HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
•
Location: A.M. Lot 3O 3/ Zone of Contribution: In Out V Acreage/Q �j 6
( Commercial: Residential: '�
Street: a C�f G., 1 Xl
Village: Floor `
/ Plan: f # Bedrooms:_
Owner: Q, ak. r S c C.,,{Cc L Installer: `ems i k.e 30rSel/C.,
Address: Phone:
Phone:
Builder: Engineer: A
Address: Phone:
Phone:
N/A YES I NO
Required#of copies received
Li
2. Date of soils exam and percolation test not older than 2 years
3. 4-5 ft of naturally occurring pervious material, above water table v
4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: v
5. Water line 10 ft from septic components Var.:
6. Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.:
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: I
9. Leaching minimum 100 ft from wetlands Var.:
10. Leaching minimum 150 ft from drinking we11'25 ft irrigation well Var.:
11. Tank/leaching minimum 10 ft from property line Var.: -
12. System meets all other setback requirements Var.: 7,
13. Uses adjustment for maximum high groundwater Var.:14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: 7
15. System not in top or subsoil(A,B horizons)or 5' removal 7
16. Proposed contours are suitable - 7
17. System meets slope requirements-min- 1/8", 1,4"preferred _ 4�
18. System meets breakout requirements PVC liner: Wall: I 1
19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel
21. No garbage disposal i
22. System adequately sized for its intended use
23. Minimum 6"stone or compacted below tank and dbox 47.
24. Manhole covers within 6"of grade, pump chamber cover to grade V
25. Inspection port on plastic chambers/leach field
26. Electrical permit for pump chamber/Separate meter for duplexes i/,,'
27. Pump system-2"line,weep hole,check valve, tee in dbox, pump size
28. Se tic tank/pump chamber to be factory waterproofed f :,
29. Vent provided if leaching below 3 feet,under driveway/parking
30. Buoyancy calculations for tank/pump chamber _.. -_-
31. Engineer to inspect and certify soils: wall: . commercial: o�
32. Engineer.:Registered Sanitarian and Land Surveyor stamps/signature j
33. H-20 loading is subject to vehicular traffic, groundwater C
34. Title V Application and permit fee, installer signature / 1
35. Foundation footing min. 2 feet above adjusted ground water for new house i #/
36. Deed Restriction required max. #bedrooms: max. flow: gpd I ✓ /
37. Check area lots for groundwater/Label groundwater in Assessor's Map ' I7
,
Plan reviewed by: ✓✓
3 - 2