Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLDE-21-005726
1091 Commonwealth of Official Use Only it Massachusetts Permit No. BLDE-21-005726 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:4/5/2021 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to pertorm the electrical work described below. Location(Street&Number) 801 WEST YARMOUTH RD Owner or Tenant Eviton DaSilva Telephone No. Owner's Address Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system.(19 Panels 6.175 KW) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Lloyd R Smith Licensee: Lloyd R Smith Signature LIC.NO.: 15688 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address:30 1ST ST,MELROSE MA 021764010 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 CImnwnweatth o`Na4.4aCktUdid Official Use Onl!^� -/ 0� 1 I. �, - cc�� c-� Permit No. ' .21eparimenl of Dire serviced Occupancy and Fee Checked BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC) 527 CMR 1 .00 (PLEASE PRINT IN INK OR TYP ALL INFORMA I Date: �� 1 City or Town of: G(,VCY> U� To the Inspector of Wires: By this application the undersigned gi es notice of his or her intention . ..- orm the electrical ork described below. Location(Street&Number) ro i I 1 A OP 1 Owner or Tenant ����� /1._ Telephone No. • �' r ZS-- Owner's Address stun �� ( o Is this permit in conjunction with a building permit? YesR No ❑ (Check Appropriate Box) Purpose of Building AJ( t ( rl - Utility Authorization No. Existing Service I27- Amps 12 U /2-L-1(- Its Overhead❑ Undgrd 0 No.of Meters I New Service Amps / Volts Overhead❑ Undgrd❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: 1 0 S INA n IP Ohofi Iiic� SC1CUN p6Crr 1 - (o . rrs Co letion of the followin&table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil-Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires swimming pool Above ❑ In- ❑ No.of Emergency Lighting g grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Tan No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained [ Totals: - _...._.... Detection/Alerting Devices M No.of Dishwashers Space/Area Heating KW Local 0 Con No. nunicipalection 0 Other No.of Dryers Heating Appliances KW 'Security Systems:* of Devices or Equivalent No.of Water KWNo.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent Bathtubs No.of Motors Total HP Telecommunications Wiring: No.Hydromassage No.of Devices or Equivalent OTHER: ^��/ — W Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of E ' 1 Work:I 1 Jlr� (When required by municipal policy.) Work to Start: 1 7 Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE CO RA E: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that suc coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE BOND 0 OTHER 0 (Specify:) I certify,under thfpains and penalties of perjutt the information on this # # #licati nn is true and complete. FIRM NAME: V \V\n C, \cL)IQ,v ll�^r"'� z LIC.NO.: Licensee: L.\(moi al c m t� Signatu .