Loading...
HomeMy WebLinkAboutReview Checklist ,, TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lot 0237 Zone of Contribution: In Out £Acreage7J ' 0 Commercial: Residential. `= Street: 4 Village: 1 Floor Plan: I/ • 1 � # Bedrooms:. ' Owner: - i.4 I J c/ 3 rc.,,V 4,t. Installer: i-- et 8 f'4'cr�~ Y C Address: \.. Phone: Phone: Builder: Engineer: Fet Address: _ Phone: Phone: I N/A YES NO 1. Required#of copies received 2. Date of soils exam and percolation test not older than 2 years • 3. 4-5 ft of naturally occurring pervious material, above water table 1/ 4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: I ../ 5. Water line 10 ft from septic components Var.: ✓ 6. Benchmark indicated and shown-NGVD if near wetlands ✓ t 7. Septic tank minimum 10 ft from foundation, deck Var.: S. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: L / 9. Leaching minimum 100 ft from wetlands Var.: I t. 10. Leaching minimum 150 ft from drinking we1L'25 ft irrigation well _ Var.: j 11. Tank/leaching minimum 10 ft from property line Var.: ; 12. System meets all other setback requirements Var.: ,,� 13. Uses adjustment for maximum high groundwater Var.: • 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: 15. System not in top or subsoil(A,B horizons) or 5' removal 16. Proposed contours are suitable 17. System meets slope requirements-min. 1i 8", !'"preferred 18. System meets breakout requirements PVC liner: Wall: i 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel 21. No garbage disposal 1 22. System adequately sized for its intended use 23. Minimum 6"stone or compacted below tank and dbox ✓ I 24. Manhole covers within 6"of grade, pump chamber cover to grade 25. Inspection port on plastic chambers/leach field 26. Electrical permit for pump chamber,-Separate meter for duplexes 27. Pump system-2" line,weep hole,check valve, tee in dbox,pump size f� 2S. Septic tank/pump chamber to be factory waterproofed 29. Vent provided if leaching below 3 feet,under driveway/parking 1'� f ___ 30. Buoyancy calculations for tank pump chamber L/ 31. Engineer to inspect and certify soils: wall: commercial: I 4/ 32. EngineerRegistered Sanitarian and Land Surveyor stamps/signature j 33. H-20 loading is subject to vehicular traffic, groundwater 1 34. Title V Application and permit fee, installer signature 35. Foundation footing min. 2 feet above adjusted ground water for new house It;a:/ 36 . Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/Label groundwater in Assessor's Map • Plan reviewed by: _ 074 ) 01 0'