Loading...
HomeMy WebLinkAboutEngineer PlanCDDH 103 78 PA DRIVEWAY k LOT 4 11,590±S.F. 100,25 102.96 ` 102.62 `N� + 100,39 103.12� 103.26 i \`s MHO SPIKE /T0.F.= 103.+ PATIO 3 9M SEWER CONNECTION-J INV.=101,8t(VERIFY) INSTALL CLEANOUT + 10330 �" [03.08 0 '�-w3 102 S 39'06'10"--AL m PROPOSED SEPTIC TANK EXISTING SEPTIC TANK — TOP = 102.74, INV.(IN)=101 TO BE PUMPED, CRUSHED AND FILLED PROPOSED S.A. —J 2-500 GAL CHA BERS SURROUNDED WITP STONE a 100.45 '1 y� , " PAVED ry 71 ` PK SET 100.00 dI Yarmouth 99,01 9934 EXISTING CESSPOOL TO BE REMOVED (SEE NOTE 71) 10 Of I, NAIL IEL.C--10000 SETT) PETER T. McENTEE --98-- EXISTING CONTOUR x 100.98 EXISTING SPOT GRADE —OHW-- OVERHEAD WIRES — G — EXISTING GAS SERVICE —W— EXISTING WATER SERVICE 0111 TEST PIT SEP 2 7 2022 IEALTH DEPT. 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED. BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER, 4. ANY CONDITIONS ENCOUNTERED DURING. CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. S. THERE ARE NO WELLS WITHIN 150' OF THE PROPOSED S.A.S. 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE DIRECTED BY THE APPROVING AUTHORITIES. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDESOF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY HEALTH DEPARTMENT PRIOR TO BACKFILL 13. THIS PLAN IS TO BE_USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY. o CIVIL N MAP ID: 50-139 No. 35109 .SYSTEM REcrS1E�\�'.Q PROPOSED SEPTIC UPGRADE PLAN 60 WOOD ROAD, SOUTH YARMOUTH, MA q 10'L � Prepared for: Dorothy Seward, 110 Chestnut Street, Apt 6, Waltham, MA OWNER OF RECORD Engineers: Surveyors: SCALE DRAWN JOB. N0. SEWARD, DOROTHY E Engineering Works, Inc. JCEngineering, Inc. 1"=20' P.T.M. 278-22 C/O ROBERT SEWARD 110 CHESTNUT ST, APT 6 12 West Crossfield Road Foreatdale, MA 02644 2854 Cranberry Hwy. E.Waroham, MA 02538 DATE CHECKED SHEET N0. WALTHAM, MA 02453 (508) 477-5313 (508) 273-0377 9/6/22 P.T.M. 1 Of 2 EXISTING SEPTIC TANK PROVIDE RISERS WITH COVERS OVER INLET & OUTLET MANHOLES SET TO 6" OG FINISH GRADE. .O.F.=104.0t-107.3t F.G. EL.=103.0t L=20' 0 S=1% (MIN.) 4"SCH40PVC INV.= 101.0E INSTAL RISER & COVER SETT 6" OF GRADE F.G. EL.=103.2t MEMO T_/ 10' DD GAS (MIN . ) 11 00.075 • • �• 1t _ 1�7�i1C�il:Pl i 101.8t(VERIFY) NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS, PRIOR TO INSTALLATION. 2) SEPTIC TANK & D—BOX SHALL BE SET LEVEL AND TRUE TO .GRADE ON A MECHANICALLY COMPACTED STABLE BASE OR 6" AGGREGATE BASE, AS SPECIFIED IN 310 CMR 15.221(2). 3) INSTALL INLET & OUTLET TEES AS REQUIRED. 4) A GAS BAFFLE SHALL BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF—TITE, ZABEL OR EQUAL. DESIGN CRITERIA F.G. EL.