Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. _2t, Lot r;30 Zone of Contribution: In Out '✓Acreage D./� Commercial: Residential: Street: �-.e- Village: Floor Plan: Bedrooms: Owner: i .e., Va yr LJ 2 i r�/...) Installer: B f 3 Address: Phone: Phone: Builder: Engineer: /6A.e,r1 Address: Phone: • Phone: NIA YES I NO 1 1. Required#of copies received ✓ 2. Date of soils exam and percolation test not older than 2 years I :, __ 3. 4-5 ft of naturally occurring pervious material, above water table 4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5. Water line 10 ft from septic components Var.: 6. Benchmark indicated and shown-NGVD if near wetlands v- 7. Septic tank minimum 10 ft from foundation, deck Var.: e----- 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9. Leaching minimum 100 ft from wetlands Var.: i 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: a� i 11. Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: 13. Uses adjustment for maximum high groundwater Var.: 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: ✓ 15. System not in top or subsoil(A,B horizons)or 5' removal _ I ! -- 16. Proposed contours are suitable 17. System meets slope requirements-min. 1/8", `,%<"preferred 18. System meets breakout requirements PVC liner: Wall: 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel ' �/ 21. No garbage disposal ,4 �/ 22. System adequately sized for its intended use I 23. Minimum 6"stone or compacted below tank and dbox I / j 24. Manhole covers within 6"of grade, pump chamber cover to grade _25. Inspection port on plastic chambers/leach field t-I 26. Electrical permit for pump chamber/Separate meter for duplexes • - 27. Pump system-2"line,weep hole,check valve, tee in dbox,pump size ./ 28. Se tic tank/pump chamber to be factory waterproofed / 29. Vent provided if leaching below 3 feet,under driveway/parking 30. Buoyancy calculations for tank/pump chamber , / 31. Engineer to inspect and certify soils: wall: commercial: 18✓ e 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature j 1 V I 33. H-20 loading is subject to vehicular traffic, groundwater 34. Title V Application and permit fee, installer signature 35. Foundation footing min..2 feet above adjusted ground water for new house i 'Io 36. Deed Restriction required max. #bedrooms: max. flow: gpd f 37. Check area lots for groundwater/Label groundwater in Assessor's Map ' Iv Plan reviewed by: _ '- / - 27 40'0;