SOLAREDGE TECHNOLOGIES SE7600H-US INTERCONNECTION METHOD(GRID-TIED):SUPPLY TAP 825-0844385 D" O,O ROC:MA43 I"V DRAWN BY:DIN DATE:07/21/2021 REVISION:0 .r o. A CO ,- m m ce al IT aS • Z 130 O 1 K O (0 x = cm O s NOD r- Q r CO :////.//.)x .P ro 1 ir, A \\‘\s ' '.,,\,.. \ ` \\N\ A EIN 0 pJIJ m o_,m 0E: co GA x• O rr 11 o. Ci 1D cyJa OZ S00= C 1... g v® Cal di; %,yc < � ' goo I ;30_� ga A 4m7 3ri• B 2® 9�°4e i '43 +=19 3 CrdS $ AnL n g Z j xais E` Ell 2 aZ o Q 0 0110.0140)00,DATA)4-‘2.0 - MOUNTING NOTES ROCKMT COUPLING MIO CUMP M9CAd7 COUPLING .•Fr Ithe MG GIA.MPMY - � � 'Lr�4r' , 15l ...., ROM,SA COUPLING r Rosour I ROCWITELIDE 1110 OLMAP ' ► mem r � MIMI &NE r=77 AWING lb,POOr COUPLING NEAFWDESOLI SS , 900 aMEE!N '� � ROCKI7OOUKMO SHELF ,.,�.. I - I AMMO �i� COMP SWUM ,r•► IIIIIIIIIIII TOROUE•11}S PTO/ %-411 -- _.— MUM 1 1/1011 ur PL TIE PLATE HEX FLANGE BOLT ap�Yllti IooSERIES 61 r�_„_E' 5 NOT fi80A QRduNDINQ LUQ® � Ar. oill NOT TO 9 OUNT DETAIL 8 LO NOT TO®CAL@ ._ NOT I0 CAIfi OI.UrtNOFORKOFAST9.//63 40 FIK-IT A OWLINGAESEAAELY NEAP 1.9.. P*TTO SCALE MAX MOUNT SPACING vuta LANDSCAPE MOUNT SPACING•72' LUMP.ATTACHMENT,m LANDSCAPE CANTILEVER•24' CLAMP.ATTACHMENT,VP PORTRAIT MOUNT SPACING•4r COUPLING.TVP COUPLS9o.TVP PORTRAIT CANTILEVER•1e' R.IEE MOUNTING NOTES r I - MOUNT SPACING:SEE MOUNTING NOTES Ion CLUMP FRAMING,TAP MODULE.1YP RDCA,ReLloe - -iniummimi MODULE METAL , MODULE,rAP MASHING r MON SOWED WASHER �—FRAMING.TYP FRAMING.TYP ` FORMS WATERTIGHT SEK 1 t et ANNECAPE CLAW SPACING MEEEZZSZengSZIE • PV Y TSCAIE MMUNTINO DETAIL • MQD PQRTRAITILANDSCAPE I -I m. COMP M LES Ndf E , 6.11 MM 3'EON AND!V MAK BETWEEN TOP OF ROOF AND BOTTOM OP MODULE MNEI1C AM ONE ME STEEL 1TMP _ CONDUIT M$LAO WNW PI NODULE.TYP,MOUNT Allli1 TORCUENIAYFT•LB$. TO FRAMING OF EXISTING ROOF PLM PAMOF OOI LL IV WNPLANE E CONDUIT MOUNT ViV,n••SoIar I,MAE a sunrun cor ` 1e5o ASHTON BLVD.LEHn+I,UT�,84043v ,f 1 en.eaa1114p FLAMIM]OR TBE STRAP rp MA LI�:1TO01611ESSBA 111 'VMh t"ux,.W F:...tiwwFr+ll......•rr r.....vva......vwr ....11 wwx..... HIMELLE6�ATNCE 3 al=yy py �iyp �p�1N .... _ WEST YARMOUTH,MA 04673.1110 S 1.0 NOT Tb SCALE NB CALE ELEVATION N�i' �C6CAL@ iINO AIL UTILITYMETER:4451Do2ACCOUNT:MO 3510135 p MOUNT DETAILS ..A3 DIH S 1 F0 ROC:MA03 SCALE:NOT TO SCALE DAant 1 a s ocZ ;3 N 3C.. 3C.. TAW p5w GG a < 3. N Al;''''r�-.o I'-u: i2 W°r. N 3 Z [ 3 a di 8. 'mac > a s'1 0 3 0 3 3 C g.V. v W O O S w co) II, K a.3 pV at LI S N w a 0 re lie 3 E. 4 ^iZ ^ ^ " a -4 .'-' 4 # 1 ? -i19 z zAjt 4,42 La SaR c'�w S 1 • 4 U 6 w £ = o F. C El za"'- Z = g 5os •o = n 3• •• MZL.i x- L 2 '. y; z>o2 ,� ^ O A Y-M r {'J 3 `� g zoc1 giEE woQaogfol Q F- n fw� } 03 N---l1ow 's ;fa v 0 4~l r © w Q • Q * 3 y n N r > A N Z 0, p D y a 3 n 1 I U 11 Y Sog N"' u 3323 2 2 P3. gqq w r V S C • L A>N^A i . O .52I - _ , 2za v D 3 - c x j i INSTAU.E HINT SOLAR • ! Hudson Residence • m.e3-Line m INSTAi!