HomeMy WebLinkAbout4983 45 Cedar St Site Plan Left and RightGRADE �N51 2% SLO FILTER FABRIC 9.5 TOP 8.74' FINISHE JE ACCESS COVERS TO WITHIN 6" OF FIN. GRADE TOP OF FNDN EL. 9.9' ACCESS COVERS TO GRADE 9.5' MINIMUM .75' OF COVER OVER PRECAST PRECAST H-10 WATERTEST D'BOX Rzs�Rs {TYP.) FOR LEVELNESS 7.9'f 2500 GAL H-10 10" SEPTIC TANK/ 7.23' TEE PUMP CHAMBER COMBINATION 5' LIQ. LEVEL (ACME OR El 4"OSCH40 PVC PIPES LEVEL 1 ST 2' SEE DETAIL BELOW 13 8.62' 8.45' 1.48' ;..:.:: ..:•;. 6" MIN. SUMP 12" MIN. INT. DIM. pappa°a°p°oaapappdoaoao°ppo°OaoaoaopppoPa°°pp 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) (2.5 SLOPE) (1 % SLOPE) ( 1 % SLOPE) FACTORY WATERPROOFED FOUNDATION— 27' SEPTIC TANK 5' D' BOX 6' — *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND - 99 — EXISTING CONTOUR X 99. r EXIST. SPOT ELEV_ —[991--~ PROPOSED CONTOUR [98.4] PROPOSED SPOT EL. TH1 TEST HOLE SLOPE OF GROUND 71) UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYM&XS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: MALLORY LANGLER DATE: 3/ 12/21 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS Q ELEV. 0�� 8.5' A LSle 10" 1OYR 3/1 B LS 1OYR 5/6 20" 6.8' PERC I ACCESS FOR ROUTINE MAINTENANCE MUST BE PROVIDED FOR ZABEL FILTER. INSTALLER MUST FOLLOW ALL MANUFACTURER'S SPECIFICATIONS FOR PROPER FILTER INSTALLATION 8.39" CLEAN FILL 4" PERFORATED PVC 3' O.C, S 3/4"-1-1/2" DOUBLE WA 8' STONE LEACHING FIELD LEVFL 3 D. 0' LEACHING FACILITY ALARM AND CONTROL PANEL TO BE INSTALLED INSIDE BUILDING. ALARM TO BE ON INV. IN 7.23' SEPARATE CIRCUIT FROM PUMP ZABEL FILTER FLOAT SWITCH ALARM ON CUTLET TEE W/EXTENSION SETTINGS: PUMP 1ON:Z�q 5" WORKING RANGE 6 5" PUMP OFF 12" MS GROUNDWATER ADJ. DATA: WELL: MIW 29 a 2.5Y 7/6 ZONE: A ADJUSTMENT: 1.74' (MARCH) 120" GROUNDWATER ENCOUNTERED AT 78" EL. 2.0 I)CF. U21--- 0,S0 ACCESS COVERS TO GRADE 19" TEE 1500 GAL. MIN. THIS SIDE OF BAFFLE 6.8, PF v \--- 6" BAFFLE FACTORY WATERPROOFED 2500 GAL. SEPTIC TANK/PUMP CHAMBER c (NOT TO SCALE) o 0 R STpEET C� A Scale: 1' = 20' f 0 10 20 30 40 5C FEET S8�7 FW c nw SPEC"ON 0 1_� 29.7 PROPC ADDITI (SLAB NVK I `5LL Ut I AIL) 4" LOAM & SEED ADJUSTED GROUNDWATER EL. 2.74 }DICK DISCONNECT FOR PUMP 600t GAL. RESERVE /IDED IN PC 3SURE LINE -0 DRAIN BACK _ES ALVE =RS SRM 4 ERSIBLE 4/10 HP PUMP EM (OR EQUAL) 3LOCK) 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 'TH MIN. BELOW INV. 7 THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING VERIFYING ITHE FLOCATION OF ALL UNDERGROUND & LOCUS MAP OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. SCALE 