Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
22-A119 39 Mariners Lane
RECEIVED TOWN OF YARMOUTH 1146 ROUTE 28. SOUTH YARMOUTH: MA 02664-4451 SE P 2 9 2022 Telephone (508) 398-2231 Ext. 1292—Fax (508) 398-0836 ARN;;Q ,D KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE APPLICATION FOR CERTIFICATE OF APPROPRIATENESS Application is hereby made for issuance of a Certificate of Appropriateness under Section 6 of Chapter 470, Acts of 1973 as amended, for proposed work as described below & on plans, drawings, photographs, & other supplemental info accompanying this application. PLEASE SUBMIT 4 Conies OF SPEC SHEET(5), ELEVATIONS PHOTOS, & SUPPLEMENTAL INFORMATION. Check All Cate cries That A l indicate type of Building: Commercial X Residential 1) Exterior BuilMSolarPanels Construction:"Other: New Building Addition Iterations I_JReroof ,Shed 2) Exterior Painting: 7Siding Shutters II Doors Drim ,other: 3) Signs/Billboards: O New Si n Change to Existing Sign 4) Miscellaneous Structures: Fence Wall Flagpole IIPool IlOther: Please type or print legibly: r J Address of proposed work: 39 Mariners Lane Yarmouth MA Map/Lot # Owner(s): Patricia Mechlinski Phone #.774-254-4493 All applications must be submitted by owner or accompanied by letter from owner approving submittal of application. 'IQ Marinprc I nnp Ynrmni ith MA I a-7'1 Mailing address: Email: PatMech@comcast.net Agent/contractoc Beacon Solar/ Phil McCarron Year built ' V ! " Preferred notification method: Phone Email Phone #: 401-203-4854 Mailing Address: 2 Shaylee Lane, Lakeville MA Email: permits@beaconsolarma.com Preferred notification method: Phone _Email DescriptionProposed Work: o ro ose, installation of 25 Solar PV modules on existing roof. Very little visibility from street. Please see pictures Signed (Owner or agent): �L t Date. 9/26/2022 Ownerlcontractorlagent is aware that a permit is required from the Building Department (Check other departments. also.) It applica€ion is approved, approval is subject to a 10-day appeal period required by the Act. This certificate is good for one year from approval date or upon date of expiration of Building Permit, whichever date shall be later r All new construction will be subject to inspection by OKH. OKH-approved plans MUST be available on -site for framing 8 final Inspections. Rcvd Date: q l.>1 22 Amount W. Cash/CK #: Rcvd by: L 5, 45 Days: Date Signed: Approved Approved with Modifications Reason for Denial: Signed. Denied APPLICATION #: ;P- , 1 GENERAL SPECIFICATION SHEET Proiect Address: FOUNDATION: Material: Exposure (Not to exceed 18'): CHIMNEY: Material/Color: GUTTERS: Material/Color: ROOF: Material: Pitch (7/12 min) Height to Ridge: Color: SIDING: Material/Style: Front: Sides/Rear: COLOR CHIPS Coior. Front SideslRear: TRIM: All windows & doors to be trimmed with: 1x 4 1x5 (Circle one.) Material: Color: DOORS: Qty: Material: Color RECEIVED Style/Size (if not listedlshown on elevations): SEP s�� 2 s Zozz STORM DOORS: Qty Material: Color: YARVIUU-i_h GARAGE DOORS: Qty: MatT Style: Color: OLD KINC WINDOWS: Qty/side:: Front Left: Right: Rear: Color: ManufacturerlSeries: Material: Grilles (Required):._ Pattern (616. 211, etc.) Snap -In: — Between Glass: Permanently Grille Tyre: True Divided Lite: Applied: Exterior Interior STORM WINDOWS: Qty: Material: Color: SHUTTERS: Mat'I: Style: Paneled Louvered Color: SKYLIGHTS: Qty: Fixed Vented Size Color: DECK: Size: Decking MatT Color: Railing MatT Style: Color: WALLS/FENCES'` (Max 6' height): Height: Mat'I: Style: Color: (Show running footage & location on plot plan.) 