--f .S .NO.: I {CW.fr Pr (If applicable,enter"exempt"in the license number line.) Lam`rl - Bus.Tel.No.:_ Address: -)Ci' M \--e'-' S}'► 'i S i"1 v Ot 0 • Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)0 owner 0 owner's agent. Owner/Agent I PERMIT FEE:$ Signature Telephone No. jeh r\ ., . C%h A..rn 1.>-----1-5 U r'r..-x- . co rm S ..• !- • • .. ._ ![ 1 . i GOVERNING CODES ALL WORK SHALL CONFORM TO THE FOLLOWING CODER: 2015 INTERNATIONAL RESIDENTIAL CODE 2020 NATIONAL ELECTRICAL CODE 2015 NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION SHEET INDEX PV 0.0-COVER SHEET PV 1,0-SITE PLAN S 1.0-MOUNT DETAILS E 1.0-ELECTRICAL DIAGRAM E 2.0•ELECTRICAL NOTES E 3.0-WARNING LABELS E 4.0•WARNING LABEL LOCATIONS E 5.0-BONDING DETAILS GENERAL ELECTRICAL NOTES GENERAL STRUCTURAL NOTES 1.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL 1.THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE MEANS DESIGNED AND LISTED FOR SUCH USE.FOR ROOF-MOUNTED SYSTEMS. ROCK-IT RAIL"LESS SYSTEM BY ECOFASTEN.THE MOUNTING FEET ARE TO BE WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF SPACED AS SHOWN IN THE DETAILS.AND MUST BE STAGGERED TO ADJACENT SURFACE. FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. 2,ANY CODE VIOLATIONS EVIDENT IN THE INTERCONNECTION PANEL WILL BE 2.UNLESS NOTED OTHERWISE SEES 1.0•MOUNTING ANCHORS SHALL BE 5116"LAG CORRECTED ON INSTALLATION. SCREWS WITH A MINIMUM OF 2.112"MIN PENETRATION INTO ROOF FRAMING. 3.SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE 3.THE PROPOSED PV SYSTEM ADDS 3.0 pef TO THE ROOF FRAMING SYSTEM 4,RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE 4.ROOF LIVE LOAD•20 pef TYPICAL.0 pef UNDER NEW PV SYSTEM. INVERTER.RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCE 5.GROUND SNOW LOAD•30 pef V�y�l1t.e Iqr VOLTAGE. S.WIND SPEED•140 mph 5.BEE•E 1.0 AND"E 2.0 FOR DIAGRAMS.CALCULATIONS-SCHEDULE AND 7,EXPOSURE CATEGORY•B A Sun run c o r.1 rA r SPECIFICATIONS 100 ASHTON MVO.LEHI,UT,54043 .:.,..:.:.;.. 13T7A04A170 ..- MA LM:110$4$1155$$A DASILVA RESIDENCE PHOTOVOLTAIC SYSTEM SPECIFICATIONSio1WYARMOUTH RC YARMOUTH FORT,MA 07576 SYSTEM SIZE-8.175KW DC I 7.6KW AC a1 imNMETER:7T 14757230043 MODULE TYPE&AMOUNT•(19) JINKO SOLAR JKM325M-80HBL WITH SOLAREDGE P370 OPTIMIZERS MODULE DIMENSIONS:(L/W/H)86.3"!39.5"11.4" n7Feaozaee R INVERTER:(1)SOLAREDGE TECHNOLOGIES SE7800H-US ROC:MA-03 PV 0.01 INTERCONNECTION METHOD(GRID TIED):SUPPLY TAP DATTE:05711412021 REVISION;0 !• PV STRINGS: ROOF SECTIONS: SYSTEM LEGEND r 4,/ PV STRING 1.10 MODULES ROOF PLANE 1 SLOPE•28° PV SYSTEM SIZE: PV STRING 2.6 MODULES ROOF PLANE 1 AZIMUTH•93° (N)8.175kW DCI 7.600kW AC ROOF 1 MAT•COMPOSITION SHINGLE I m l STN 61 INTERIOR:TIED II ROOF PLANE 2 SLOPE•28' UT 7:51' M METER 2361372. ROOF PLANE 2 AZIMUTH•273° 171 X36972)2ET's UTILITY METER ROOF 2 MAT•COMPOSITION SHINGLE 111 P s1 0 ROOF PLANE 3 SLOPE•28° nig MERRY MBTER,LOCATED WITHIN t0 ROOF M ROOF 3 MATPLANE COMPOSITION3 AZIMUTH °SHINGLE ®IN)PV SYSTEM AC DISCONNECT. (N)I PV STRING INVERTER: m(N) LA � (N)16 ANKO SOLAR k017?6M201B MODULES T OPTIMIZERS MOUNTED ON THEBACKOFEACH MODULE. N) JUNCTION X./ =MOUNTED WITH 30 AUECK) O h 3 . O \\ % N �� vi nrun co olar O \&.