HomeMy WebLinkAboutEngineer PlanLEGEND A, N 617) x 100.98 EXISTING SPOT GRADE 0 JLI�� y --10-- EXISTING CONTOUR PROPOSED SA.S f o 22 —W— EXISTING WATER SERVICE oy .. " 3 ROWS OF 3 CULTEC HEALTH DEPT. EXISTING GAS SERVICE C4 HD FIELD DRAN UNITS .-�H-.-- OVERHEAD WIRES TEST PIT STRIPOUT BOUNDARY eJ (SEE NOTE 11) $ BENCHMARK PROPOSED 15 0/500 GALLON gg EXISTING SEPTIC TANK SEPTIC TANK/ UMP CHAMBER PUMP. RUPTURE, FILL w/sAND o Yarmouth Health Department PPROVED EXISTING S.A.S. (approx.) �g 2'15 E x a /9�4 24, r 2 LOCUS MAP ro BE LOCATED, PUMPED, EirrED N 3 p - 1''_ 8 �.a6 ame DateG NERAL NOTES: WITH SAND AND ABANDONED ' 15 r-- - '". — $ {N`. 1 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL B UL E S •+ x t' PR --'' , ®j1-Id ® BOARD OF HEALTH AND THE DESIGN ENGINEER. 97 22 U 979 9856 F9g..' �,.�2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS .} OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE I.. 98�8.— 98.29 LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: —310 CMR 15.405(1)(b)&(h): LOCAL UPGRADE APPROVAL 97.65 + 97' x� duo x 9g 39 N x m 1) An 8' variance, S.A.S. to cellar wall, for a 12' setback. `n/ ` 99 27 x 9912 o t\...�` 2) A -1' reduction to. the 5' separation requirement between estimated C, ♦ >>_ m I high groundwater and bottom of S.A.S. for 4' of separation. •O 3. THE SEWAGE DISPOSAL SYSTEM SHALL NO f BE BACKFILLED PRIOR LOT 62 �� B95 � F mac' ` x O O � TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE 15,100tS.F. A92 98.98x• O DESIGN ENGINEER. 98.46 Q 10004 `V O 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING `w 9698+ {+ 98 2 `9 A90"'"�`> �\ o FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN r \\ ENGINEER BEFORE CONSTRUCTION CONTINUES. \ BH EXISTING a o x m I �\ 5. ALL ELEVATIONS BASED ON AN ASSUMED DATUM. 991 ?x, url1 pzrt'49 71 I �t �./ E FAILURE OF WW� 9553 L OF Mgss9c PETER T. 9� McENTEE CIVIL No, 35109 1 1 + 9648 551 SPIKE L� \ -z_ cs 94.81 WL 11 9463 EL=99.92 VVHLn 1 1\ DECK � x 1 x 9837 98,76 � �1 1 0 x 97,39 r9, 92 99 68 m� 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR TH THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF IT) Z� HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 9UL0£ 98.52 1 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. yW 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. u 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS ox AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE gg,pg 98,61 DIRECTED BY THE APPROVING AUTHORITIES. r 8 5 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ��'vW THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. it. