Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. 3 a Lot f Zone of Contribution: In Out Acreage �j 6 O tJ / / N\ b // R C Commercial: Residential: Street: `� � Village: l Floor Plan: r #Bedrooms: 0 Owner: Installer:Co P e L 6,1 &P1; C. cc--r 1,l'el rs Address: _ Phone: Phone: Address:Bud lder: Engineer: �N c,I I., c t� % 1 Phone: Phone: N/A YES NO 1. Required#of copies received V 2.Date of soils exam and percolation test not older than 2 years 3.4-5 ft of naturally occurring pervious material,above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5.Water line 10 ft from septic components Var.: '_ 6. Benchmark indicated and shown-NGVD if near wetlands 4� 7. Septic tank minimum 10 ft from foundation, deck Var.: 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: t� 9. Leaching minimum 100 ft from wetlands Var.: 1 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: r/, 11.Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: 1/ 13. Uses adjustment for maximum high groundwater Var.: 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.` 15. System not in top or subsoil(A,B horizons)or 5' removal Z 16.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", Y."preferred 18. System meets breakout requirements PVC liner: Wall: <,..„ 19. Specified tee sizes are proper, gas baffle on outlet tee / 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal ,--- 22. System adequately sized for its intended use L� 23.Minimum 6"stone or compacted below tank and dbox G� 24. Manhole covers within 6"of grade,pump chamber cover to grade 25. Inspection port on plastic chambers/leach field 26. Electrical permit for pump chamber/Separate meter for duplexes ! L/ 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size 28. Septic tank/pump chamber to be factory waterproofed 29. Vent provided if leaching below 3 feet,under driveway/parking 30. Buoyancy calculations for tank/pump chamber 31. Engineer to inspect and certify soils: wall: commercial: „/ 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic,groundwater 34.Title V Application and permit fee, installer signature 35.Foundation footing min.2 feet above adjusted ground water for new house / 36.Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by_ 60301 /0 ' � '� 2