Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. 3.g Lot Zone of Contribution: In Out ''Acreage Commercial: Residential: j,-_„--_ Street: 7 Adcl. Village: Floor Plan: fr- #Bedrooms: 3 Owner: /` o r L RG `CSc� Installer: Se at C cs wN P d eg Address: Phone: Phone: Builder: Engineer: D. q,S v IL.J Address: Phone: Phone: N.A YES I NO V 1. Required# of copies received 2. Date of soils exam and percolation test not older than 2 years 3. 4-5 ft of naturally occurring pervious material, above water table _ _ 4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: IZ__ 5. Water line 10 ft from septic components Var.: - 6. Benchmark indicated and shown-NGVD if near wetlands ,/' 7. Septic tank minimum 10 ft from foundation, deck Var.: " 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9. Leaching minimum 100 ft from wetlands Var.: I V 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: j 11. Tank/leaching minimum 10 ft from property line Var.: I 12. System meets all other setback requirements Var.: 13. Uses adjustment for maximum high groundwater Var.: 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: ✓ 15. System not in top or subsoil(A,B horizons)or 5' removal _1 I j •* 16. Proposed contours are suitable ✓ 17. System meets slope requirements-min. 1/8", `,!"preferred v 18. System meets breakout requirements PVC liner: Nall: I - 19. Specified tee sizes are proper, gas baffle on outlet tee 1 1.// 20. Sewage is under 10,000 gpd for parcel 21. No garbage disposal 22. System adequately sized for its intended use 23. Minimum 6"stone or compacted below tank and dbox I f 24. Manhole covers within 6"of grade, pump chamber cover to grade IV 25. Inspection port on plastic chambers/leach field i . 26. Electrical permit for pump chamber/Separate meter for duplexes 27. Pump system-2"line,weep hole,check valve, tee in dbox,pump size 28. Se tic tank/pump chamber to be factory waterproofed 29. Vent provided if leaching below 3 feet,under driveway/parking 30. Buoyancy calculations for tank'pump chamber 31. Engineer to inspect and certify soils: wall: commercial: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature j / 33. H-20 loading is subject to vehicular traffic, groundwater I L.../ 34.Title V Application and permit fee, installer signature i 35. Foundation footing min. 2 feet above adjusted ground water for new house i 36. Deed Restriction required max. #bedrooms: max. flow: gpd I 7 37. Check area lots for groundwater/Label groundwater in Assessor's Map 7" . , Plan reviewed by: te a' ___ 60 01 9-dG - a Z