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND. 98,76 REPLACE WITH CLEAN SAND AS SPECIFIED IN.. 310 CMR 255(3). x 9996 12, AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. BENCHMARK 2 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND MAG. NAIL SET 0.00 NOT CONSIDERED TO BE A PROPERTY LINE SURVEY. EL.=98.61 LE 14, THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC SYSTEM COMPONENTS NOT SHOWN ON THE PLAN. 15, THE PROPERTY LIES WITHIN A STATE REGULATED ZONE IL MAP ID: 115-96 PROPOSED SEPTIC SYSTEM UPGRADE PLAN 57 ARROWHEAD DRIVE, YARMOUTH PORT, MA Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 02673 OWNER OE RECORD Engineers: Surveyors: SCALE DRAWN JOB. NO. JANEDY, NICHOLAS J TR CLARA (LIFE EST) En ineerin Works, Inc. 9 9 JCEn Engineering, Inc. g g' 1"=20' P.T.M. 277-22 JANEDY, 28 GIBBENS ST 12 West Crossfield Road Forestdole, MA 02644 2854 Cranberry Hwy. E.Wareham, MA 02538 DATE CHECKED SHEET NO. SOMERVILLE, MA 02143 (508) 477-5313 (508) 273-0377 9/3/22 P.T.M. 1 of 3 PROVIDE RISERS WITH APPROVED FRAMES & OVER EACH ACCESS MANHOLE AND SET TO GRADE. MANHOLES BROUGHT TO GRADE SHA SECURED TO PREVENT UNAUTHORIZED ACCE' .O.F =101.4f F.G. EL.-99.3t L =3 4"SCH40 INVERT =95.90 CONNECT TO EXISTING SEWER OUTLET -INV.=98.6t (verify) PROPOSED D-BOX INSTALL WATERTIGHT RISER & COVER SET TO 6" OF GRADE F.G. EL.-99.0t F.G. EL. 98.0t �P.OVIDE Ef 01 C4 WIRE r s ❑ L=8' MAXIM 0 2" SCH 40 PVC ® SCH (MIN.) TOP EL.=96.99 PROVA)tE ATLHRU`L,gE+TNDBLOCKS 4"SCH40 PVC 1 - e' s 3" TO INVER 0.1 and ascHMao avcE / STG. G.W. EL=so.91NV.=97.27 INV.=97.10 E ti iRTJ ADJ. G.W. G.W. . -92.6 PROPOSED D—BOX 2' (uaEu ore eouau 6 OUTLETS (MIN.) INV.=97.00 BOW. EL.=91.32 - H-10 INV.=95.9t INSTALL ONE LENGTH OF 4" SCH 40PERFO INV. 95.65 PIPE AT EACH INLET TO EXTEND THROUGH EFFLUENT FILTER SHALL BE INSTALLED ON OUTLET WITH CAPPED END. HOLES SHALL BE FACED TEE AS MANUFACTURED BY ZABEL OR 7QUAL. FILTER SHALL BE INSPECTED AND CLEANED A NUALLY, OR AS F.G., ELEV.=98.8t — REQUIRED TO AVOID SEWAGE BACK UP (See Pump Detail, Sheet 3 of 3) H-10 TANK NOTES: 1) SEPTIC TANK/PUMP CHAMBER & D—BOX SHALL BE SET LEVEL & TRUE TO GRADE ON A MECHANICALLY COMPACTE STABLE BASE, PER 310 CMR 15.221(2), 2) INSTALL INLET & OUTLET TEES AS REQUIRED. 3). MAX. COVER OVER TANK, D—BOX & S.A.S. SHALL BE 36". 4) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION. DESIGN CRITERIA NUMBER OF BEDROOMS: 3 BEDROOMS SOIL TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE: <6 MIN/IN DAILY FLOW: 330 G.P.D. DESIGN FLOW: 330 G.P.D. GARBAGE GRINDER: NO PROPOSED SEPTIC TANK/PUMP CHAMBER: 1500/500 PROPOSED DISTRIBUTION BOX: DB-6 (H-10) LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF ,70 GPD/SF BOTTOM AREA:(GENERAL USE APPROVAL FOR 6.7 SF/LF) 3 UNITS. x 8.0'/UNIT = 24.0 FT 3 ROWS x 24.0' x 6.7 SF/LF = 482.4 SF DESIGN FLOW PROVIDED: 0.70(482.4 S.F.) = 337.7 GPD TOP OF STONE ELEVV.=97.7t TORCH6��UEV=197.46- IN.ELEV.=97.00 - BOTTOM ELEV.