\\k\\\' { T I 16W ASHTON BLVD.LEHI,UT,64043 Z ` * 1.677.4010420 MA LIC:170648 116886A DASILVA RESIDENCE 601 WYOUTHRD YARMOUTH PORT,MA 02675 UTILITY ACCOUNT:1466 723 00{3 METER:2362372 SITEPLAN SE B4602246 62 PV 1.0 AROC:SCALE:1/8"=V-0" DATE:DRAWN 803 2021 REVISION: B MOUNTING NOTES RODE-IT COUPLING MDCAP ROCN•RIDUPLNo AI MIG aAAw NV ltbrir jd1111114 .1114 _. ROGNTA,000UPLING MDC AW ..-:....'lip...', , ROCIWT ' how BADE 1 PEDESTAL METH. ROCIHR dllyde• FIABNNO 044 COUPLNO SHELF ': HEX FLANGE IGT all A....., ROGWr COMING SHELF A \: SO0 soon COMP SHINGLES . S>r SO AG SCNEW * TOROUE•123BP14J. • '� MU %40 t : d11 i it2. T8 PLATE NEM FLANGE BOLT S ILSCU SOS-4 GROUNDING LUGS vs= 3C0 BIRO SS immi_.i 1 ROCK-IT 3.0 MOUNT DETAILs tD 1401TO LEE s 10 NOT MIME — U1.11fNDFOP=FASTEN:moi a ROCK-/T 3.0 COUPLING ASSEMBLY WOO MP. I10 NotroSONA Ma MAX MOUNT SPACING CLAMP•ATTACHMENT,TYP CLAMP-,ATrACHME1IT rvP LANDSCAPE MOUNT SPACING•31" COUPLING,MA ..mA COUPLING.TYP LANDSCAPE CANTILEVER•21" ILflvNI:BER MOUNfl/O NQ1E9 r 01 PORTRAIT CANTILEVER•UPORTRAIT MOUNT r•41' MOUNT SPACING:SEE MOUNTING NOTES ROCK-IT SLIDE � CLAW MIMING TYP WWII,TM P"uE METAL MODULE,T4 FLASHING ...4 I RPM IONDED WASHER ..---FUMING.TYP FRAMING,M. FORME WATERTIGHT SEAL I. I LALANDScA•/CLAMP SPACING As A PV SYSTEM MOUNTING DETAIL S MODULES IN PORTRAIT/LANDSCAPE L. I. cas A Irlo 31.0 NDTTR ELLE 31.0 HOT TOECALP COW SHINGLES s•MN AND t ox SEMEN TOP OF ROOF ANO BOTTOM OF MOOUB MN d1e.OWA ONE HOLE STEEL STRAP CONDUIT SE IAO BCREW PH MODULE,TMP.MOUNT Albi TOggUE•18f4 FTiBL TO MIMING MIL N 1441ARALL31L L. RDOIBOO1 WITH PLANE OF RDOF CONDUIT MOUNT SMOOT + dMAMMA ' VIVRILSolar SECTION VIEW 1 t 1• A suA4Ht FUFL D.LE PA N V // FLAMMOATILE STRAP �� MOASHTONIIW).LKUT,840/3 NA IICtermB c 1 rfLarhwtrwll.IV WNe*Pr�rlwwNw/•ria+.Jrwawwni*o.avinY.+w.YW14+u NiifiNf.+.r+f:4+u. 2 SECTION p A SID CE s omls� B PV ARRAY TYP.ELEVATION T CONDUIT MOUNTING pETL $01WYMYARMOUTH 00201E 31,0 Not Toiou 8 LA POT To Ac48 ummACCOUNT:1466 723 0043 - - . METER:23023T2 MOUNT DETAILS S 1.0/ SCALE;NOT TO SCALE DATE:03/2212021 REVISION:Q 13* 1 «3q . © ■ §(\ kk: to' - © ` 5§ Ill owl 7' 1e' Ill Ai '.i `.1 § 9 ` 2."� ""1".. '.: ],ƒ ; ,fie t4.0 !z g U 3 i E IS \\/ o --, - -4 rwn aXX aaa /}}\ C - ! ®B}. | 'E \ 2 II 1111111111 II | ;72E 7 & ^$ •k /E ®&_!! • I 2 k 2 L} ( DIII / 2 Ft o.11111 7� ){ I I .� �l g II /« 3 1 � � 7§ k kkk .} k . k20I % ,}� 1 . %aei .4.f1 | *a§ 2 5/0- � llg ;e [ , .., !« -_! 7 * \: » / I I {f{ 5 I fi 5. limmumnim § £! § ! § ia r! X2$7 - . £ £ (= $fƒ 7 « t g !