HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. 3.g Lot Zone of Contribution: In Out ''Acreage
Commercial: Residential: j,-_„--_
Street: 7 Adcl.
Village: Floor Plan: fr- #Bedrooms: 3
Owner: /` o r L RG `CSc� Installer: Se at C cs wN P d eg
Address: Phone:
Phone:
Builder: Engineer: D. q,S v IL.J
Address: Phone:
Phone:
N.A YES I NO
V
1. Required# of copies received
2. Date of soils exam and percolation test not older than 2 years
3. 4-5 ft of naturally occurring pervious material, above water table _
_ 4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: IZ__
5. Water line 10 ft from septic components Var.: -
6. Benchmark indicated and shown-NGVD if near wetlands ,/'
7. Septic tank minimum 10 ft from foundation, deck Var.: "
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9. Leaching minimum 100 ft from wetlands Var.: I V
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: j
11. Tank/leaching minimum 10 ft from property line Var.: I
12. System meets all other setback requirements Var.:
13. Uses adjustment for maximum high groundwater Var.:
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: ✓
15. System not in top or subsoil(A,B horizons)or 5' removal _1 I j •*
16. Proposed contours are suitable ✓
17. System meets slope requirements-min. 1/8", `,!"preferred v
18. System meets breakout requirements PVC liner: Nall: I -
19. Specified tee sizes are proper, gas baffle on outlet tee 1 1.//
20. Sewage is under 10,000 gpd for parcel
21. No garbage disposal
22. System adequately sized for its intended use
23. Minimum 6"stone or compacted below tank and dbox I
f 24. Manhole covers within 6"of grade, pump chamber cover to grade
IV
25. Inspection port on plastic chambers/leach field i .
26. Electrical permit for pump chamber/Separate meter for duplexes
27. Pump system-2"line,weep hole,check valve, tee in dbox,pump size
28. Se tic tank/pump chamber to be factory waterproofed
29. Vent provided if leaching below 3 feet,under driveway/parking
30. Buoyancy calculations for tank'pump chamber
31. Engineer to inspect and certify soils: wall: commercial:
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature j /
33. H-20 loading is subject to vehicular traffic, groundwater I L.../
34.Title V Application and permit fee, installer signature i
35. Foundation footing min. 2 feet above adjusted ground water for new house i
36. Deed Restriction required max. #bedrooms: max. flow: gpd I 7
37. Check area lots for groundwater/Label groundwater in Assessor's Map
7" . ,
Plan reviewed by: te a' ___ 60 01
9-dG - a Z