£RNIqu :1.877.404.41 viv�nt.Solar 56MK}83IE5PA7H El Drawing - 1708481 15688A A s u n ru n co fvl PA N Y Yarmouth,MA 02673 6644368 I .Caped:7/21/21 Utility AceouN:1430 358 0139 Ineetter/Opdmiset glen PV Modulo Rating d sTC, Conductor Calculations Optimiser blare PS10 Module Make/Model JA Solar JAMe0917.845/MR Wire ampacity calculated from 310.16&17 as appropriate with ambient temperature DC Input Power 370 Wats M.Power-Point Currant pj 1.9 Amps. calculations from Table 310.15(8)(1)&310.15(3)(2)and raceway fill adjustments from 310.15(C) DC Max.Input Valap 6p Vola Max.Power-Point Voltage(Vmp) 33.97 Volts (1).Conduit on the roof shall be Installed no less than 1"above the roof deck. DC Max.Input Current 19.75 Amps Open-Circuit Voltage Not) 4017 VonsPV Circuit conductor ampacity Is constrained using the 75°C column with the continuous duty DC Max.Output Current 15 Amps Short-Circuit Current(Ise) 10.23 Amps uprating or the 90'C column with the relevant ambient temperature and raceway fill adjustments Max,string rating inverter dependent,See SE documents. Max.Series Fuse(OCP)) 20 Amps without the continuous duty upreting per 890,8(9),whichever results with a larger wire site, Inverter Make/Medal Salertdge 8g7600H-U$ Nom,Max.Power at STC(Pmax) 325 Watts Non-PV Circuit conductors use the ampacity In the 75'C column or the 90°C column with the CEC Efficiency 99 % Max.System Voltage 1000V/1500V DC(UL) relevant ambient temperature and raceway fill adjustments,whichever is less(110.14(C)& AC Operating Voltage 240 Volts Vee Temperature Coefficient -0.272 I %/c 310.14(A)(2)).The rating of the conductor after adjustments shall be greater than,or equal to, Cont.Max Output Current 32 Amps the continuous duty uprated current. DC Max Input Current 20 Amps AINRAE 2017-IARNS1A8iE MUNICIPAL, More information about conductor calculations can be provided upon request, Input Short Circuit Current 45 Amft Highest Monthly 2%0,1 Design Tempi 29,5'C Calc,Ex:Wire Ampacity x Ambient Temp.Corr,Factor x Conduit Fill Adj.Factor>.Output Current Max Output Fault Current 40A/20 ms Lowest Mln.Mean Extreme 0.8.:-19.2'C (Tag 1 Under Array): DC-to-DC Converter Output:10 AWG rated 30 A, 30 A>•WS A L. >.. (Tag 2 On Roof): 0 z Power Source(s)Output Clic:705.11 DC-to-DC Converter Output:12 AWG rated 20 A, 20 A>•18.75 A 0 a (Tag 3 Exterior): (/) g Service Rating:100 Amps Inverter Output:S 00.:AWG rated 5O A, 50 A n•40 Au PV Uprated Output Current:40 Amps (Tag 4 Exterior): CS 40A<•100A,OK Service Feeder:6 AWG rated 64 A, 65 A x•60 A •MIN. � N S •- Vl ' Q' is K Other Nota ..1 4 •Designed according to and all code citations are relevant to the 2020 National Electrical Code. •All Interior raceways carrying DC current shall be metallic, 1 Voltage and OCPD Calculations(690.7,690.9) PV Source Max Circuit Voltage:Module Voc a(1-(AT x Voc Coeff))(art.690.7(A)) JAM60517-325/MR:40.87 V x(11(25 C–.19.2 Cl x-0.272%))•45.78 V<.60 V 1 11;Inverter Output