=96.75r 4' OF NATURALLY OCCURRINI PERVIOUS MATERIAL 5' (MIN.) ABOVE G.W. ADJUSTED G.W., EL=92.6 SEPTIC SYSTEM PROFILE SOIL LOG DATE: AUGUST 18, 2022 SOIL EVALUATOR: PETER McENTEE SE#1542 WITNESS: JAY GARDINER HEALTH AGENT ELEV. TP DEPTH 98.6 � 0" FILL 96.8 1 � 22" NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL-97.5 PROPOSED S.A.S. FOR A DISTANCE OF 15' AROUND THE INSTALL ONE INSPECTION PORT (MIN.) PERIMETER OF THE S.A.S. fF.G. EL.=98.8 (MIN.) MAINTAIN 2% GRADE (MIN.) OVER SAS. INSPECTION PORT 3 ROWS OF 3—CULTEC C-4 UNITS x 8'/UNIT=24' (USE C-4 HD UNITS — H-20 RATED) i SOIL ABSORPTION SYSTEM (PROFILE) BI! PR D PVC ATI TER UNIT NNWARD. /` 4f OF LOAM &SEED OR APPROVED FILTER FABRIC T-9"t COMMON GRAVEL BACKFILL 48" (TYPICAL) I EXISTING SUITABLE SOILS 3 ROWS 0 3'/ROW(NO SPACE BETWEEN)=EFFECTIVE V 1" WASHED STONE PLACED TO 6"ABOVE FIELD DRAIN UNITS — EXTEND STONE FORI 2' OUTSIDE S.A.S. FOOTPRINT 0 Nt:�. SEA 19 2022 \ HEALTH DEPT. N R37 g3 rp a'�r 96.1 IUTK 4/z 301. B LOAMY SAND PERC STRIPOUT TO 10YR 5/8 20/40" SUITABLE " 8 . HORIZON 94.4 1 SO" CMED. SAND 2.5Y 6/4 92.6 ADJ. GW 72" REDOX 7.5 YR 5/8 90.9 STG. GW 92" 90— - 94" PERC RATE <2 MIN/IN. "B" HORIZON STANDING GW, EL.=90.9 ESTIMATED HIGH GW, EL.=92.6 (REDOX) S.A.S. LAYOUT PROPOSED SEPTIC SYSTEM UPGRADE PLAN 57 ARROWHEAD DRIVE, YARMOUTH PORT, MA Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 02673 Engineers: Surveyors: I SCALE DRAWN JOB. NO. Engineering Works, Inc. JC Engineering, Inc. N.TS. P.T.M. 277-22 12 West Crossfleld Road 2854 Cranberry H" Forestdale. MA 02644 EWarehom, MA 02538 DATE CHECKED SHEET NO. (508) 477-5313 (508) 273-0377 9/3/22 P.T.M. 2 of 3 PROVIDE WATERTIGHT CONCRETE SECURED FRAME & COVER TO C HOISTING CABLE 7x19 STAINLESS STEEL 1/8" DIAMETER. / 1,760 LB. STRENGTH. (TO BE INSTALLED IF QUICK DISCONNECT IS NOT INSTALLED) INV.(IN)=95.65 ALARM ON EL: 93.16 PUMP ON EL: 92.74 BOTTOM PUMP OFF EL: 92.32 la ' " A 1I PUMP CHAMBER 1 J- ELEV.= 91.32 - PROVIDE 2 FLOATS: FLOAT NOA: PUMP ON/OFF-SJ RHOMBUS (PR( FLOAT NO.2: ALARM ACTIVATION FLOAT-PROVII (ON SEPARATE CIRCUIT FROM NEMA 4 JUNCTION BOX CORROSION RESISTANT ISER WITH & LIQUID -TIGHT CABLE CONNECTORS SUPPORTED ,DE BY 1-1/4" PVC CONDUIT. JOINTS TO BE MADE WATERTIGHT. AN SJE RHOMBUS-JB PLUGGER OR EQUAL IS RECOMMENDED. PROVIDE ENOUGH WIRE 12'-2" F SLACK TO REMOVE PUMP I i I 1 INSTALL 1' PVC CONDUIT TO HOUSE FOR WIRING WITH WATERTIGHT JOINTS. WIRE HIGH WATER ALARM FLOAT TO SJE RHOMBUS TANK ALERT XT ALARM PANEL`4 ON CIRCUIT SEPARATE FROM CIRCUIT TO THE PUMP. 6' 2" BALL VALVE (FIELD ADJUST FOR 20 GPM RATE) (INSTALL QUICK. DISCONNECT FOR EASY REMOVAL) 2"SCH. 40 DISCHARGE (THROUGH RISER -SEE PROFILE) 2" 90" ELBOW W/ 1/4" WEEP HOLE j FOR SELF -DRAINING FORCE MAIN l L 2" SWING CHECK VALVE _ - -u___ 2" SCH. 