1 "=2000'f 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL ASSESSORS MAP 34 PARCEL 126 BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. LOCUS IS WITHIN FEMA FLOOD ZONE AP* EL 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 13. ACCESS FOR ROUTINE MAINTENANCE MUST BE PROVIDED FOR ZABEL FILTER. INSTALLER MUST FOLLOW MANUFACTURER'S SPECIFICATIONS FOR PROPER FILTER INSTALLATION, INSTRUCT OWNER ON MAINTENANCE. 14. INSTALLER TO VERIFY THE ELECTRICAL SYSTEM IS SUITABLE FOR PUMP CONNECTION PRIOR TO ORDERING PUMPS. ELECTRICAL PERMIT REQUIRED. 15. FEMA FLOOD RESISTANT FOUNDATION DESIGN AND COMPLIANT GRADING REQUIRED. DESIGN BY OTHERS. 16. GUTTERS AND DOWNSPOUTS TO BE DIRECTED TO DRYWELLS OR ROOF DRIP LINES TO STONE TRENCHES. 17. ENGINEER TO INSPECT AND CERTIFY SYSTEM. 11 AS SHOWN ON COMMUNITY PANEL #25001 CO589J DATED 7/16/2014 VARIANCES REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1b): REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 10.2') UNDER TOWN OF YARMOUTH HEALTH REGULATIONS: REDUCTION IN GROUNDWATER ADJUSTMENT: USE 0.74' OF THE MARCH 1.74' ADJUSTMENT MINIMUM 24 HOURS NOTICE REQUIRED. NATION ZONING SUMMARY SYSTEM DESIGN: ZONING DISTRICT: R-25 RESIDENTIAL DISTRICT MIN. LOT SIZE 25,000 S.F. GARBAGE DISPOSER IS NOT ALLOWED MIN. LOT FRONTAGE 150' DESIGN FLOW: 3 BEDROOMS Q 110 GPD = 330 GPD MIN. FRONT SETBACK 30' MIN. SIDE SETBACK 15' USE A 330 GPD DESIGN FLOW MIN. REAR SETBACK 20' SEPTIC TANK: 330 GPD (2) = 660 MAX. BUILDING COVERAGE 25% USE A 2500 GAL. H-10 DUAL COMPARTMENT PROPOSED BUILDING COVERAGE 21.9% SEPTIC TANK/PUMP CHAMBER LEACHING: z� BUOYANCY CALCS: 330 GPD (.74) = 446 SF REQUIRED (7 H-10 2500 GAL. ST/PC WEIGHS 24,000 LBS 15' X 30' = 450 SF OK 6.5' x 12.0' x 2.26' x 62.4 = 11,000 LBS UP (OK) 450 SF X .74 = 333 GPD OK USE A 15' X 30' PIPE AND STONE LEACHING FIELD v APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF PROVIDE 46' OF 40 MIL LINER AT 5' 45 CEDAR STREET OFF SAS IN AREA SHOWN. TOP AT SOUTH Y A R M O U T H, M A � ELEV. 8.8', BOTTOM AT EL. 4.8't PREPARED FOR tHOF'NAS,r_ .s�ZHiFMa�- o DANIEL cyG� god DANIEL A, A. OJALA -4 o OJALA �n A CIVIL >. No. 40 No. 46502 L(REQUIRE u `FACILITY PLA :T 255( MA EYER & SONS BUILDERS, INC. 0: AANIc;`L A. mo 4650 �1?r ni.a eill DATE DANIEL A. OJALA, P.E., .L.S. DATE: JULY 22, 2021 a__REV: SEPTEMBER 16, 2021 (HEALTH COMMENTS) off 508-362-4541 fax 508-362-9880 downcope.com C dowa cope engiftetvh4f, i7, C. civil engineers land surveyors 939 Maui Street ( Rte 6A) YARMOUTHPORT MA 02675 21--050 MEYER & SONS BLDRS.DWG