%If 3»i§§$$$ ir. «: .k ■2I2 '\§ aVA/817 501AR Danli >d V�¥fin SOS� _ _1.877A04.4129801 W Tannouth ad £! — ?? Drawing 170848 1 156888 »2nenCA-N Y Yarmouth,ee_ 6602265 1 Creme&3/22/21 Utffity__723 0043 Inventer/°Omuer9p to A PV Module Retina e$Tc Conductor Calculations Optimiser WA*P870 Module Make/Model llnko Solar JKM929M-80861. DC Input Power 370 War Max Power-Point Current(imp) 9,68 Amps Wire ampacity calculated from 310.16&17 as appropriate with ambient temperature DC Max input Voltage 60 Volta Max,Power Point Voltage(Vmp) 33.6dI . Volts calculations from Table 310.15(8)(1)&310.15(10(2)and raceway fill adjustments from 310.15(C) 121 r� DC Max.Input Current 13.75 Amps Open-Circuit Voltage(Vise) 41.1 Vohs (1),Conduit on the roof shall be installed no less than 1"above the roof deck, e PV Circuit conductor empacity is constrained using the 75•C column with the continuous duty '" DC Max.Output Current 15.Amps Short-Circuit Current fisc) 10.2 Amps, uprating or the 90•C column with the relevant ambient temperature and raceway fill adjustments > Max.string rating Inverter dependent.See SE documents. Max.Series Fuse(OCPO) 20 Amps without the continuous duty uprating per 690.6(6),whichever results with a larger wire size. II I ; Inverter Make/Model Solartdge 817600H-US Nom.Max.Power at STC(Pmax) 325 Watts Non-PV Circuit conductors use the ampacity In the 75•C column or the 90'C column with the i" CEC Efficiency 16 % Max.System Voltage 1000 VDC(UL/IEC) relevant ambient temperature and raceway fill adjustments,whichever Is less(110.14(C)& AC Operating Voltage 240 Volts Voc Temperature CoefficIent -0.28 196/[ 310.14(A)(2)).The rating of the conductor after adjustments shall be greater than,or equal to, Cont.Max Output Current 32 Amps the continuous duty uprated current. DC Max input Current 20 Amps ASHRAE 2017-BARNSTABLE MUNICIPAL More information about conductor calculations can be provided upon request. Input Short Circuit Current 45 Amps Highest Monthly 2%179,Design Tempo 29.5 T Calc.Ex;Wire Ampetlty x Ambient Temp.Corr.Factor z Conduit Fill Adj.Factor>.Output Currant Max Output Fault Current 4D P120 ms Lowest Mln,Mean Extreme DA;-19.2'C (Tag 1 Under Array): ._. DC-to-DC Converter Output;10 AWG rated 30 A, 30 A>•16.75 A > (Tag 2 Attc): z Power Souree(s)Output Cele:705.11 DC-to-DC Converter Output:12 AWG rated 30 A, 30 A x 0,76 x 0.8.18.24 A>=15 A Q a (Tag 3 On Roof): CO 6 Service Rating:400 Amps DC-to-DC Converter Output:12 AWG rated 20 A, 20 A>•18.75 A • c' PV Breaker Rating:40 Amps (Tag 4 Exterior): = v C 40A<•400A,OK inverter Output:8 AWG rated 50 A, 50 A>•40 A .isini (Tag 5 Exterior): ` C Service Feeder:6 AWG rated 65 A, 65 A>•BOA •` vii t Other Notes I •Designed according to and ail code citations are relevant to the 2020 National Electrical Code. •All interior raceways carrying DC current shall be metallic, Voltage and OCPD Calculations(690.7,690.9) PV Source Max Circuit Voltage:Module Voc x(1-(11'x Voc Coeff))[art.690.7(A)) JKM325M-60HBL:41,1 V x(1-((25 C—-19.2 C)x-0.28%))•46.19 V<•60 V / 111 Inverter Output ClrtWt(s);Listed Output Current x 1.25(art.690.9(8)) SHEET