=101.5t L = 16' ® S=17 (MIN.) 4'SCH40 PVC NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL. 97.90 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. PROPOSED S.A.S. INSTALL RISER & COVER OVER ONE CHAMBER AND SET TO 3" OF F.G. TO SERVE AS INSPECTION PORT � F.G. EL.=101.0t -INV.=100.00 EFFECTIVE WIDTH = 11.8' INV.=97.40 2-500 GALLON LEACHING CHAMBERS SURROUNDED WITH STONE AS SHOWN H-20 RATED TOP CONC. ELEV.= 98.5t — BREA OUT ELEV.= 97.90 — INV. ELEV.= 97.40 — B0 OM ELEV.= 96.40- 4' OF NATURALLY OCCURRING PERVIOUS MATERIAL 5' A OVE GROUNDWATER NO GROUNDWATER, EL.=88.9 - SEPTIC SYSTEM PROFILE NUMBER OF BEDROOMS: 3 SOIL TEXTURAL CLASS: CLASS I (LOADING RATE=0.74 GPD/S.F.) DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 330 GPD DESIGN FLOW: 330 GPD GARBAGE GRINDER: NO —not allowed with design LEACHING AREA REQUIRED: (330 GPD) = 445.9 S.F. .74 GPD/S.F. PROPOSED SEPTIC TANK: 1500GALLON CAPACITY PROPOSED D—BOX: 1 INLET, 3 OUTLET (MINIMUM), H-20 RATE[ USE 2-500 GALLON LEACHING CHAMBERS IN SERIES SURROUNDED BY DOUBLE WASHED STONE ON ALL SIDES SIDEWALL AREA: 2(11.8' + 27.0') x 2 = 155.2 S.F. BOTTOM AREA: 11,8' x 27.0' = 318.6 S.F. TOTALAREA: ................... ......... .............................. 11473.8 S.F. DESIGN FLOW PROVIDED: 0.74 GPD/S.F.(473.8 S.F.) = 350.6 —2" LAYER OF 1/8' TO 1/2" DOUBLE WASHED STONE (OR APPROVED FILTER FABRIC) —3/4" TO 1-1/2" DOUBLE WASHED STONE EFFECTIVE LENGTH = 27.0' LEACHING SYSTEM SECTION 3/4- TO 1-1/2" DOUBLE WASHED STONE 3" LAYER OF 1/8" TO 1/2" DOUBLE WASHED STONE (OR .APPROVED FILTER FABRIC) SOIL LOG DATE: AUGUST 18, 2022 SOIL EVALUATOR: PETER McENTEE PE, SE-1542 WITNESS: JAY GARDINER HEALTH AGENT ELEV. T P DEPTH 100.4 o" FILL I t 98.6. 22" Ab LOOAMRY 4A2 SAND r1 98.1 B 28" SEI� 2:7 10YRY5/6 LOAM HEALTH D 97.4 C 36" PERC MED, SAND 2.5YR 6/6 88.9 1 1 138" PERC RATE <2 MIN/IN. ("C" HORIZON) NO GROUNDWATER ENCOUNTERED HOUSE(#60) 104.0E-1G co.r I j PROPOSED S.A.S. 2-500 GAL CHAMBERS SURROUNDED WITH STONE SEPTIC LAYOUT �11.999m,11111, t�1 1�f t�l 1 1 1 f 11 1t�lt�1 �11� 1=11�11�1 1 4" KNOCKOUT 20" DIA. COVER 4" KNOCKOUT O� 4" KNOCKOUT 4" KNOCKOUT 500 GALLON CAPACITY, H-20 LOADING CHAMBERS 58" PROPOSED SEPTIC SYSTEM UPGRADE PLAN 60 WOOD ROAD. SOUTH YARMOUTH. MA Prepared for: Dorothy Seward, 110 Chestnut Street, Apt 6, Waltham, MA Engineere: Surveyors: SCALE DRAWN JOB. NO. Engineering Works, Inc. JCEngineering, Inc. N.T.S. P.T.M. 278-22 12 West Crossffeld Rood Forestdole, MA 02644 2854 Cranberry Hwy. E.Worehom, MA 02538 [DATE CHECKED SHEET N0. (508) 477-5313 (508) 273-0377 /6/22 P.T.M. 2 of 2