40 PVC DISCHARGE PIPE 4" KNOCKOUTS PLAN VIEW ADDITIONAL 3/16- VENT HOLE (MIN.) ABOVE PUMP FLANGE (TYR) 4� (TO PREVENT PREMATURE PUMP BURNOUT) :D WITH PUMP) LIBERTY LE40 SERIES PUMP .4 H.P. 115 V 4"(8- H-20) 20" DIA. COVERS WITH ALARM PANEL WITH DISCHARGE, OR EQUAL I (TYP) 1P SPECIFIED) ,2' - 1 PUMP CH MBER, .PUMP & ACCESSORIES AVAILABLE AS A UNIT CAPE WIN TER WORKS CO., HYANNIS, MA. (508) 862-0166 NOTE: APPROVED ALTERNATE MAY. BE SUBSTITUTED. PUMP DETAIL N.T.S. CULTEC CONTACTOR FIELDORAIN C-4(HD MODEL FD C-4 R STARTER RIB LARGE RIB ^WL1�1IBSMAALLL dl�1 MODEL FD C-4 E MIDDLE/END SMAALLL RIB LARGE RIB nAP IB A lkll �U � 4" DIA. 3" 8 5" CULTEC CONTACTOR FIELD DRAIN 0-4 CHAMBER STORAGE = 4" DIA. INSPECTION PORT M RIB I LARGE 12" CULTEC, Inc. PH: (203) 775-4416 0MT1 CULT C Contactor® and Rechar er® P.O. Box 280 PH: (800) 4-CULTEC 9 878 Federal Road FX: (203) 77,CUL 62 Plastic eptic and Stormwater Chambers Brookfield, CT 06804 USA www.cultec.com CULTEC BUOYANCY CALCULATIONS H-10 SEPTIC TANK/PUMP CHAMBER BOTTOM OF UNIT EL.= 91.32 HIGH GROUNDWATER EL.=92.6 BUOYANCY FORCE PER FOOT OF DEPTH: 12.2' x 6.7' x 1' x 62.4 Ibs./cu.ft. = 5100.6 Ibs. MAX. DISPLACEMENT = 92.60 - 91.32 = 1.28' MAX. UPLIFT PRESSURE = 1.28'x5100:6 Ibs/ft=6528.8 :Ibs. WEIGHT OF UNIT EMPTY = 18,852 Ibs. 18,852 Ibs > 6529 Ibs O.K. DOSING & STORAGE REQUIREMENTS DESIGN FLOW: 330 GPD (DAILY FLOW=220 GRID) DOSING REQUIRED: 6 CYCLES/DAY (SAND) 330 - 6 = 55.0 GALLONS/CYCLE DISTANCE REQUIRED BETWEEN PUMP ON AND PUMP OFF FLOATS: 55.0 GAL/CYCLE _ 125 GAL/FT = 0.44 FT/CYCLE (SAY 5") STORAGE. REQUIRED ABOVE WORKING LEVEL: 330 GALLONS STORAGE PROVIDED: INV.(IN) EL: 96.65 - PUMP ON EL: 92.74 = 2.91' STORAGE PROVIDED = 2.91' x 125. GAL/FT = 363.8 GALLONS 5'-8' 4" OUTLET 4" INLET.KN (6 '2" H-20) 4 KNOCKOUTS 3 4_3 r ': SUPPORT LIQUID (SEE NOTE (4'-5" H-20)`; COMPARTMENT:;:; BEAMS LEVEL I -.` AI I AVAll API (TYP) I CROSS SECTION A -A WT of H-10: 18,852 LBS. WT of H-20 24,721 LBS. SPECIFICATIONS 1.) CONCRETE 4,000 PSI AFTER 28 DAYS. 2.) CONSTRUCTION CONFORMS TO DEP TITLE V REGS. 310 CMR SECTION 15.226. 3.) TONGUE & GROOVE JOINT SEALED W/ BUTYL RESIN 4.) REINFORCEMENT PER ASTM C1227-96. 5.) ALSO AVAILABLE IN H-20 LOADING. 6) PRVIDE POLYMER WATERPROOF COATING DIA. COVERS I A I q,7„ 1. H- 4" (6" H-20) SEP a H-10 SEPTIC TANK/PUMP CHAMBER 1500/500 WIGGIN PRECAST CORP., BOURNE MA. (800) 564-6774 PROPOSED SEPTIC SYSTEM UPGRADE PLAN 57 ARROWHEAD DRIVE, YARMOUTH PORT, MA Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 02673 Engineers: Surveyors: SCALE DRAWN -, JOB. N0. Engineering Works, Inc. 8C Engineering, Inc. N.TS. P.T.M. 277-22 12 West Crossfield Rood 2854 Cranberry Hwy. Forestal le, MA 02644 E.Wareham, MA 02538 DATE CHECKED SHEET NO. (508) 477-5313 1 (508) 273-0377 9/3/22 P.T.M. 3 Of 3