Inverter 1;SE7600H-US Max Output=32 A x 1,25=40 A<=40 A(OCPD) NAME; System output current w/continuous duty•40 A<•40 A(System OCPD) 1 r SHEET NUMBER: n W r,. All AC Disconnecting Means-AC Disconnect(s), Conduit,Raceways,and 1•8oxes(Labeled Every 10')and Installed within 3 ft of Rapid Shutdown Switch,Reflective,end shall be pieced on C. .e P ,Is an• . • n; ,'r 690, 4 Q inverter 1 DC Disconnect•er 690.53 ii Reflective per 690.31(D)(2) both Panel Exterior next to Main Disconnect par per PHOTOVOLTAIC AC DISCONNECT MAXIMUM DC VOLTAGE PHOTOVOLTAIC POWER SOURCE RAPID SHUTDOWN SWITCH MAXIMUM ACOPERATING CURRENT: 32 OF PV SYSTEM: 480 v FOR SOLAR PV SYSTEM NOMINAL AC OPERATING VOLTAGE 240 V 4 PV S stem Disconnects.or 690.13 B PV with Rapid Shutdown Switch,Installed within 3 ft of Service DisconnectingN PV SYSTEM DISCONNECT Means with kca.ItB"blase ton whed ite extbac roundn sr690,56Cd&3/16" 23 bl cka•Italisedtextonwhitebac round•er640,58C } 4 .441—,,14,..t w,41.,,e4 Y` 0 TURN RAPID SHUTDOWN Q SWITCH TO THE P CO "OFF"POSITION TO __, } o SHUTDOWN PV SYSTEM AND REDUCE @ C SHOCK HAZARD € •� `- g. IN ARRAY MI •> j Pie•us/Directs) at Service Disconnectin Means•er 690.56(B),&705.10 s, ' ) CAUTION; MULTIPLESOURCES OF POWERDisco„ect(s),Lo dDisconnectinCenters,a dMeans• CCombiner POWER TO THISBUILDING IS ALSO SUPPLIED FROM THE Panels•er590.13(8 &690.15 Fia FOLLOWING SOURCES WITH I1SCONNECTS LOCATED AS YY4 lLECTRICAL SHOCK HAZARD .SHOWN TERMINALS ON THE LINE AND i LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION L<- i Power Source Output Connection,Adjacent to A Be Wild Br akar•ar 705.12 8 3 I --• A : j� i L 1._..L__ l X� 'Y METER ER AND MAIN POWER SOURCE OUTPUT CONNECTION SHEET r-_- r_I '-�` ;M DO NOT RELOCATE 1 SERVICE NAME: / 1 \ I 4 -I THIS OVERCURRENT PROTECTION DEVICE '\ - T 1 ACDISCONNECT Dual Power Sources in Main Service Panel DC DISCONNECT and Sub Panelspar 705,12 C ••SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF ARTICLES 690 AND 705,UNLESS OTHERWISE SPECIFIED PER ++ LOCAL ANI REQUIREMENTS•SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF SECTION 110.21(B)AS REQUIRED II Ill J' DUAL POWER OURCI PER ARTICLES 600 AND 709 AND SHALL COMPLY WITH ANSI 2535.4-2011,PRODUCT SAFETY SIGNS AND LABELS• SHEET SIGNS/LABELS SHALL BE REFLECTIVE IF REQUIRED TO BE SO PER ARTICLE 690•SIGNS/LABELS MEETING NUMBER: SOURCES:UTILITY GRID REQUIREMENTS OF ARTICLE 690 SHALL HAVE NO SMALLER THAN 3/B"WHITE TEXT ON RED BACKGROUND UNLESS OTHERWISE DEPICTED OR DESCRIBED•SIGNS/LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR AND PV SOLAR ELECTRIC SYSTEM WIRING METHOD AND SHALL NOT BE HANDWRITTEN•SIGNS/LABELS SHALL BE OF SUFFICIENT DURABILITY TO tMi ITHJTANO THE ENVIRONMENT INVOLVED•SIGNS/LABELS SHALL N T COVER EXISTING MANUFACTURERIABELS M WARNING SITE PLACARD SHOWING ADDITIONAL POWER SOURCE ^a MAXIMUM DC VOLTAGE RAPID SHUTDOWN SWITCH ND g DUAL POWER SOURCE $OF PV SYSTEM •"*V 4FOR SOLAR PV SYSTEM AMOUNTED ON ExrER10RpOF ELECTRICAL PANlDISCONNECT LOCATINS.PLACARD SHALL gE SOURCES:UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM Ii WARNING MAIN BREAKER DE-RATED 1 I jIiW'C PHOTOVOLTAIC POWER SOURCE �,.