Circuit(+):Listed Output Current x 1.25(art.690.9(3)] SHEET Inverter 1:9E7600H•US Max Output■32 A x 1.25.40 A<.40 A(OCPD) NAME: System output current w/continuous duty•40 A<■40 A(System OCPD) SHEET NUMBER: seri I All AC Disconnecting Means-AC Dlsconnett(s), Conduit,Raceways,and 1-Bogies labeled Every 10')end Installed within 3 ft of Rapid Shutdown Switch,Reflective,end shall be placed on C.mb 1 Pen I ri •• • •• _ 1 •r . r ,, 4 Inverter 1 DC Disconnect•er 690.53 Reflective•er690.31(D)(2 the Exterior Pnext toORSDLocetioneper 690.36IC)IS) PHOTOVOLTAIC AC DISCONNECT MAXIMUM S SDE VOLTAGE v PHOTOVOLTAIC POWER SOURCE RAPID SHUTDOWN SWITCH MAXIMUM AC OPERATING CURRENT: 32A i 0 OF FOR SOLAR PV SYSTEM NOMINAL AC OPERATING VOLTAGE: 240 V 1 PV S stem Disconnects.or 690.11(B PV with Rapid Shutdown Switch,Installed within 3 ft of Service Disconnecting Moana with min.3/B"black capitalized text on yellow background&3/16" JAI& PV SYSTEM DISCONNECT black ce•It tired ext on hi eba r•und•er690.5,C L } az TURN RAPID SHUTDOWN 4 0 a SWITCH TO THE (i) "OFF"POSITION TO _ r, SHUTDOWN PV SYSTEM AND RSDUCE r •_ SHOCKOHAZARD IN ARRAY E, Mil I •; N 1 Plaque/Directory at Service Equipment Location and Power Production System Disconnecting dp¢ CAUTION: MULTIPLE SOURCES OF POWER platon Disconnecting dCe ters,andc mbiner POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE Panels per 890,13 8 61690.15 C FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS ELECTRICAL SHOCK HAZARD SHOWNTERMINALS ON THE LINE AND .r LOAD SIDES MAY BE ENERGIZED g IN THE OPEN POSITION r_ Power Source Output Connection,Adjacent to .. ' + T 1 9 •f,dBr ak r.er705,126 3 2 1-4 r • AT L 1 .. LT ...t METER AND MAIN POWER SOURCE OUTPUT CONNECTION SHEET ._._ SERVICE00 NOT RELOCATENAME � ,� THIS OVERCURRENT PROTECTION DEVICE AC DISCONNECT Dual Power Sources lnMain Service Penal and Sub P nal s ,er 705.12 C •SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF ARTICLES 690 AND 705,UNLESS OTHERWISE SPECIFIED PER \4. DC DISCONNECT LOCAL MU REQUIREMENTS•SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF SECTION 110.211B)AS REQUIRED PER ARTICLES 690 AND 705 AND SHALL COMPLY WITH ANSI 2535.4.2011,PRODUCT SAFETY SIGNS AND LABELS• I SIGNS/LABELS SHALL BE REFLECTIVE IF REQUIRED TO BE SO PER ARTICLE 690•SIGNS/LABELS MEETING NUMBER:SHEET DUAL POWER eouRa REQUIREMENTS OF ARTICLE 690 SHALL HAVE NO SMALLER THAN 3/8"WHITE TEXT ON RED BACKGROUND UNLESS SOURCES:UTILITY GRID OTHERWISE DEPICTED OR DESCRIBED•SIGNS/LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR AND PV SOLAR ELECTRIC SYSTEM WIRING METHOD AND SHALL NOT BE HANDWRITTEN•SIGNS/LABELS SHALL BE OF SUFFICIENT DURABILITY TO el LTH •T. I .• M N NV• .