'Finished side of fence must face out from fenced in area. UTILITY METERS/HVAC UNITS: Location: Screening: LIGHTS: Qty: Style: Color: Location(s): LIGHT POSTS: Qty: Material: Color: Location(s): Additional information: 25 Solar PV Modules - Longi Green Energy Spec Sheet attached 2-General 2;1 1 APPLICATION #: 1 1� TOWN OF YARMOUTH 1146 ROUTE 28, SOUTH YARMOUTH, MASSACHUSETTS 02664-4451 Telephone (508) 398-2231 Ext. 1292 Fax (508) 39"836 OLD KING'S HIGHWAY HISTORIC DISTRICT COMNUTTEE WAIVER OF 45-DAY DETERMINATION The applicant/applicant's agent understands and agrees that due tQ the current declared National and State public health emergencies the determination of our Application for a Certificate of Appropriateness/Demolition/Exemption may not be made within 45 days of the filing of such application. The applicant agrees to extend the time frame within which a determination is to be made as required by the Old King's Highway Regional Historic District Act. SECTION 9 -Meetings, Hearings, Time for Making Determinations "As soon as convenient after such public hearing; but in any event within forly 've (4.5) clays after lhe_iling of application, or within such further time as the applicant shall allow in writing, the Committee shall make a determination on the application. " Applicant understands that the review of this application will be scheduled as soon as the situation allows. Applicant/Agent Name (please . ): Phillip McCarron Applicant/Agent signature: Date: EIV ED SPP 2 9 2022 Y P Rjv;ou,� r 9/26/2022 Application #: W2020 TOWN OF YARMOUTH OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE ABUTTERS' LIST Patricia Mechlinski Applicant's (Owner) Name: Property Address/Location- 39 Mariners Lane Yarmouth MA Hearing Date:_ Notices must be sent to the Applicant and abutters (including owners of land on any public or private street or way) who's property directly abuts or is across the street from the Applicant. Please provide the Assessor's Tax Map and Lot numbers only. The OKH Office will send out notices using the addresses as they appear on the most recent applicable tax list. Note: Instructions for obtaining the abutters Map and Lot numbers can be found on the Old Kings Highway Department page on the Town website: www.yarmouth.ma.us Map Number Lot Number Applicant Information: 1 q Q {p Abutter Information: RECEIVEO SEP 2 9 2022 YARIytOUTh Application #: , ;P-AAlq 9.2018 3 9129122, 11:09 AM 39 Mariners Lane 140.24 1140.191 140.23 j 140.22 Seplembef 29. 2022 140.29T 14o?58C 19' 1-41.17 141�18 ,� ■ i l41.19 140.2&.1 I1l,40.59 141�20 140.28.11 140.62 _'W 41.21 1�22 1411IN3 � 140.26 140�7 140.60 1410121 SUS qR� l41.23 � 140.61 �, KE` cH LANE ,+ 141.3 • 141�10 4 - - - �iAN 1y1� ' 14i.5 141.E 1*4 67 * �465 � �141.6 140.66 14i.2 133.22 141.1 9 • 132:9133.26 13t 2.(i00 1` 3r� 124.68 132,9711 _ 1'33!24 BELVEDERE TRr� 133.27 �Qc� 1t8 �33.23 13284 r 132sr�ir 133' 2.95 132.108 o �, A3330 � 133.9 1 `� 133.31 132.94.1 132T110 6 � 133.21 r EC:EI'VED SEP 2 9 2022 YARIV,OU [_h_, 1 2257 0 75 I K 300 ft 1 - , I , , i . ..ITT 0 20 40 80 m Hm.. EFd. A:-bua 7. USCS. %G�. Nk�. 4cA9 4 -Wn— 1418, GSA rWYC FEW nsrw ara ne c's �wwrrr rr arm �v a,:a,e sn:an an W6 +a; a"a P-tw rx xal,.ig am --nIa .—Ko, E4-'ac,uay, �,-a —AO 9115122, 11:10 AM 39 Mariners Ln - Google Maps 39 Mariners Ln Front of House - No Panel Visibility RECEIVED SEP 2 9 2022 Y Artiiwvv 1_1 .... _ . );>-,fly htips://www.g oogle. com/maps/place/39+Mariners+Ln,+Yarmouth+PorL,+MA+026751@41.7131894,-70.2317593,3a,75y, 97.95h, 99.97Udata=!3m6! 1 e i !... 112 p ƒ: ECE|VED SEP 2 2 2022 YAhl 2 &;d KINGS RGH&a¥ y. y�y�z ECE[VE®. s E P 2 9 2022 YARMOU1 H Qmm� a L U N N L 4-1 C L cu L.L - s � � � I U) O L ��IIAy tt r.f 4.�.„v fs.•,+, 9 y � ^ % 111Yif� ECEIVED SEP 2 9 2022 YARMOUTv, p j. )II I —,,Wyk l b AIX 1 Y f 1• t: s 1 , t w r O M $ T N QU N fn N N c n W d fwj Y a (7� auJa o �n Q o _ wZr c :5 O 2q r I N d wU j!, C �w� o � LLI (LN w = 2' w� o Z� Y �a 9 w¢zra> } p U a y a U p w T = O—¢ N r¢ w z�o r ff— v ,L w� z n N vn w w y c3 Q RECEIVED c=i a M� � a 0 n a O w a � w¢ r ¢ V) � 2 o � SEP 2 9 2022 OLD KINGS HIGHWAY ,v ca b I1 Q } 4 a A � a Q � 1 } Q � K a z n z � to z w f iu a ��_ iE N7 SZf3iY12lNW 6 w J Q U z 3 a w Ni Complete System and Product Certifications IFC 6121S, IFC 6i:3{}, JE 61730 so 9o01:2008. ISo Qualify wnagement Systen iso 14001: nw: Aso Enviranment Management System TS62941: Guideline for moduie design qualification and type apprava€ oHSAS IS001: 20070Ccupati0nal Health and