HomeMy WebLinkAboutBLDE-22-006175 PLANS SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION •SYSTEM SIZE:5440W DC,3800W AC •ALL WORK SHALL COMPLY WITH MA 9th Ed.CMR 780(2015 IRC/IBC/IEBC), SOLAR MODULES PV-1.0 COVER SHEET •MODULES:•INVERTERS:(1) TECHNOLOGIES: INSTRUCTIONS. ) SOLAREDGE JA SOLAR:JA60S10-340/MR MUNICIPAL DE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION SERVICE ENTRANCE • Y p O q PV-2.0 SITE PLAN SE3800H-USS3 •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. I •RACKING:SNAPNRACK RLU;RL UNIVERSAL,SPEEDSEAL MP MAIN PANEL - PV-3.0 LAYOUT TRACK ON COMP,SEE DETAIL SNR-DC-00436 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. PV 4.0 ELECTRICAL •MAIN PANEL REPLACEMENT:EXISTING 100 AMP MAIN ---n.. • n PANEL WITH 100 AMP MAIN BREAKER TO BE REPLACED •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP SUB-PANEL SNR MOUNT PV-5.0 SIGNAGE WITH NEW 200 AMP MAIN PANEL WITH 200 AMP MAIN GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. SNR MOUNT&SKIRT BREAKER. •NEW 200A MAIN BREAKER FOR THE NEW 225A SUB PANEL •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER TO BE INSTALLED. L tip'' CHIMNEY •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. ATTIC VENT •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER j FLUSH ATTIC VENT MODULES,ARE CLASS A FIRE RATED. .. PVC PIPE VENT •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) C6 METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). x T-VENT •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). O AC DISCONNECT(S) (7' SATELLITE DISH •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC 1=I DC DISCONNECT(S) FIRE SETBACKS •10.46 AMPS MODULE SHORT CIRCUIT CURRENT. •16.34 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)&690.8(b)). O CB 10 COMBINER BOX H. - HARDSCAPE •PV INSTALLATION COMPLIES WITH THE NEC 2017 ARTICLE 690.12(B)(2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY AREEINTERIOR EQUIPMENT —PL— PROPERTY LINE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION L J SHOWN AS DASHED SCALE:NTS A PERE AC ALTERNATING CURRENT s u n r u n AFC' ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION #180120 DC DIRECT CURRENT (E) EXISTING 605 MYLES STANDISH BLVD,TAUNTON,MA,02780-7331 ESS ENERGY STORAGE SYSTEM HONED 0 EXT EXTERIOR INT INTERIOR CUSTOMER RESIDENCE: - MAG MAGNETIC JOAN RUSSELL 's u e n .c MSP MAIN SERVICE PANEL 24 ANGUS AVE,YARMOUTH,MA, •'Ci (N) NEW 02664 Q NTS NOT TO SCALE OC ON CENTER TEL.(732)804-6838 - PRE-FAB PRE-FABRICATED APN:YARM-000033-000043 R PSF POUNDS PER SQUARE FOOT BER: 1. T NUM PV PHOTOVOLTAIC PROJECT 4NU1 RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS DESIGNER: (415)580-0920 ex3 TYP TYPICAL 9 ' V VOLTS EMYLEYACUB 0 W WATTS SHEET r_ REV NAME DATE COMMENTS COVER SHEET T. REV:A 4/18/2022 e•RJ d£ N0„,, PAGE PV-1.0 T .0 e -4"e. LSE - Z - Co 17,S 2 1 . SITE PLAN-SCALE=3/32"=1'-0" ARRAY TRUE MAG PV AREA PITCH AZIM AZIM (SOFT) tN \ AR-01 30° 249° 263° 289.7 (E)RESIDENCE N. / - e- (N)ARRAY AR-01 1. 1114 ck \----.'''.... lag Ira Irik 1111 \\ 11111 / \ sunrun 11 7 \ ,,'- #180120 GN / f`-1 ,,,,,,--- `J A 74 / i�sorvE o s STAND.BLVD,TAUNTON,MA,02780,31(n ,.___/-'a FAX 0 a a° A CUSTOMER RESIDENCE: JOAN RUSSELL C q n G \ 24 ANGUS AVE,YARMOUTH,MA, PS- ,� a e J 02664 %, TEL.(732)804.6838 APN:YARM-000033-000043 d ° PROJECT NUMBER: 0' SSP 223R-024RUS1 ® MPO PM INV DESIGNER: (415)580-6920 ex3 1 e. EMYLE YACUB SHEET 0- SITE PLAN REV:A 4/18/2022 PAGE PV-2.O ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Max OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF Name Type Height Type Span Spacing Detail OC Spacing Overhang OC Spacing Overhang Configuration SNOW LOAD:30 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 16'-1" 16" 4'-0" 2'-0" STAGGERED 140 MPH 3-SEC GUST. COMP,SEE DETAIL SNR-DC-00436 5'-4" 2'-1" S.S.LAG SCREWS: D1-AR-01-SCALE:3/16"=1'-0" 5/16":2.5"MIN EMBEDMENT AZIM:249° STRUCTURAL NOTES: • INSTALLERS SHALL NOTIFY PITCH:30° ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. STRUCT ; • IF ARRAY(EXCLUDING SKIRT) ONL C �� S50F/4,_9 IS WITHIN 12"BOUNDARY REGION OF ANY ROOF PLANE VINCENT x, EDGES(EXCEPT VALLEYS), MWUMVANEZA m THEN ATTACHMENTS NEED 22' "_.._—___ ___— __, _ _t0'-2 __y CIVIL TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" 1-6 9l'` GA���e FOLLOWSY REGION ONLY AS ••ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY = = mum= = : : .