Loading...
HomeMy WebLinkAboutEngineer Plan16 9 SURVEY BY: 20�� ti30 / OA 18 \W \ PROP. 1,500G 20.8 SEPTIC TANK \ 18. �/ LOT \ 3 AREA = 16b00 sf+— �LAN BOOK 137\PAGE 115 ASSR ID:28-7\-12-3 18, O \ \ WELLER & ASSOCIATES X O 10 20 BM = EL. 22.0 BULKHEAD FOUNDATION Ib VARIANCE REQUESTS - MAXIMUM FEASIPLE COMPLIANCE 0 9.6 --' re— 'o- zl. 20 LEGEND PROPOSED CONTOUR ® PROPOSED SPOT GRADE --98 -- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE —W— EXISTING WATER SERVICE TEST PIT SCALE: 1"=30' iamOHth Red& Deparbust Date SEP 012022 HATH DEPT. PER 310 CMR 15.405 (1) (Bl 1) A 5.5 FT. VARIANCE FROM 310 CMR 15.211 TO ALLOW PROP. LEACHING TO 8 A MIN. OF 18.4' FROM DWELLING VS, REQUIRED 20 FT. FIRST FLOOR WEST YARMOUTH LOCUS N 45 TAFT RD. P. LOCUS MAP LOCUS INFORMATION PLAN REF: LCP 33984—A (SHEET 2) TITLE REF: LCC 154954 PARCEL ID: MAP 058 LOT 068 PROPERTY IS NOT IN ZONE II FLOOD ZONE: NOT IN FLOOD ZONE COMMUNITY PANEL: 25001CO591J DATED:07/16/14 SEPTIC SYSTEM z REPAIR PLAN LOCATED AT: 45 TAFT ROAD WEST YARMOUTH, MA 1 PREPARED FOR CYNTHIA MANCINI SECOND FLOOR 19. 2022 STEVEN W, 41Ct RUMBANQ. 35291 R 1140 MEYER & SONS INC. P.O. Box 981 E. SANDWICH, MA 02537 PH. (508)360-3311 fax (774)413-9468 meyerandsonstitle50gmail.com F.F. ELEV. (Existing) = 23.0 INV: 20.17 INV- 18.57 TEE'S ARE TO 4" SCH 40 F BAFFLE INV. 18.32 PROP. 1,500 GALLON SEPTIC TANK GAS BAFFLE TO BEI STALLED ON OUTLET TEE AS MAN FACTURED BY TUF-TITE, ZABEL, OR EQUAL NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION 2) TANK AND D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2) 3) INSTALL INLET & OUTLET TEES W/ GAS BAFFLE AS REQUIRED INV. 18.1 PROPOSED DB -3 DISTRIBUTION BOX (H20) SEPTIC SYSTEM PROFILE SOIL LOGS DATE: MAY 26, 2022 SOIL EVALUATOR: DARREN MEYER, RS, CES 614 WITNESS: JAY GARDINER, YARMOUTH HEALTH Elev. 19.30 17.80 17.22 15.72 PERC EL. 14.30 12.05 TP -1 NOTE: PLACE MAGNETIC MARKING TAPE OVER ALL COVERS t OYR 4/1 B BRING LEACHING COVERS TO W/IN 3" OF FINISH GRADE BRING ALL COVERS TO FINISH GRADE W/METAL RINGS C MEDIUM AND COVERS. SAND FINISHED GRADE 20.0) '.G.EL: 20.80 F.G. EL: 42.00 MAINTAIN 2% MIN SLOPE OVER LEACHING AREA BAFFLE INV. 18.32 PROP. 1,500 GALLON SEPTIC TANK GAS BAFFLE TO BEI STALLED ON OUTLET TEE AS MAN FACTURED BY TUF-TITE, ZABEL, OR EQUAL NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION 2) TANK AND D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2) 3) INSTALL INLET & OUTLET TEES W/ GAS BAFFLE AS REQUIRED INV. 18.1 PROPOSED DB -3 DISTRIBUTION BOX (H20) SEPTIC SYSTEM PROFILE SOIL LOGS DATE: MAY 26, 2022 SOIL EVALUATOR: DARREN MEYER, RS, CES 614 WITNESS: JAY GARDINER, YARMOUTH