• • LA':. L •T • ER , MANUFACTURER LABELS W SITE PLACARD SHOWING ADDITIONAL POWER SOURCE WARNING I ®. MAXIMUM DC VOLTAGE RAPID SHUTDOWN SWITCH C qDUAL POWER SOURCE OF PV$VSTEM ""V FOR SOUR PVSYStfiM ANp DISCONNECT LOCATIONS.PLACARD SHALL BE1SOURCES:UTILITY GRIDMOUNTED ON EXTERIOR OF ELECTRICAL PANEL AND PV SOLAR ELECTRIC SYSTEM i� WARNING MAIN BREAKER DE-RATED 7 1 3 PHOTOVOLTAIC POWER SOURCE SOUR PV SYSTEM EQUIPPED TERMINALS ON THE LINE AND q DUE TO SOLAR CIRCUITS C WITH RAPID SHUTDOWN LOAD SIDES MAY BE ENERGIZED 11 ***AMPS MAX ALLOWED IN THE OPEN POSITION DO NOT UPGRADE A I. s �� PHOTOVOLTAIC AC DISCONNECT WARNING ( j PV SYSTEM DISCONNECT ( (� MAXIMUM AC OUTPUT CURRENT:'•'A POWER SOURCE OUTPUT CONNECTION / �/ NOMINAL AC OPERATING VOLTAGE:' V 00 NOT RELOCATE " THIS OVERCURRENT PROTECTION DEVICE 1- Y yr ROOFTOP ARRAY O • U 0 •IF APPLICABLE •> < n • 1 4 g INSIDE e 0 PANEL e 0 ct 0 00 00 so m9 00 EVERY 10'AND0 1 WITHIN 1'OF ELBOWS 7 ..‘ DC QZ ` DISCONNECT O 1i INSIDE W i 1 i ..- MO• OW••••.. SHEET ROOFTOPCOMBINER PANEL VISIBLE/LOCKABLE A/C VIVINT SOLAR METER VISIBLE/LOCKABLE A/C SUB PANEL MAIN SERVICE NAME: SOLAR INVERTER JUNCTION BOX 2 (WHEN USED) DISCONNECT(WHERE (WHERE REQUIRED) DISCONNECT (WHEN REQUIRED) DISCONNECT PANEL REQUIRED) `"'-value calculated for each TYPICAL SOLAR GENERATION INSTALLATION account,for specific value see the (NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION) previous warning label page SHEET NUMBER: •SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF ARTICLES 690 AND 705,UNLESS OTHERWISE SPECIFIED PER LOCAL AHJ REQUIREMENTS a SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF SECTION 110,21(8)AS REQUIRED PER ARTICLES 890 AND 705 AND SHALL COMPLY WITH ANSI 2535.4.2011,PRODUCT SAFETY SIGNS AND LABELS•SIGNS/LABELS SHALL BE REFLECTIVE IF REQUIRED TO BE SO PER ARTICLE 890•SIGNS/LABELS MEETING REQUIREMENTS OF ARTICLE 890 SHALL HAVE NO SMALLER THAN 3/B"WHITE TEXT ON RED BACKGROUND UNLESS OTHERWISE DEPICTED OR DESCRIBED•SIGNS/LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HANDWRITTEN•SIGNS/LABELS SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED•SIGNS/LABELS SHALL NOT CQVER EXISTING MANUFACTURER LABELS 7 BONDING NOTES qi•Ni=BONDING PATH -- MODULE FRAME tea,,--- . ROCK-IT COUPLING MID CLAMP *1►1O ....1,----, :,, . 7.11 "Mit1101:11 Al,'` 1 ROCK-IT ROCK-IT SLIDE UL2703:2018 LISTED PEDESTAL mr — BONDS SOLAR MODULE :.L- FRAME TO OPTIMIZER ;— OR MICRO-INVERTER ='"- £1. OPTIMIZER MOUNTED ORgyi<znti BONDING WITH U1.2703 TO MODULE FRAME �,,, ', SII, Q BONDING DETAIL WITH UL2703 PV MODULE TO ACT AS AN ACTIVE GROUNDING COMPONENT .TO EGC ■ II: EE l I . • GROUNDING LUG(SEE S1.0 DETAIL#2) •—+ E-W BONDING PATH. I N-S BONDING PATH,SEE DETAIL#1. 11 le ED ROCK•IT COUPLING vivint.Solar IL.___...._..___.. IL.._-----_._..___ = __..IB__ ._ ._._.__ um _II_.. A sunrun COIvirAzr 1600 ASHTON BLVD,LEH,UT,11013 0 ROCK-IT COUPLING IAA LI 10B'°��' SIA II - IS C II - 0 "UMWWEST YARMOUTH,MA 09173,7616 , UTILITY ACCOUNT;1430 3010130 MITER:2201002 CggggLpONDING LAYOUT WITH. UL2703 BONDING DETAILS rot= E 5,0 -. - - DRAWN SY.DIN SCALE:NOT TO SCALE DAM 02112021 1202 REVISION;0