-_., 50% ••ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE 13'-3" _ _ _ ATTACHMENT SPACING ,. rillE ,mIllu= INDICATED ON PLANS mim. 111.111 MIIII sunrun 3-Y, #180120 } BBB MYLES STAND.BLVD,TAUNTON,MA,02780-7331 ONE 0 FM 0 CUSTOMER RESIDENCE: JOAN RUSSELL 24 ANGUS AVE,YARMOUTH,MA, 02664 TEL.(732)804-6838 APN:YARM-000033-000043 PROJECT NUMBER: 223R-024RUS1 DESIGNER: (415)580-6920 ex3 EMYLE YACUB SHEET LAYOUT REV:A 4/18/2022 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 • L . 120240 VAC SINGLE PHASE SERVICE METER N: < O EVERSOURCE 2289548 UTILITY NOTE:TOTAL PV BACKFEED=20A USED FOR INTERCONNECTION GRID CALCULATIONS /I NEW200A MAIN 1\ DISCONNECT WITH I 200A ENCLOSURE „.-LOAD SIDE TAP /. SOLAREDGE TECHNOLOGIES: (N)LOCKABLE SE3800H-US IMTH REVENUE (I NEW 200A SUB BLADE TYPE (N)MA SMART GRADE METERING(PN MAIN BREAKER FUSED AC UTILITY SE3800H-USS3),3800 WATT I DISCONNECT REVENUE INVERTER METER /'� 3800 WATT INVERTER JUNCTION BOX ��'� PV MODULES �' NEW 225A SUB `/ OR EDUNALENT AJA SOLAR:JAM60S10-310/MR �--- A A/ /, (16)MODULES �\ PANEL _„I,_ ,o, O Ji ✓` _ �� �_ VI '�/ OPTIMIZERS WIRED IN: FACILITY (1)SERIES OF(8)OPTIMIZERS LOADS 20A FUSES I I (1)SERIES OF(8)OPTIMIZERS �o�7. SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT D221NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN L SOLAREDGE POWER OPTIMIZERS 3R,30A UTILITY SIDE OFCIRCUR COMPLIANT P370 120240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n r u n 3 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 60S MYLES STANDISH BLVD,TAUNTON.MA.02780-7. PHONE CUSTOMER RESIDENCE: MODULE CHARACTERISTICS JOAN RUSSELL JA SOLAR:JAM60S10-340/MR: 340 W P370 OPTIMIZER CHARACTERISTICS: 24 ANGUS AVE,YARMOUTH,MA, MIN INPUT VOLTAGE 8 VDC OPEN CIRCUIT VOLTAGE: 41.55 V 02664 MAX INPUT VOLTAGE: 60 VDC MAX POWER VOLTAGE: 34.73 V MAX INPUT ISC: 11 ADC SHORT CIRCUIT CURRENT: 10.46 A MAX OUTPUT CURRENT: 15 ADC TEL.(732)804-6838 APN:YARM-000033-000043 PROJECT NUMBER: SYSTEM CHARACTERISTICS-INVERTER 1 223R-024RUS1 SYSTEM SIZE: 5440 W SYSTEM OPEN CIRCUIT VOLTAGE: 8 V DESIGNER: (415)580-6920 ex3 SYSTEM OPERATING VOLTAGE: 380 V EMYLE YACUB MAX ALLOWABLE DC VOLTAGE: 480 V SYSTEM OPERATING CURRENT: 14.32 A SHEET SYSTEM SHORT CIRCUIT CURRENT: 30 A ELECTRICAL REV:A 4/18/2022 PAGE PV-4.O t INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE. 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS. SIDES MAY BE ENERGIZED IN •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING THE OPEN POSITION LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2020:690.53 INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI 2535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2020:690.13(B) WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020:690.31(0)(2),IFC 2012: SYSTEM 605.11.1.4 LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S):NEC 2020.705.12(C) 7-1 DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: INSTALLED WITHIN 3'OF RAPID SHUT DOWN LABEL LOCATION: SWITCH PER CODE(S):NEC 2020:690.56(C((2(,IFC $U n r U n ADJACENT TO PV BREAKER AND ESS 2012:605.11.1,IFC 2018:1204.5.3 OCPD(IF APPLICABLE). PER CODE(S):NEC 2020: 705.12(B)(3))2) -.- . SOLAR PV SYSTEM EQUIPPED- PHOTOVOLTAIC SYSTEM WITH RAPID SHUTDOWN 513S MALESsrnNoisHewo,TAUNTON Mn,os eo-w COMBINER PANEL veoueo FAY o DO NOT ADD LOADS CUSTOMER RESIDENCE: LABEL LOCATION: JOAN RUSSELL PHOTOVOLTAIC AC COMBINER(IF 24 ANGUS AVE,YARMOUTH,MA, APPUCABLE). 02664 PER CODE(S):NEC 2020:705,12(D)(2)(3)(c) 3 TURN RAPID SHUTDOWN SWITCH TO THE"OFF" VW TEL.(732)804-6838 MAMMPOSITION TO SHUT DOWN APN:YARM-000033-000043 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE PROJECT NUMBER: SHOCK HAZARD IN THE MAXIMUM AC OPERATING CURRENT'15.83 AMPS ARRAY. 'I ) 223R-024RUS1 NOMINAL OPERATING AC VOLTAGE. 240 VAC DESIGNER: (415)580-6920 ex3 LABEL LOCATION: EMYLE YACUB AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S):NEC 2020:690.54 LABEL LOCATION: SHEET ON OR NO MORE THAT 1 M(3 Fl)FROM THE SERVICE S I G NAG E DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV:A 4/18/2022 PER CODE(S):NEC 2020:690.56(C) PAGE PV-5.0