HEALTH Elev. 19.30 17.80 17.22 15.72 PERC EL. 14.30 12.05 TP -1 Depth 0" 181, 25" 43" 87" S ILS HORIZONS IN THE F ONT YARD DIFFER FROM S ILS IN THE REAR YARD. 8.97 1 1 124" PERC RATE <2 MIN/IN. ("C" HORIZON) GROUNDWATER OBSERVED AT 124" EL. 8.97 WELL, MIW-29 ZONE: A LEVEL: 7.9 ADJ: USE ADJUSTED GROUNDWATER EL. 10.47 2" OF 3/8" DOUBLE WASHED STONE OR FILTER FABRIC 4" SCH 40 PVC 1% (MIN. 2 E F. DEPTH 17.95 TOP CONC. ELEV.= 18.57 INV. ELEV.= 17.57_ BOTTOM EL. 15.57 SEPARATION 5.10 FT. ADJ. GROUNDWATER EL: 10.47 GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPDCABLE LOCAL RULES AND REGULATIONS, EXCEPT LISTED ON PAGE 1. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE. DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY .PROVIDED BY TOWN WATER SERVICE. 6.ALL AREAS -0ISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. R SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE THE LOCATION OF ALL UNDERGROUND UDLTnES, PRIOR TO BEGINNING CONSTRUCTION. 10. EXISTING TANK/LEACHING TO BE PUMPED, CRUSHED AND REMOVED PER TITLE 5. REPLACE W/ CLEAN MEDIUM SAND PER TITLE 5. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY UNE SURVEY 13.. NO PRIVATE WELLS WITHIN 150' OF PROPOSED LEACHING. 14. ALL PIPING TO BE 4" SCH 40 0 1/8"/FT (UNLESS SPECIFIED) 15. A 5 FT SOIL REMOVAL MAY BE NECESSARY TO TOP OF "C" LAYER. 16. LANDSCAPE TIMBERS TO BE PLACED AT EDGE OF DRIVEWAY, ALONG TANK, TO PREVENT VEHICULAR TRAFFIC OVER TANK. 17. PLACE 40 ml POLY LINER AS SHOWN, FROM EL. 18.5-14.5 TO PREVENT LEACHING INFILTRATION 3/4 1 -1/2 - DOUBLE WASHED STONE 0 BREAKOUT ELEV.= 18.57 3.75' 1 5 FT. I 3.75' EFFECTIVE WIDTH = 12.5' SOIL ABSORPTION SYSTEM (SECTION) 500 GALLON H-20 LEACH CHAMBER; DESIGN CRITERIA NUMBER OF BEDROOMS: 4 BEDROOM DESIGN SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 110 G.P.D. X 4 BR = 440 G.P.D. GARBAGE GRINDER: NO (not designed for garbage grinder) SEPTIC TANK: 440 gpd x 200% = 880 gpd, USE PROP. 1,500 GAL. SEPTIC TANK LEACHING AREA REQUIRED: (440)/0.74 = 594.59 S.F. USE THREE (3) 500 GALLON H-20 PRECAST LEACH CHAMBERS W/ 4' STONE ON ENDS & 3.75' STONE ON SIDES: 33.5' L x 12.5' W x 2'D BOTTOM AREA: 33.5 x 12.5 = 418.75 SF SIDE AREA: (33.5 + 12.5) X 2 X 2 = 184 SF TOTAL SQUARE FEET PROVIDED = 602 vs. 594.59 REQ'D DESIGN FLOW PROVIDED: 0.74(602 S.F.) = 445.48 G.P.D. vs. 440 G.P.D. req'd PROPOSED SEPTIC SYSTEM UPGRADE PLAN 45 TAFT ROAD, WEST YARMOUTH, MA Prepared for: Cynthia Mancini Design and Site Plan by; SCALE DRAWN DATE MEYER& SONS, INC. N,T,S, DMM 07/19/22 PO BOX 981 REV DATE EAST SANDWICH, MA 02537 CHECKED SHEET NO. 508.362-2922 DMM 2 of 2 FILL LOAMY