� SOLAR PV SYSTEM EQUIPPED TERMINALS ON THE LINE AND q q DUE TO SOLAR CIRCUITS ( , i WITH RAPID SHUTDOWN LOAD SIDES MAY BE ENERGIZED 11 **'AMPS MAX ALLOWED HO\• fIN THE OPEN POSITION DO NOT UPGRADE /,� /�\ PHOTOVOLTAIC AC DISCONNECT WARNING ( j DV SYSTEM DISCONNECT ( (j MAXIMUM AC OUTPUT CURRENT:***A �, POWER SOURCE OUTPUT CONNECTION �/ / NOMINAL AC OPERATING VOLTAGE;***V ,/ DO NOT RELOCATE THIS OVERCURRENT PROTECTION DEVICE a 1 ROOFTOP ARRAY Q a © • O } V /c C i_ 7 •5 V C 0 •IF APPLICABLE •' a 1 4 O 0 INSIDE 0 0 PANEL © o ® ® ® ® 6o mo � a EVERY 10'AND WITHIN 1'OF ELBOWS e IN DC 0 0 DISCONNECT M 1 1 " INSIDE - Z ..- ... ..—. SHEET ROOFTOP COMBINER PANEL VISIBLE/LOCKABLE A/C VIVINT SOLAR METER VISIBLE/LOCKABLE A/C SUB PANEL MAIN SERVICE NAME 2 ' • SOLAR INVERTER JUNCTION BOX (WHEN USED) DISCONNECT(WHERE (WHERE REQUIRED) DISCONNECT (WHEN REQUIRED) DISCONNECT PANEL REQUIRED) """•value calculated for each TYPICAL SOLAR GENERATION INSTALLATION account,for specific value see the (NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION) preVlous warning label page SHEET NUMBER: •SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF ARTICLES 690 AND 705,UNLESS OTHERWISE SPECIFIED PER LOCAL AHJ REQUIREMENTS•SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF SECTION 110.21(B(AS REQUIRED PER ARTICLES 690 AND 701 AND SHALL COMPLY WITH ANSI 2535.4.2011,PRODUCT SAFETY SIGNS AND LABELS•SIGNS/LABELS SHALL BE REFLECTIVE IF REQUIRED TO BE SO PER ARTICLE 690•SIGNS/LABELS MEETING REQUIREMENTS OF ARTICLE 690 SHALL HAVE NO SMALLER THAN 3/B"WHITE TEXT ON RED BACKGROUND UNLESS OTHERWISE DEPICTED OR DESCRIBED•SIGNS/LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HANDWRITTEN•SIGNS/LABELS SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE rt ENVIRONMENT INVOLVED•SIGNS/LABELS SHALL NOT COVER EXISTING MANUFACTURER LABELS IJ • NOTES �r BONDING PATH MODULE FRAME a_M: ROCK-IT COUPLING MID CLAMP HUM � I �. �I�n�� f 'fit_• , ROCK-IT ROCK-IT SLIDE UL2703:2015 LISTED PEDESTAL fl---- ' BONDING CLIP ■■� `- -J BONDS SOLAR MODULE '=� ..L FRAME TO OPTIMIZER OR MICRO-INVERTER "'" ;i OPTIMIZER MOUNTED I 1 BONDING WITH UL2703 TOMODULEFRAME0çgr. '1TEGRATED ��� I�� SII .�, ®20cgliciFF BONDING DETAIL WITH UL2703 PV MODULE TO ACT AS AN ACTIVE GROUNDING COMPONENT TOEGO isismsol inium----io- -1• GROUNDING LUG(SEE S1.0 DETAIL#2) • + E-W BONDING PATH. mo--- ini-ii- NSBONDING PATH,SEE DETAIL#1, ElROCK-IT COUPLING Vivint.Solar 11 A sunrun run',A<r IIIIINIIIIIIIIIIIN 1600 ASHiON SLVO.LEHL UT,84043 0 ROCK-IT COUPLING MALIC116 1&IBA 11 gA174WDE 11 C 11 O 11 11 YARMOUTH PORT,MA 02676 UTILITY ACCOUNT;14667230043 ; METER:2362372 1 eggoONDINe LAYOUT WITH U1,2703 BONDING DETAILS E 5.01 DRAWN BY DIN SCALE:NOT TO SCALE DATE.0312212021 REVISION:0 .