Safety Specifications UMG] Sala, csc NGI Positive power tolerance i© -+5W) guaranteed High module conversion efficiency (up to 20.30A) Slower power degradation enabled by Low L€D Mono PERC technology: first year <2%, 0."55%Lear 2-2S Solid PID resistance ensured by solar celf process optimization and careful module ROM selection Reduced resistive loss with lower operating current Higher energy yield with tower operating temperature Reduced hot spot risk with optimized electrical design and to er 4 t/ WF—D SEP 2 9 �' YAmfV1Vu t I . Room 801, Tower 3, Lujiazu€ Financiat Plaza, No.826 Century Avenue. Pudong Shanghai. 2,30120, China Tel: +36-21-50162606 E-mail: module@Iongi-silicon.mm Facebook: ww%facebook,com/LONGI Solar Note: Due to continuous technical innovation, R&D and improvement, technical data above mentioned may be of modification accordingly. LONG have the sole right to make such modification at anytime without turther notice; Demanding pam, shaft request for the latest datasheet for such as contract need, and make it a consisting and Binding part of ia,wful documentation duly signed by both parties. ' 70200401Y11 RIIIIII4•i Pi i 11�I]esign (mm} Mechanical Parametjjiers Operating IIIIIIIIIIIII Pilillill IIIarameters Cell Orierliatfan:120{6x20) Operational Temperature: -40 )unction Box:IP58, three bodes Power OutputTderance: D `+5 W 9 Output Cable: 4!rn1', 305nm in fer$th, Voc and Isc Tolerance: *39. fengJ; can he nlstom2ed Maximum System Voltage: DCIODGV (1EQUL) Glass:5ngieglass Maximum SefiesFuse Rating: 20A 3.2mmcoated temperedglass Nominal Operating Cell Temperature:451C: kn Frame:Anodized aEuminumalloy, fiame Weight:19.5kg Safety j 'r '������ U.1rent�r61 Fo. Toren"«: Dimension:1755x1038x35mm Packaging: Konsper pa''- (+ C p �jn SEet 2 9 2022 ?1d .+...._ ISOper 20 7&T1per 40•HC YAR(Viou-( r-i Model dumber ft4-COHPB-345s", _R6-60HP$-35ON'. .113-60HPB-355M LR4-60H,^B-360b1 LR4-60HPB-365M LI?d-GOH99-3700 NGCT STC \GC', 5_c NL',- STC NOCT STC NO ....: NOCT i?axinldrr';'o::er(Pmax1W) 345 257,fi 350 261..4 355 265.1 360 268.8 365 272.6 370 276.3 open Circuit'.oita,ge (VGc!V) 40.2 37.'• 40.4 37.9 405 33.1 40.3 35.3 -'- 0 33_e ------ Short Vucu,t C' rreni (IsC/A) 11 Do - 4.9�a :. 11.16 9.02 11.25 °.DQ 11.33 9.16 Ii.41 9.23 s - .0 930 VGI?a 3.2 34.8 32. i.t 2 32 8 Current at Maximum Power (ImpjA) 1009 8.09 10AS 8 ib 10.27 8.23 FO 35 3.30 10.43 8.30 .C.52 SA3 Modtlte Efficiency(',,) ---------- - ------ 18,4 ------- 19.' ............... i55 19.F. ... _...---------'----._ 20.0 ................-- STC (Standard Testing Cor;ditions): Irradiance 1000Vd%m', Call Temperature 25 C, Spectra at AM1.5 NOCT (Nominal Operating Cell Temperature): Irradiance 800W/3n=, Ambient Temperature 20 C, Spectra at AM1.5, Wind at 1m/5 Temperature Coefficient of Isc +0.048%i C Temperature Coefficient of Voc -0.270V t' Temperature Coefficient of Pmax -0.35045/C Current -Voltage Curve (LR4.60HPB•360M) 12 10 i„tae�u..w =ttxtmWm° a -CeIIT p=ZSC Q c 6 -CeIIT p=3sC -CeIIT prSC -[cIIT p=55C V 4 ---CeIIT p-65C -Cell lemp•l5C 2 0 0 10 20 30 40 50 voltage (v) NG1 Front Side Maximum Static Loading Rear Side Maximum Static Loading Hailstone Test Power -Voltage Curve (LR4-60HPB-360M) 4DO CNi temp-25C. 35n tl>7o�lm' 300 - 60exlm' 250 - 00/m' 2n0 a 150 100 50 0 0 10 20 30 40 50 voltage [v) 5400Pa 240OPa 25mm Hailstone at the speed of 23m,/s Current -Voltage Curve (LR4-60HPB-36DM) 12 10 4 c 6 u 4 2 0 a 10 20 30 40 voltage I 50 Roam 801, Tower 3, Lu)iazui Financial Plaza, No,826 Century Avenue. Pudong Shanghai. 200120, China Tel; +36-21-80162606 E-mail: module@longi-silicon.co!n Facebcok: www,facebook.cnm/LONGI Solar Note: Due to continuous technical innovadon, R&D and improvement, technical data above mentioned may be of modification accordingly. LONGI have the sole right to make such modifitatfon at anytime without further notice; Demanding party shall request for the latest datasheet for such as contract need, and make it a consisting and hinding part of lawful document.1don di ly signed by both parties. ?fl2t?p40t1. `.