SAND t OYR 4/1 B LOAMY SAND 10YR 5/8 C MEDIUM SAND 2.5Y 6/4 C2 MEDIUM SAND 2.5Y 7/3 Depth 0" 181, 25" 43" 87" S ILS HORIZONS IN THE F ONT YARD DIFFER FROM S ILS IN THE REAR YARD. 8.97 1 1 124" PERC RATE <2 MIN/IN. ("C" HORIZON) GROUNDWATER OBSERVED AT 124" EL. 8.97 WELL, MIW-29 ZONE: A LEVEL: 7.9 ADJ: USE ADJUSTED GROUNDWATER EL. 10.47 2" OF 3/8" DOUBLE WASHED STONE OR FILTER FABRIC 4" SCH 40 PVC 1% (MIN. 2 E F. DEPTH 17.95 TOP CONC. ELEV.= 18.57 INV. ELEV.= 17.57_ BOTTOM EL. 15.57 SEPARATION 5.10 FT. ADJ. GROUNDWATER EL: 10.47 GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPDCABLE LOCAL RULES AND REGULATIONS, EXCEPT LISTED ON PAGE 1. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE. DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY .PROVIDED BY TOWN WATER SERVICE. 6.ALL AREAS -0ISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. R SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE THE LOCATION OF ALL UNDERGROUND UDLTnES, PRIOR TO BEGINNING CONSTRUCTION. 10. EXISTING TANK/LEACHING TO BE PUMPED, CRUSHED AND REMOVED PER TITLE 5. REPLACE W/ CLEAN MEDIUM SAND PER TITLE 5. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY UNE SURVEY 13.. NO PRIVATE WELLS WITHIN 150' OF PROPOSED LEACHING. 14. ALL PIPING TO BE 4" SCH 40 0 1/8"/FT (UNLESS SPECIFIED) 15. A 5 FT SOIL REMOVAL MAY BE NECESSARY TO TOP OF "C" LAYER. 16. LANDSCAPE TIMBERS TO BE PLACED AT EDGE OF DRIVEWAY, ALONG TANK, TO PREVENT VEHICULAR TRAFFIC OVER TANK. 17. PLACE 40 ml POLY LINER AS SHOWN, FROM EL. 18.5-14.5 TO PREVENT LEACHING INFILTRATION 3/4 1 -1/2 - DOUBLE WASHED STONE 0 BREAKOUT ELEV.= 18.57 3.75' 1 5 FT. I 3.75' EFFECTIVE WIDTH = 12.5' SOIL ABSORPTION SYSTEM (SECTION) 500 GALLON H-20 LEACH CHAMBER; DESIGN CRITERIA NUMBER OF BEDROOMS: 4 BEDROOM DESIGN SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 110 G.P.D. X 4 BR = 440 G.P.D. GARBAGE GRINDER: NO (not designed for garbage grinder) SEPTIC TANK: 440 gpd x 200% = 880 gpd, USE PROP. 1,500 GAL. SEPTIC TANK LEACHING AREA REQUIRED: (440)/0.74 = 594.59 S.F. USE THREE (3) 500 GALLON H-20 PRECAST LEACH CHAMBERS W/ 4' STONE ON ENDS & 3.75' STONE ON SIDES: 33.5' L x 12.5' W x 2'D BOTTOM AREA: 33.5 x 12.5 = 418.75 SF SIDE AREA: (33.5 + 12.5) X 2 X 2 = 184 SF TOTAL SQUARE FEET PROVIDED = 602 vs. 594.59 REQ'D DESIGN FLOW PROVIDED: 0.74(602 S.F.) = 445.48 G.P.D. vs. 440 G.P.D. req'd PROPOSED SEPTIC SYSTEM UPGRADE PLAN 45 TAFT ROAD, WEST YARMOUTH, MA Prepared for: Cynthia Mancini Design and Site Plan by; SCALE DRAWN DATE MEYER& SONS, INC. N,T,S, DMM 07/19/22 PO BOX 981 REV DATE EAST SANDWICH, MA 02537 CHECKED SHEET NO. 508.362-2922 DMM 2 of 2