Loading...
HomeMy WebLinkAbout4982 438 Route 6A Site PlanTOP SLAB EL. 33.5' 30.0' HOUSE 28.87' ' *EXIST. EXIST. 2000 GAL " BARN/APT TEE SEPTIC TANK** TEE *29.18t GAS BAF 4' LIQ. LEVEL (ACME OR EQL LEGEN D 99 - EXISTING CONTOUR x 99.1 EXIST. SPOT ELEV. -[99]-"" PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 TEST HOLE SLOPE OF GROUND C-OL) UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWM SYSTEM PROFILE ALL SYSTEM WITH COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2" PEASTONE OR GEOTEXTILE CONCRETE COVERS TO WITHIN 3" GRADE FILTER FABRIC OVER STONE MINIMUM .75' OF COVER OVER PRECAST 2x SLOPE REQUIRED OVER SYSTEM 29.0 -29.5 NOTE. 2" AWN. WALL BLOCKS OR THICKNESS REQUIRED PRECAST RISERS PRECAST H-10 4"0SCH40 PVC MORTAR ALL INVERT IN 25.67' RISWATERTEST ESS PIPES LEVEL 1ST 2' COMPONENTS _ 2 FOR LEVELNES5 ENDS (om') SIDES O OCOc 000000�0°°Sp�t O O O°O 10" 1000 GAL. H-10 14" q��ppppgq °o°g°o< 'TEE SEPTIC TANK TEE e\2_7.16 0 0 0 0 0 0 6" MIN. SUMP .. 0 0 0 0 e ;000ppoo° o p o o< °oo�a�000^Qo 12" MIN. TNT. DIM. 00000000 °°OHO°O°` 27.41 popop°°° popo°opg< V/V BAFFLE 00p°p°00< O O O O Op°p°p°p 26.16' 25.99' 4' UQ. LEVEL (ACME OR EQUAL) •' ` .•� a^ = • •R -':• • • •_ ' ': _ L H-10 500 GAL, LEACHING CHAMBERS BY ACME PRECAST OR o°00000c000coe0000000000°e0000e0000eon00000000go 3/4*-1-1/2" DOUBLE WASHED STONE 4' MIN. (5) UNITS REQUIRED 0000000�0 0 0�0,000000000�0�0„0 0 0�000000m ALL AROUND PRECAST STRUCTURES 4 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 50.50' X 12.83, 1� COMPACTION. (15.221 [23) (2.2 x SLOPE) MIN. t 2'4 x SLOPE) (_.5 _X SLOPE) (1.5 x SLOPE) BARN/APT. -- 64' EXIST. 5' SEPTIC TANK 20' D' BOX 24' LEACHING 19.0' BOTTOM TH-1 SEPTIC TANK ACILITYNO GROUNDWATER FOUND HOUSE - EXIST. (2000 GAL**) NOTES ZONING SUMMARY ZONING DISTRICT: R-40 RESIDENTIAL DISTRICT *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM I EXIST. PROP. MIN. LOT SIZE 40,000 S.F. 24,813 S.F. 24.813 S.F. MIN. LOT FRONTAGE 150' 101.89, 101.89, j MIN. FRONT SETBACK 30' 49.4' 49.4' MIN. SIDE SETBACK 20' 14.2' 14.2' MIN. REAR SETBACK 20' >50' 24.3' MAX. BUILDING COVERAGE 25% 9.9% 13.1% TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: PHIL RENAUD DATE: 2/24/22 PERC. RATE _ < 2 MIN/INCH CLASS I� SOILS ELEV. ELEV. O„ 30.0' 0" 4 30.2' A A LS LS 995 1OYR 3/3 9" 1OYR 3/3 B B LS LS 1OYR 5/8 1OYR 5/8 32" 27.33' 32" 27.53' PERC C I I C MS 2.5Y 7/6 2.5Y 7/6 132" 19.0' 132" NO GROUNDWATER ENCOUNTERED LICE ## 15-386 19.2' **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT 2000 GALLONS AND ITS SUITABILITY FOR RE -USE. REPLACE WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE 6A _ MAIN STREE T LOCUS MAP SCALE 1 "=2000't 1. DATUM IS NAVD 88 ASSESSORS MAP 123 PARCEL 63 2. MUNICIPAL WATER IS EXISTING, LOCUS IS WITHIN FEMA FLOOD ZONE X (PROPOSED FOR BARN) 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. SYSTEM DESIGN. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-M GARBAGE DISPOSER IS NOT ALLOWED 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE EXISTING 5 BR DWELLING WITH 310 CMR 15.000 (TITLE 5.) PROPOSED GARAGE W/ APARTMENT ABOVE (1 BEDROOM) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY DESIGN FLOW: 6 BEDROOMS ®110 GPD = 660 GPD - OTHER PURPOSE. USE A 660 GPD DESIGN FLOW 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. SEPTIC TANK: 660 GPD (2) = 1320 (FIRST COMPARTMENT) 9. COMPONENTS NOT TO BE BACKFILLED OR SEPTIC TANK: 660 GPD (1) = 660(SECOND COMPARTMENT) CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD TOTAL REQUIRED = 1980 GPD OF HEALTH. **RE -USE EXISTING 2000 GAL. SEPTIC TANK 10. CONTRACTOR SHALL BE RESPONSIBLE FOR ADD A 1000 GAL. SEPTIC TANK IN SERIES CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF LEACHING: WORK. SIDES: 2 (50.5 + 12.83) 2 (.74) = 188 GPD 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE BOTTOM 50.5 x 12.83 (.74) = 479 GPD PROPOSED LEACHING FACILITY. TOTAL: 901 S.F. 667 GPD 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND USE (5) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE AL AROUND 13. OWNER'S ENGINEER TO PERFORM INSPECTIONS OF THE FINAL INSTALLATION. MINIMUM OF 24 HOURS NOTICE REQUIRED. 14. EXISTING SEPTIC SYSTEM IS SHOWN BASED ON THE ASBUILT ON FILE AT THE HEALTH DEPARTMENT. MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 438 MAIN STREET (RT. 6A) YARMOUTH PORT, MA PREPARED FOR ALLISON BAILEY JOSEPH AUDETTE � A0�Mgssq ���HOFMgss9DATE: MAY 25, 2022 cy Scale: 1"= 20' DANIEI_ DANIELA. GN �s� ��o OJALA A' CIVIL " 0 10 20 30 40 50 FEET C?Jri�LA No.46502 o0 40080P P0��FG�STEa�`o�'`� off 508-362-4541 lq�0 SUR 1E� �SS1ONAL tiNG\ I fox d0 nOCope.com880 p down cope engi�eerin,f, Inc. 4 civil engineers r land surveyors 939 Main Street ( Rte 6A) DATE DANIEL A. OJALA, P.E., P.L. . YARMOUTHPORT MA 02675 15-386 BAILEY.DWG